8. White Balance, Luminance Adjustment
Approximately 30 minutes should be allowed for warm up before proceeding white balance adjustment.
First adjust PC mode and then adjust AV mo
onent 480i mode, component 480p mode. Before started adjust white balance, please set the Color Analyzer Ca210
to Channel 03 and set Ca210 to xyLv Mode.
Color Temp.
Cool
Normal
Warm
PC MODE
x
289
299
308
y
304
315
324
Y
350
350
350
AV MODE
x
289
299
308
y
304
315
324
Y
400
400
400
HDMI
x
289
299
308
y
304
315
324
Y
400
400
400
COMPONENT
(
480i/480p
)
x
289
299
308
y
304
315
324
Y
400
400
400
Note: The tolerance of the color coordinates should be less than ± 20.
Note: Step of AV, HDMI, COMPONENT480i, COMPONENT480p mode adjustment is the same as PC mode,
PC mode:
Ⅰ
. In the TV mode adjust volume to zero and press number key 9
8
7
6. It will achieve the
factory mode. Select the item of White Balance and press right key to enter it.
In the White Balance you can adjust 8 items.
1-3 items is RO, GO, BO
R, G, B Bias adjust.
4-6 items is RG, GG, BG
R, G, B Gain adjust.
7 item needn‟t adjust
8 items is color temperature select: Cool, Normal, and Warm.
Ⅱ
. Bias (Low luminance) adjustment:
1. Set the raster pattern (Black pattern with 1024×768) Input.
2. Adjust the brightness on OSD until Ca210 measurement reach the lowest value.
Ⅲ
. Gain adjustment:
A. Adjust Cold color-temperature:
1. Adjust Brightness to Ca210 Y>350 cd/m2
2. Switch the Ca210 to xyLv Mode (with press “MODE” button)
3. Switch the MEM. CH. to Channel 03 (with up or down arrow on Ca210)
4. Adjust the 4 item: GG, until Ca210 indicator reached the value Lv>350cd/m2
5. Adjust the 5 item: BG, until Ca210 indicator reached the value y = 0.304
6. Adjust the 6 item: RG, until Ca210 indicator reached the value x = 0.289
7. Repeat above procedure until Ca210 xy value meet the tolerance =±0.020
8. Enter the 8 item to select another color temperature to adjust.
B. Adjust Normal color-temperature:
1. Adjust Brightness to Ca210 Y>180 cd/m2
2. Switch the Ca210 to xyLv Mode (with press “MODE” button)
3. Switch the MEM. CH. to Channel 03 (with up or down arrow on Ca210)
4. Adjust the 4 item: GG, until Ca210 indicator reached the value Lv>350 cd/m2
5. Adjust the 5 item: BG, until Ca210 indicator reached the value y = 0.315
6. Adjust the 6 item: RG, until Ca210 indicator reached the value x = 0.299
Summary of Contents for AT06
Page 26: ...42 LCD TV Hannspree AT06 28 9 Remove the screws marked in red to remove 10 Panel...
Page 31: ...42 LCD TV Hannspree AT06 33 7 PCB Layout 7 1 Main Board...
Page 32: ...42 LCD TV Hannspree AT06 34...
Page 33: ...42 LCD TV Hannspree AT06 35 7 2 Power Board...
Page 34: ...42 LCD TV Hannspree AT06 36 7 3 IR Board...
Page 35: ...42 LCD TV Hannspree AT06 37 7 4 Tuner Board...
Page 36: ...42 LCD TV Hannspree AT06 38...
Page 37: ...42 LCD TV Hannspree AT06 39 7 5 Key Board 7 6 Side Board...
Page 48: ...42 LCD TV Hannspree AT06 50 10 2 Power Board...
Page 54: ...42 LCD TV Hannspree AT06 56...
Page 55: ...42 LCD TV Hannspree AT06 57 10 5 Side Board...