Cleaning
(see page 39) and enclosed brochure
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The shower system may only be used for bathing, hygienic and body cleaning
purposes.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
Do not allow the streams of the shower touch sensitive body parts (such as
your eyes). An adequate distance must be kept between the shower and you.
Electrical connection
The installation and testing work must be performed by a skilled electrician in
observance of VDE 0100 part 701 and IEC 60364-7-701.
The current version of the applicable regulations from VDE, local authorities
and utility companies must be observed for electric installation work.
The entire power is supplied via a 230V/N/PE/50Hz AC connection.
The system must be protected via a leakage current protective device (RCD/
FI) with a measurement difference current of ≤ 30 mA.
The proper function of this fusing/protection must be checked at regular
intervals.
The ambient temperature must not be higher than 50ºC.
It must be ensured that the product can be disconnected from the mains, e.g.
via a an all-pin switch as per EN 60335-1, sect. 24.3
The transformer must not be installed in protection zones 0, 1 or 2.
transformer
The voltage supply from the 12 V DC SELV must only be fed via the included
transformer type 19769610. The transformer must be installed safe from
outside contact outside the zones 0, 1 and 2 in a flush-type box to be provided
by the customer. (see page 32)
The transformer must be installed inside the wall in a > Ø 60 mm socket. This
socket inside the wall is connected to the overhead shower via an empty
conduit EN 20. (see page 38 Fig. 11)
The mains voltage of 100 - 240 V AC 50 - 60 Hz must be supplied via a
existing shutoff device (switch) as well as a ground fault protector (RCD / FI)
with a measured differential current of ≤ 30 mA.
The transformer type19769610 is only suited for the voltage supply of the
product 26031000.
A different or excessive use is considered non-intended. (The user/operator bears
the sole risk.) The intended use includes the adherence to the operating instructions
and the observance of the inspection and maintenance guidelines. The manufactu-
rer/seller of this product does not assume any responsibility for injuries or damage
that may be caused by improper installation or non-intended use.
Installation Instructions
• The pipes and the fixture must be installed, flushed and tested as per the appli-
cable standards. (Installation to EN 1717)
• The plumbing codes applicable in the respective countries must be oberserved.
• During installation of the product by qualified trained personnel, make sure
that the entire fastening surface is even and smooth (no protruding seams or
tile offset), that the finish of the wall is suitable to apply the product and has no
weak points.
• Any work may only be carried out in a de-energized state.
• Pull the connecting line to light/transformer into the empty conduit by means of a
cable retractor (EN 20).
• Only standardized materials may be used for the installation.
• All components must remain accessible.
Technical Data
Operating pressure:
max. 0,6 MPa
Recommended operating pressure:
0,2 - 0,4 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Recommended hot water temp.:
42°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
transformer
Input (IN):
100 - 240 V / 50 - 60 Hz / 70 - 170 mA
Output (OUT):
12 V DC / 1 A
Protection class:
IP X1
Serial number:
26031000 (see typeplate)
Dimensions:
see page 32
weight:
81 g
The specifications are identical to the data on the type plate for the light and the
transformer.
Connecting cable between light/transform
Cable length:
7 m
Wire cross section:
approx. 0,25 mm²
- Wire color:
black (GND)
+ Wire color:
red (12 V DC)
Connection on the transformer:
Clamp connection
Empty conduit for cable:
EN20
If the connecting cable is shortened, it must be fitted with 0.25 mm² wire end plugs
and a contact length of 8 mm.
Illuminant change
• Any work may only be carried out in a de-energized state. Here, the voltage
supply must be safely separated via the main switch or mains plugs.
• The operator can perform the illuminant change.
• Order number:
98351000
• Illuminant change see page 41 Fig. 1 - 6
• All spare parts must be purchased at Hansgrohe or the sanitary dealer’s.
Symbol description
Do not use silicone containing acetic acid!
Dimensions
(see page 31)
Flow diagram
(see page 32)
Protected area
(see page 32)
12 V
Spare parts
(see page 44)
English
230 V
transformer
Empty pipe
Assembly with basic kit #26909180 see page 33
Assembly without basic kit see page 36
Summary of Contents for Axor Nendo
Page 31: ...31 12 7 G 1 2 428 113 115 14 0 2 2 9 565 275 380 3 0 5 5 90 75 75 7 5 7 5 115...
Page 33: ...33 SW 17 mm 20 mm 26909180 1 2 3 4 5...
Page 34: ...34 6 7 8 9 10 11 1 2 X 32 mm X SW 8 mm 8 mm 18 23 mm X 32 mm X...
Page 37: ...37 7 SW 10 mm 8 9 11 12 10 1 2 SW 10 mm...
Page 39: ...39 click 1 2 3 4 5 click 2 mm 2 mm...
Page 40: ...40 SW 4 mm SW 4 mm 4 Nm 3 1 2...
Page 42: ...42...
Page 43: ...43...