7
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
Children as well as adults with physical, mental
and/or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
Do not allow the streams of the shower touch sensitive
body parts (such as your eyes). An adequate distance
must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pressures.
Assembly
(see pages 34 to 37)
Important!
The fitting must be installed, flushed and
tested after the valid norms.
Important!
Do not use silicone containing acetic
acid!
Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels
are only suitable for concrete. For another wall
constructions the manufacturer’s indications of the
dowel manufacturer have to be taken into account.
The premounted filter insert must be used to ensure
a normal flow of the shower and to prevent dirt from
entering through the pipes. Dirt entering can affect
the function and/or lead to damages to the shower.
HansGrohe will not be held liable for this type of
damage.
In case of emergencies, the lower part of the pipe
can be shortened by means of a fine saw.
Optimal functioning is only guaranteed with the
combination of Hansgrohe hand showers and
Hansgrohe shower hoses.Shower hoses are only
suitable for a connection from the shower to the
fitting. Never fit a shut-off device between the fitting
and the hose.
•
•
•
•
•
•
•
•
•
•
•
•
•
English
Adjustment
(see page 38)
Correction is necessary if the temperature measured at
the take off point differs from the temperature set on the
scale.
Maintenance
To guarantee the smooth running of the thermostat, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
However, once a year the function of the non-
return-valve (8) has to be checked. At this time,
please also check the filter (6.1) situated on the
MTC-thermoelement (6). After assembling the MTC-
thermoelement, it is necessary to check the water
temperature at the take off point as described under
the headline „adjustment“. Before the adjustment,
please check, if the warm water supply is activated
and the maximum temperature of the warm water is
available at the take off point. (see page 38)
Technical Data
(see pages 2 to 4)
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80° C
Recommended hot water temp.:
65° C
Centre distance:
150 mm
Connections G 1/2:
cold right - hot left
anti-pollution function
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
Spare parts
(see page 40)
Operation
(see page 39)
Safety Function
(see page 42)
Cleaning
(see page 43)
•
•