Hans Grohe Ecostat 1001 SL Care 13284000 Installation Instructions Manual Download Page 16

16

Trouble Shooting 

Fault                                     Cause                                   Remedy

Insuffient water flow                     Supply pressure inadequate          Check mains pressure 

                                                 Shower filter seal dirty                  Clean filter seal between shower  

                                                                                                  and hose

                                                 Thermostat cartridge filters dirty     Remove cartridge & clean

                                                                                                  the filters on the barrel

‚Crossflow‘, hot water is forced     check valves dirty or                     Clean check valves -

into cold water pipe, or vice         leaking                                       replace if necessary 

versa

Spout temperature does not          Thermostat has not been               Calibrate thermostat 

correspond wlth the temperature    adjusted 

set 

                                                 Hot water temperature too low      Increase hot water temperature 

No temperature control                Thermostat cartridge failure or       Check/clean filters 

                                                 blocked filters                              Replace cartridge 

Shower or spout dripping             Dirt in the flow valve or ‚shut off‘    Clean or replace shut-off unit 

                                                 unit damaged 

Warranty 

You have purchased a quality product from Hansgrohe. All parts which show any kind of fault as far as 

construction, material or assembly are concerned within the first 24 months after installation, we will repair 

or exchange the part in question free of charge. Faulty items become our property. 

We do not grant warranty for faults caused by:

     unsuitable or improper use; incorrect assembly; installation started and/or completed by a non-qualified 

plumber, natural wear out, improper or careless treatment, lack of maintenance; unsuitable usage; 

chemical, electro-chemical or electrical influences.

07/2006 9.04210.01

Hansgrohe · Units D1 & D2 Sandown Park · Trading Estate Royal Mills · Esher Surrey KT10 8BL · Technical Hotline 0870 770 1975 

E-Mail: [email protected] · Internet: www.hansgrohe.com

Summary of Contents for Ecostat 1001 SL Care 13284000

Page 1: ...Installation Instructions Ecostat 1001 SL Care 13282000 Ecostat 1001 SL Care 13284000...

Page 2: ...e tests 10 Frequency of in service tests 10 Thermostatic Adjustement Temperature Limitation 11 Operating your Shower 12 Cleaning 13 Spare Parts 14 15 Trouble Shooting 16 The Ecostat 1001 SL Care 13284...

Page 3: ...ustry Approved Plumber Scheme WIAPS Dispose of plastic bags carefully Keep children well away from the work area Check for hidden pipes and cables in the wall before drilling holes The unit must be mo...

Page 4: ...ith the following Ecostat 1001 SL Care 13282000 1 Ecostat 1001 SL 3 Escutcheons 2 Mesh washers 4 S unions 1 2 3 4 Ecostat 1001 SL Care 13282000 Ecostat 1001 SL Care 13284000 1 Ecostat 1001 SL 3 Escutc...

Page 5: ...emperature C 52 to 65 52 to 65 Cold supply temperature C 5 to 20 5 to 20 Mixed water temperature Application Mixed water temperature at point of discharge Bidet 38 C max Shower 41 C max Washbasin 41 C...

Page 6: ...int 1 0 10 bar Unvented System pressure balanced 1 0 10 bar Pumped System 1 0 10 bar IMPORTANT If you install this mixer with a gravity fed system there must be a minimum head vertical distance from t...

Page 7: ...7 Unvented System pressure balanced Pumped System...

Page 8: ...tape round the S unions and screw into the backplate elbows The S unions must protrude beyond the tiled surface between 32 and 41mm figs 2 3 4 Seal the gap between the S unions and the tiles fig 3 5...

Page 9: ...e mixed water in accordance with the manufacturer s instructions and the requirement of the application and then carry out the following sequence a record the temperature of the hot and cold water sup...

Page 10: ...nce of any other instruction or guidance on the means of determining the appropriate frequency of in service testing the following procedure may be used 1 6 to 8 weeks after commissioning carry out th...

Page 11: ...he spindle and slide off the locking ring fig 1 2 Turn the spindle until the required maximum temperature is reached 43 C You will need to use a thermometer fig 2 3 Replace the locking ring back onto...

Page 12: ...1001 SL Care Flow ON OFF Control Shower Turn the flow control handle fig 2a anti clockwise to turn the water on and to increase the flow for the shower outlet Turn it clockwise to decrease the flow a...

Page 13: ...ing Instructions for Mixers and Showers Please follow the cleaning materials manufacturer s inistructions In addition pay attention to tlie following points Clean the mixers and showers as and when re...

Page 14: ...ement 94282000 2 Shut off and diverter unit 96509000 3 Handle for shut off and diverter unit and temperature control 98664000 4 Check valve NV15 DN15 96737000 5 S unions 94140000 6 Escutcheon 96467000...

Page 15: ...DN15 1 Thermostatic element 94282000 2 Shut off unit 94149000 3 Handle for shut off unit and temperature control 98664000 4 Check valve NV15 DN15 96737000 5 S unions 94140000 6 Escutcheon 96467000 7...

Page 16: ...r or spout dripping Dirt in the flow valve or shut off Clean or replace shut off unit unit damaged Warranty You have purchased a quality product from Hansgrohe All parts which show any kind of fault a...

Reviews: