11
Technical Data
This mixer series-produced with waterdim-
mer
®
(flow limiter).
Rate of flow with waterdimmer:
7 l/min 0,3 MPa
Rate of flow without waterdimmer: 14 l/min 0,3 MPa
Operating pressure:
max. 1,0 MPa
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1MPa = 10 bars = 147 PSI)
Hot water temperature:
max. 80° C
Recommended hot water temp.: 65° C
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled con-
tinuous flow heaters if the flow pressure is at least
0,15 MPa.
If the continuous water heater causes any problems or
there is not enough flow of water, the waterdimmer®
(7a) located behind the aerator must be removed.
To adjust the hot water limiter on single lever mixers,
please see page 19.
No adjustment is necessary when using a continuous
flow water heater.
Spare parts
(see page 4)
1 handle
34093000
1.1 screw cover
96762000
2 flange
98863000
3 nut
98864000
4 cartridge cpl.
97685000
5 seal
98865000
6 adapter for cartridge
98866000
7 aerator cpl.
98926000
8 pull rod
96657000
9 connection hose 470mm
96321000
connection hose 900mm
96316000
10 supply pipe 450mm
96638000
11 fixing set cpl.
13961000
12 ball joint
92036000
13 spray former cpl.
94005000
14 special tool
98987000
Special accessories
X special tool set
58085000
(order as an extra)
English
Fault
Cause
Remedy
Insufficient water
- Aerator calcified, dirty
- Waterdimmer
®
dirty or leaking
- Clean aerator, replace as neces-
sary
- Clean or exchange Waterdim-
mer
®
Mixer stiff
- Cartridge defective
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping bels ow handle
- Cartridge defective
- O-ring/rings defective
- Exchange cartridge
- Exchange O-ring/rings
Water escaping at the connection
hoses
- Connection hose defective
- O-ring at the connection hose
defective.
- Adapter for cartridge defective
- O ring of adapter for cartridge
defective
- Exchange connection hose
- Exchange O-ring
- Exchange adapteur pour cartou-
che
- Exchange O-ring
Hot water temperature too low,
no cold water.
- Hot water limiter incorrectly set - Set hot water limiter
Summary of Contents for AXOR Citterio M 34010000