6
Safety Notes
6
Gloves should be worn during installation to prevent crushing and cutting
injuries.
6
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
6
Children as well as adults with physical, mental and/or sensoric impairments
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
6
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
6
The product may not be used as a holding handle. A separate handle must be
installed.
6
The shower system may only be used for bathing, hygienic and body cleansing
purposes.
6
The hot and cold supplies must be of equal pressures.
Installation Instructions
• The fitting must be installed, flushed and tested after the valid norms.
• The installation dimensions stated in this installation instructions are ideal for peo-
ple of approximately 1800 mm in body height. The dimensions can be altered if
required. In this case you will have to attend to the minimum height of 2350 mm
from shower tray floor, and alter all the required measurements as necessary.
• Where the contractor mounts the product, he should ensure that the entire area of
the wall to which the mounting plate is to be fitted, is flat (no projecting joints or
tiles sticking out), that the structure of the wall is suitable for the installation of the
product and has no weak points. The enclosed screws and dowels are only sui-
table for concrete. For another wall constructions the manufacturer’s indications
of the dowel manufacturer have to be taken into account.
• The premounted filter insert must be used to ensure a normal flow of the shower
and to prevent dirt from entering through the pipes. Dirt entering can affect the
function and/or lead to damages to the shower. Hansgrohe will not be held
liable for this type of damage. (see page 33).
• If required, the bottom part of the pipe between the fixture and the shower head
can be shortened with a fine-toothed saw.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Centre distance:
150 mm
Connections G 1/2:
cold right - hot left
anti-pollution function
English
Maintenance
(see page 35)
The non return valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least once
a year).
Operation
(see page 36)
Flow diagram
(see page 31)
overhead shower
Hand shower
Assembly see page 32
To adjust the hot water limiter on single lever mixers, please see page
34. No adjustment is necessary when using a continuous flow water
heater.
Do not use silicone containing acetic acid!
Symbol description
Dimensions
(see page 31)
Cleaning
(see page 37) and enclosed brochure
Test certificate
(see page 39)
Fault
Cause
Remedy
Insufficient water
- Shower filter seal dirty
- Clean filter seal between shower and hose
- Non return valve hasn't moved back
- Exchange non return valves
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Instantaneous heater didn’t work
- Filters are dirty
- Clean the filter / exchange filter
- Non return valve hasn't moved back
- Exchange non return valves
- Flow limiter in handshower isn’t removed
- Remove flow limiter
4
Summary of Contents for Citterio Showerpipe
Page 31: ...31 Citterio Showerpipe 39620000 Citterio Showerpipe 39620000 ...
Page 32: ...32 1 1 2 2 3 4 5 6 1 2 SW 5 mm 1 2 Silikon 7 10 8 9 150 2 1 SW 27 mm ...
Page 33: ...33 B A 12 15 14 16 17 13 11 S i l i k o n SW 3 mm 1 2 SW 2 mm 18 19 20 ...
Page 34: ...2 1 3 4 5 6 7 60 C 10 C 0 3 MPa 0 3 МПа 0 3 ﻣﻴﺠﺎﺑﺴﻜﺎل 34 ...
Page 35: ...2 1 35 ...
Page 37: ...37 1 2 3 2 1 3 4 1 min 1 min 5 ...
Page 39: ...39 PA IX DVGW SVGW WRAS KIWA NF ACS 39620000 X X ...