SPECIFICATIONS

FUNCTIONAL DESCRIPTION

1. Liquid Crystal Display
2.

CAL

 key, to enter and exit the calibration mode

3.

CFM

 key, to confirm calibration values

4.

↑↑↑↑↑

°C 

and 

↓↓↓↓↓

°C 

keys, to manually set temperature value for

compensation

5.

HOLD

 key, to freeze reading on display

6.

RANGE

 key, to select measurement range

7.

ON/OFF

 

key, to turn the meter on and off

+

-

Note:

These instruments use the following configuration.

It is recommended to use the Hanna 

HI 710005 

or 

HI 710006

voltage adapters (supplied with the meter) which are provided with
the proper polarity configuration.
The meters can also be powered with other adapters. In this case,
remember to check the correct polarity of the adapter before connect-
ing it to the meter.

REAR PANEL

1. BNC connector for pH or ORP (

pH 21

 only) electrode.

2. Temperature probe socket for use with the 

HI 7662

.

3. Power supply input. Plug the 12 Vdc adapter into the DC socket,

then into the mains.

Notes:

Make sure the mains line is protected by a fuse.

If the instrument needs to be unplugged, press the ON/OFF
key before disconnecting it from the mains.

Range

pH

0.00 to 14.00

ORP

±1999 mV (

pH 21

 only)

°C

0.0 to 100.0

Resolution

pH

0.01

 ORP

1 mV (

pH 21

 only)

°C

0.1

Accuracy

pH

±0.02

(@20°C/68°F)

  ORP

±2 mV (

pH 21

 only)

°C

±1

pH Calibration

Automatic, 1 or 2 point

Temperature

Automatic (with temperature probe) or

Compensation

manual (adjustable with arrow keys)

pH Electrode

HI 1110B

 combination pH electrode

with BNC and 1 m cable (

included

)

Temperature probe

HI 7662 

(

optional

)

Power supply

12 Vdc adapter (

included

)

Environment

0 to 50°C (32 to 122°F)

RH max 95% non-condensing

Dimensions

230 x 170 x 75 mm (9.1x6.7x 3")

Weight

500 g (1.1 lb.)

Summary of Contents for pH 21

Page 1: ...pH20 pH21 Basic pH meters Instruction Manual w w w h a n n a i n s t c o m...

Page 2: ...struction manual carefully before using the instru ment This manual will provide you with all the necessary information for the correct use of the instrument as well as a precise idea of its versatili...

Page 3: ...EAR PANEL 1 BNC connector for pH or ORP pH 21 only electrode 2 Temperature probe socket for use with the HI 7662 3 Power supply input Plug the 12 Vdc adapter into the DC socket then into the mains Not...

Page 4: ...nking The LCD will show the ORP mV value TAKING pH MEASUREMENTS Make sure that the instrument has been calibrated for pH before taking measurements see pH Calibration section for details Connect the s...

Page 5: ...H 10 01 buffer solution The meter automatically recognizes the buffer and displays the correct value After measurements turn the meter off by pressing the ON OFF key disconnect the power adapter from...

Page 6: ...roken insulation on the cable or cracks on the electrode stem or bulb If any scratches or cracks are present replace the electrode Rinse off any salt deposits with water Connectors must be perfectly c...

Page 7: ...ectrodes HI 8071 3 5M KCl AgCl electrolyte 4 x 30 mL for single junction electrodes FDA approved bottle HI 7072 1M KNO3 electrolyte 4 x 30 mL CLEANING PROCEDURE General Soak in HI7061 General Cleaning...

Page 8: ...s HI 8082 3 5M KCl electrolyte 4 x 30 mL for double junction electrodes FDA approved bottle ORP SOLUTIONS HI 7091M Reducing pretreatment solution 230 mL bottle HI 7091L Reducing pretreatment solution...

Page 9: ...2 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 01...

Reviews: