background image

 

5

PARTS IDENTIFICATION LIST

 

 

PART DESCRIPTION 

PART# 

QTY

 

CONTROL KNOB 

FP1245 

 

GAS VALVE 

FP0307 

 

THERMOCOUPLE

FP0004 1 

 

LP REGULATOR 

HOSE 

65-FP-0181 1 

 

ELECTRODE 65-FP-0128 

 

ORIFICE ELBOW 

FP0310 

 

IGNITION MODULE

FP0006 

 

PROPANE 

ORIFICE 

ZCF0021 1 

 

“AAA” 

BATTERY(1.5V) 

HW0705 1 

 

LAVA ROCK SET 

FP0002 

 

FOOTCAP FC0559 

 

1/4" X 15 MM BOLT

HW0034 

 

1/4" X 20 MM BOLT

HW0036 

 

1/4" X 40 MM BOLT

HW0086 

 

BOLT COVER 

HW0105 

18 

 

Ø6.5 X 1.0 MM 

WASHER 

HW0004 14 

 

Ø18XØ6.5 X1.5MM
          WASHER          

HW0103 4 

 

NUTS HW0717 

 

HEX BOLT DRIVER

HW0006 

 

HEX WRENCH 

HW0008 

Summary of Contents for ORL4PCCFPSW2-TAN

Page 1: ...mer Service Hotline at 1 800 416 3511 Between 9 00 AM and 5 00 PM Eastern Time Monday through Friday Or visit our website at www hanover products com To expedite any future warranty claims please reta...

Page 2: ...adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment...

Page 3: ...or placed on or near the appliance Any screen or guard removed for servicing an appliance must be replaced prior to operating the appliance Installation and repair should be done by a qualified servi...

Page 4: ...s appliance shall be used only outdoors in a well ventilated space and shall not be used in a building garage or any other enclosed space When this appliance is not is use the gas must be turned off a...

Page 5: ...IFICE ELBOW FP0310 1 G IGNITION MODULE FP0006 1 H PROPANE ORIFICE ZCF0021 1 I AAA BATTERY 1 5V HW0705 1 J LAVA ROCK SET FP0002 1 K FOOTCAP FC0559 4 L 1 4 X 15 MM BOLT HW0034 8 M 1 4 X 20 MM BOLT HW003...

Page 6: ...6 U FIREPIT TABLE TOP 1 V BACK PANEL 1 W LEFT SIDE PANEL 1 X RIGHT SIDE PANEL 1 Y DOOR PANEL 1 Z MIDDLE SUPPORT 1 AA LP SUPPORT 1 BB BOTTOM TOP CONNECTOR 1...

Page 7: ...holes in the side panels Hand tighten only Figure 2 3 Attach the middle support to the side panels by using four 1 4 x15 mm bolts and washers as shown in Figure 3 Guide the bolts through the holes in...

Page 8: ...top connector to the right side panel as shown in Figure 5 Do not over tighten Figure 5 6 With the help of another person carefully place the table top onto the table base After making any necessary...

Page 9: ...gure 9 pre fitted with gas hose which is connected to the table top into the hole of the door panel then use hex bolt driver to screw 1 4 x5mm nut the gas tank has fixed as shown in Figure 9a Connect...

Page 10: ...en all bolts Note each bolt must be tightened a few revolutions at a time Repeat until all bolts are tight Do not over tighten Over tightening may strip bolts Cover all bolts with covers 12 Pour the l...

Page 11: ...is found close the tank valve and tighten all connections NOTE NEVER USE A FLAME TO CHECK FOR LEAKS BATTERIES Make sure the control knob is in the OFF position Unscrew the push button cap on the ignit...

Page 12: ...b should pop back out and then remain lit Note If the fire does not light turn the knob to the OFF position and wait five 5 minutes before trying again 3 To turn down the flame push the control knob i...

Page 13: ...dule Check that the electrode is not cracked or broken Burner won t light Lack of oxygen Remove excess lava rocks or fire ices from around the ignition well Thermocouple not in flame Check that the ti...