![Hans Grohe Ecostat 1001 SL Care 13284000 Installation Instructions Manual Download Page 5](http://html1.mh-extra.com/html/hans-grohe/ecostat-1001-sl-care-13284000/ecostat-1001-sl-care-13284000_installation-instructions-manual_4731503005.webp)
4
5
Technical Data
Ecostat 1001 SL Care
This thermostatic valve will suit supplies of:
HIGH PRESSURE (HP-S)
Operating pressure: max. 10 bar
Recommended operating pressure: 0.2 - 5 bar
Test pressure: 16 bar
Hot water temperature: max. 80°C
Recommended hot water temp.: 65°C
Rate of flow from bath spout: 20 l/min. @ 3 bar
Rate of flow from shower outlet:18 l/min. @ 3 bar
Maximum outlet temperature: 43°C +/-*
Safety check: 40°C
Hot water connection: Left hand
Cold water connection: Right hand
Minimum difference between hot
water and mixed water temperature: 6 K
Hot and cold supply pressure should be balanced
Operating pressure range High pressure Low pressure
Maximum static pressure - bar 10 10
Flow pressure, hot and cold - bar 1 to 5 0.2 to 1
Hot supply temperature - °C 52 to 65 52 to 65
Cold supply temperature - °C 5 to 20 5 to 20
Mixed water temperature
Application Mixed water temperature
(at point of discharge)
Bidet 38°C max.
Shower 41°C max.
Washbasin 41°C max.
Bath (44°C fill) 44°C max.
Bath (46°C fill) 46°C max.
* For preset outlet temperature adjustment – See
page 9 „Commisioning“.
NB.
If a water supply is fed by gravity then the
supply pressure should be verified to ensure the
conditions of use are appropriate for the valve.
Valves operating outside of these supply conditions
cannot be guaranteed to operate as a TMV2 or
TMV3 valve.
Supply Conditions TMV2
Supply Conditions TMV3
Operating pressure range High pressure Low pressure
Maximum static pressure - bar 10 10
Flow pressure, hot and cold - bar 1 to 5 0.2 to 1
Hot supply temperature - °C 55 to 65 55 to 65
Cold supply temperature - °C 5 to 25 5 to 25
The following models are TMV3 approved for high
pressure shower (HP-S) application: 13282000