Assembly see page 31
Cleaning
see enclosed brochure.
Operation
(see page 35)
Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a prolonged
period of non-use.
Spare parts
(see page 36)
Flow diagram
(see page 34)
Dimensions
(see page 34)
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 33. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
English
Test certificate
(see page 36)
4
Summary of Contents for Focus 31825000
Page 31: ...31 5 1 3b 2 4 3a 1 2 1 2 Silicone 1 2 min 34 mm max 39 mm max 5 mm ...
Page 32: ...32 6 7 SW 30 mm 17 Nm SW 22 mm 2 min SW 22 mm 2 Nm 10 11 12 8 9 2 1 30 Ncm ...
Page 33: ...33 2 1 3 4 5 6 7 60 C 10 C 0 3 MPa 0 3 МПа 0 3 ﻣﻴﺠﺎﺑﺴﻜﺎل ...
Page 34: ...34 Focus 31825000 Focus 31825000 19 24 61 165 195 261 ...