background image

3

2

PRELIMINARY EXAMINATION

Remove the instrument from the packing material and examine it to
make sure that no damage has occurred during shipping. If there is
any damage, notify your dealer or the nearest Hanna Customer
Service Center.

Each meter is supplied complete with:
• 3 x 1.5V AA alkaline batteries
• Instruction manual.

Note:

 Save all packing material until you are sure that the

instrument functions correctly. All defective items must be
returned in the original packing with the supplied accessories.

Dear Customer,
Thank you for choosing a Hanna product.
Please read this instruction manual carefully before using the instru-
ment.
If you need additional technical information, do not hesitate to e-mail
us at 

[email protected]

.

These instruments are in compliance with the 

 directives.

GENERAL DESCRIPTION

These instruments are powerful and flexible thermometers, which can
take measurements using different types of thermocouple probes (K, J
and T), and have been designed using the latest microprocessor
technology to provide reliable and accurate high resolution measure-
ments in a wide temperature reange.
Standard features include dual-level LCD (which allows continuous
displaying of High and Low temperature values), °C/°F selection,
HOLD function, auto-off capability, remaining battery life indication,
low battery detection, long battery life and two-year warranty.

HI 93542

HI 93552

 and 

HI 93552R

 are two-channel thermometers,

ideal for monitoring two samples at once.

HI 93551N

HI 93551R

HI 93552

 and 

HI 93552R

 offer additional

features, such as calibration of meter and probe at 0°C, backlit
display, and capability to store and recall a reading.
Moreover, the 

HI 93551R

 and 

HI 93552R

 models are equipped with

a serial port interface.

WARRANTY

All Hanna Instruments 

meters are warranted for two years

 against defects

in workmanship and materials when used for their intended purpose and main-
tained according to instructions. 

The

 

probes are warranted for a period of

six months

.

This warranty is limited to repair or replacement free of charge. Damages due to
accidents, misuse, tampering or lack of prescribed maintenance are not covered.
If service is required, contact the dealer from whom you purchased the instru-
ment. If under warranty, report the model number, date of purchase, serial
number and the nature of the failure. First obtain a Returned Goods Authoriza-
tion number from the Customer Service department, then return the instrument
with the Authorization number included along with shipment costs prepaid. If the
repair is not covered by the warranty, you will be notified of the charges. When
shipping any instrument, make sure it is properly packaged for complete protec-
tion.

TABLE OF CONTENTS

Preliminary Examination ............................................................... 3
General Description ....................................................................... 3
Specifications of HI 93551 and HI 93551N .................................. 4
Specifications of HI 93542 and HI 93552 .................................... 6
Specifications of HI 93551R and HI 93552R ................................ 8
Operational Guide ..................................................................... 10
Serial Port Communication ......................................................... 15
User Calibration ......................................................................... 16
Factory Recalibration .................................................................. 16
Battery Replacement .................................................................. 17
Accessories .................................................................................. 18

All rights are reserved. Reproduction in whole or in part is prohibited without the
written consent of the copyright owner, Hanna Instruments Inc.

Hanna Instruments reserves the right to modify the design, construction and

appearance of its products without advance notice.

Summary of Contents for HI 93551R

Page 1: ...Instruction Manual HI 93551 HI 93551N HI 93551R HI 93542 HI 93552 HI 93552R K J T Thermometers w w w h a n n a i n s t c o m...

Page 2: ...ch as calibration of meter and probe at 0 C backlit display and capability to store and recall a reading Moreover the HI 93551R and HI 93552R models are equipped with a serial port interface WARRANTY...

Page 3: ...to 0 1 F 0 3 F 328 0 to 270 1 F Accuracy 0 5 C 100 0 to 999 9 C 1 C outside 20 C 68 F 1 F 148 0 to 999 9 F 1 5 F outside for one year excluding probe error Typical EMC Deviation 3 C 6 F Battery 3x1 5V...

Page 4: ...t the thermocouple type ALT BL toggle the backlight ON and OFF SPECIFICATIONS Range K 200 0 to 999 9 C 1000 to 1371 C 328 0 to 999 9 F 1000 to 2500 F J 200 0 to 999 9 C 328 0 to 999 9 F 1000 to 1832 F...

Page 5: ...ght ON and OFF SPECIFICATIONS Range K 200 0 to 999 9 C 1000 to 1371 C 328 0 to 999 9 F 1000 to 2500 F J 200 0 to 999 9 C 328 0 to 999 9 F 1000 to 1832 F T 200 0 to 400 0 C 328 0 to 752 0 F Resolution...

Page 6: ...this feature set the internal slide switch located in the battery compart ment see figure on page 10 OPERATIONAL GUIDE To switch the instrument ON press the ON OFF key The thermometer will carry out a...

Page 7: ...ags light up to inform the user To select the desired channel use the T1 T2 key The 2 channel and HI 93551R models are also provided with the DISP function which allows the user to select the informat...

Page 8: ...HI 93551R and HI 93552R feature an RS232 output for transfer ring measurement data once every second for HI 93551R and once every 2 seconds for HI 93552R to devices provided with RS232 input PC or pr...

Page 9: ...your nearest Hanna Customer Service Center When the battery level is below 5 a warning symbol will blink on the LCD to indicate a low battery condition If the battery level is low enough to cause err...

Page 10: ...n long probe max 250 C 482 F HI 766TV1 Pipe clamp probe max 200 C 390 F with detachable handle mini connector to be used in conjunction with the HI 766HD probe handle HI 766PA Roller surface probe max...

Page 11: ...942 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax...

Reviews: