IMPORTANT SAFETY INFORMATION 

 

The installation must conform with local codes or, in the absence of local codes, with the 
National Fuel Gas Code, ANSI Z223.1/NFPA 54; International Fuel Gas Code. ; Natural 
Gas and Propane Installation Code, CSA B149.1; or Propane Storage and Handling Code, 
B149.2, as applicable. 
 
The appliance must be isolated from the gas supply piping system by closing its 
equipment shutoff valve during any pressure testing of the gas supply system at test 
pressure equal to or less than 1/2 psi (3.5kPa). 
 
The appliance area must be kept clear and free from combustible materials, gasoline and 
other flammable vapors and liquids.   
 
Do not use this appliance if any part has been under water. Immediately call a qualified 
service technician to inspect the appliance and to replace any part of the control system 
and any gas control which has been under water. 
 

Children and adults should be alerted to the hazards of high surface temperatures 
and kept at a safe distance to avoid burns or clothing ignition. 
 
Young children should be carefully supervised when they are anywhere near the 
appliance.  
 
Clothing or other flammable material should not be hung from the appliance, or 
placed on or near the appliance. 
 
Any screen or guard removed for servicing an appliance must be replaced prior to 
operating the appliance. 
 
Installation and repair should be done by a qualified service person. The appliance 
should be inspected before use and at least annually by a professional service 
person. More frequent cleaning may be required as necessary. It is imperative that 
the control compartments, burners and circulating air passageways of the 
appliance be kept clean. 

 
Do NOT burn solid fuels in this gas fireplace. 
 

CAUTION

: The propane gas pressure regulator provided with this appliance must be 

used. This regulator is set for an outlet pressure of 11 inches water column. 
 
This outdoor gas appliance is not intended to be installed in or on recreational vehicles 
and/or boats. 
 
Before each use of this gas appliance, open the LP (Liquid Propane) Tank Drawer and 
inspect the LP Hose. If there is evidence of excessive abrasion or wear, or the hose is cut, 
it must be replaced prior to the gas appliance being put into operation. Use only the 
replacement hose assembly specified in this manual. Inspect the burner before each use 
of the appliance. The burner must be replaced prior to the appliance being put into 
operation if it is evident that the burner is damaged. Use only the burner listed in these 
instructions.  
 
Keep the fuel supply hose away from any heated surfaces. 

Summary of Contents for ORL4PCCFPSW2-TAN

Page 1: ...mer Service Hotline at 1 800 416 3511 Between 9 00 AM and 5 00 PM Eastern Time Monday through Friday Or visit our website at www hanover products com To expedite any future warranty claims please reta...

Page 2: ...adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment...

Page 3: ...or placed on or near the appliance Any screen or guard removed for servicing an appliance must be replaced prior to operating the appliance Installation and repair should be done by a qualified servi...

Page 4: ...s appliance shall be used only outdoors in a well ventilated space and shall not be used in a building garage or any other enclosed space When this appliance is not is use the gas must be turned off a...

Page 5: ...IFICE ELBOW FP0310 1 G IGNITION MODULE FP0006 1 H PROPANE ORIFICE ZCF0021 1 I AAA BATTERY 1 5V HW0705 1 J LAVA ROCK SET FP0002 1 K FOOTCAP FC0559 4 L 1 4 X 15 MM BOLT HW0034 8 M 1 4 X 20 MM BOLT HW003...

Page 6: ...6 U FIREPIT TABLE TOP 1 V BACK PANEL 1 W LEFT SIDE PANEL 1 X RIGHT SIDE PANEL 1 Y DOOR PANEL 1 Z MIDDLE SUPPORT 1 AA LP SUPPORT 1 BB BOTTOM TOP CONNECTOR 1...

Page 7: ...holes in the side panels Hand tighten only Figure 2 3 Attach the middle support to the side panels by using four 1 4 x15 mm bolts and washers as shown in Figure 3 Guide the bolts through the holes in...

Page 8: ...top connector to the right side panel as shown in Figure 5 Do not over tighten Figure 5 6 With the help of another person carefully place the table top onto the table base After making any necessary...

Page 9: ...gure 9 pre fitted with gas hose which is connected to the table top into the hole of the door panel then use hex bolt driver to screw 1 4 x5mm nut the gas tank has fixed as shown in Figure 9a Connect...

Page 10: ...en all bolts Note each bolt must be tightened a few revolutions at a time Repeat until all bolts are tight Do not over tighten Over tightening may strip bolts Cover all bolts with covers 12 Pour the l...

Page 11: ...is found close the tank valve and tighten all connections NOTE NEVER USE A FLAME TO CHECK FOR LEAKS BATTERIES Make sure the control knob is in the OFF position Unscrew the push button cap on the ignit...

Page 12: ...b should pop back out and then remain lit Note If the fire does not light turn the knob to the OFF position and wait five 5 minutes before trying again 3 To turn down the flame push the control knob i...

Page 13: ...dule Check that the electrode is not cracked or broken Burner won t light Lack of oxygen Remove excess lava rocks or fire ices from around the ignition well Thermocouple not in flame Check that the ti...