8
9
1
2
32 - 41
mm
Seal
Shower Thermostat
PTFE
tape
3
150 mm
HOT
COLD
Shower Thermostat
1. The hot and cold water outlets should be 150mm
apart (plus or minus 12mm). Hot on the left and
cold on the right (fig. 1). The recommended
plumbing fittings are 1⁄2“ back plate elbows (not
supplied).
2. Flush through the hot and cold water supplies.
3. Wrap PTFE tape round the S-unions and screw
into the backplate elbows. The S-unions must
protrude beyond the tiled surface between 32
and 41mm (figs.2-3).
4. Seal the gap between the S-unions and the tiles
(fig.3).
5. Screw the escutcheons onto the S-unions.
6. Fasten the thermostatic mixer onto the S-unions
using the union nuts. Align the unit and tighten
the nuts (be careful not to damage the chrome
finish). The S-unions allow inaccuracies to be
compensated for.
Installation
Bath/Shower Thermostat
As the shower thermostat above (positioned over
a bath).