background image

33

32

When the batteries are run
down "LO BAT" is displayed on
the Liquid Crystal Display to
warn the user.
Battery replacement must only
take place in a non-hazardous
area using alkaline AA type
1.5V batteries.
In order to replace run down
batteries, remove the two screws
on the rear cover of the instru-
ment and replace the four 1.5V
AA batteries with new alkaline
ones, paying attention to the
correct polarity.
A 12VDC power source can also
be used to power the unit (Ac-
cessories on page 36).

Note:

The instrument uses the following configuration.

It is recommended to use the Hanna 

HI 710005

     and 

HI 710006

voltage adapters that use the proper polarity configuration.

HI 9161

HI 9261

 and 

HI 91610

     can also be used with other

adapters supplying a 12VDC output. In this case, remember to check
the correct polarity of your adapter before connecting it to the meter.

BATTERY REPLACEMENT

BATTERY REPLACEMENT

BATTERY REPLACEMENT

BATTERY REPLACEMENT

BATTERY REPLACEMENT

LO BAT

-

-

+

+

1.5V

1.5V

-

-

+

+

1.5V

1.5V

SCREW

POTS

RESET

+

-

Allow about 5 cm (2") of paper to exit from the printer and then
replace the cover.

TO RESET THE PRINTER

Take the battery cover off by
removing the screws on the back
of the meter. Using a blunt
pencil press the black reset but-
ton. This will reset the printing
mechanism.
Before replacing the battery
cover, investigate likely cause of
the printer jam (e.g. the pa-
per might be caught under
the cover preventing the paper
from advancing).
Replace the battery cover and
tighten the screws.

-

-

+

+

1.5V

1.5V

-

-

+

+

1.5V

1.5V

SCREW

POTS

RESET

Summary of Contents for HI 9161

Page 1: ...e in Compliance with the CE Directives HI 9161C ON OFF PAPER RANGE RH 5 0 95 0 C 20 0 60 0 INTV instrum nts e UP PRINT DOWN RANGE LOG MICROPROCESSOR PRINTING THERMOHYGROMETER HI 9161 HI 9261 HI 91610...

Page 2: ...by the probe into a digital readout in Relative Humidity The standard cable is 2 meters 7 long and a 5 meter 16 5 version is also available Note the RH probe sensor must never come into contact with w...

Page 3: ...7 5 4 HI 9161C 1 For special applications HI 70606 2 or HI 70606 5 RH probes can also be used These probes come with a sintered cap on the sensor shaft for protection in dusty or corrosive environment...

Page 4: ...0C 1 FUNCTIONAL DESCRIPTION HI 91610 FUNCTIONAL DESCRIPTION HI 91610 FUNCTIONAL DESCRIPTION HI 91610 FUNCTIONAL DESCRIPTION HI 91610 FUNCTIONAL DESCRIPTION HI 91610 FUNCTIONAL DESCRIPTION HI 9261 FUNC...

Page 5: ...power impact type belt 14 characters per line using 38 mm plain paper HI 710034 Printing Intervals Selectable from 1 2 5 10 15 30 60 120 180 min Operating Conditions 0 to 50 C 32 to 122 F max RH 98 no...

Page 6: ...ither the RH or temperature read ing on the display press RANGE The reading will appear without decimal digit when shown on the lower secondary display The tempera ture range on the secondary display...

Page 7: ...r sensors which provide greater accuracy and faster response than conventional thermistor probes Hanna temperature probes are supplied pre calibrated from the factory and are ready to use Available in...

Page 8: ...P or the DOWN keys 24 hour clock To memorize the hour press RANGE once again The minutes will start blinking Likewise use UP and DOWN to set the minutes Press the INTV and the RANGE keys simultaneousl...

Page 9: ...INTV TIME UP DATE DOWN TIME INTV TIME DATE UP To select the hour press the UP or DOWN keys 24 hour clock To set the hour press the TIME key again and the minutes will blink Use the UP or DOWN keys to...

Page 10: ...5 1 1 5 1 6 5 2 R H 2 5 0 C PRINT To view RH on the primary display press RANGE To view temperature on the primary display when in RH mode press RANGE again If is displayed it indicates that no probe...

Page 11: ...OFF key The instrument will then make one final exit printout The running log number can be reset by simply removing the batteries 1 0 0 1 9 6 0 1 0 0 0 5 M 0 0 0 6 1 2 0 1 6 5 1 R H 2 5 0 C ON OFF PR...

Page 12: ...he LOG key The log number and remaining page numbers will appear on display LOG Press the ALT and LOG key simultaneously to enter the logging mode The current log number and the remaining page numbers...

Page 13: ...ns out the meter will not advise the operator and the printouts could be lost If this hap pens stop the printer by pressing ALT and PAPER key simultaneously Data will be kept in memory Insert a new pa...

Page 14: ...ON KIT Li Cl 11 1 Na Cl 75 4 CALIBRATION KIT H 2 O 12cc N a C l Li Cl 11 1 Na Cl 75 4 CALIBRATION KIT 12 3 6 9 4 h CALIBRATION KIT Li Cl 11 1 Na Cl 75 4 12 3 6 9 4 h All Hanna thermohygrometers have b...

Page 15: ...storage or elabora tion without having to connect and disconnect cables between the meter and your PC Data can be further elaborated with the new optional HI 92000 Windows compatible application soft...

Page 16: ...med reset the printer see page 32 SELF DIAGNOSTIC FUNCTIONS SELF DIAGNOSTIC FUNCTIONS SELF DIAGNOSTIC FUNCTIONS SELF DIAGNOSTIC FUNCTIONS SELF DIAGNOSTIC FUNCTIONS Capacity 8000 data samples which are...

Page 17: ...tion HI 9161 HI 9261 and HI 91610 can also be used with other adapters supplying a 12VDC output In this case remember to check the correct polarity of your adapter before connecting it to the meter BA...

Page 18: ...EMPERATURE PROBES These probes use highly sensitive thermistor sensors which provide greater accuracy faster response and a temperature range that is superior to conventional probes All Hanna temperat...

Page 19: ...te of purchase All rights are reserved Reproduction in whole or in part is prohibited without the written consent of the copyright owner Hanna Instruments Inc 584 Park East Drive Woonsocket Rhode Isla...

Page 20: ...ons IEC 801 2 Electrostatic Discharge IEC 801 3 RF Radiated IEC 801 4 Fast Transient EN 55022 Radiated Class B Date of Issue 01 02 1996 D Volpato Engineering Manager On behalf of Hanna Instruments S r...

Page 21: ...A LITERATURE HANNA LITERATURE LAB RECORDING WATER ANALYSIS ENVIROCARE GENERAL CATALOG These and many others catalogs handbooks and leaflets are avail able from Hanna To receive your free copy contact...

Reviews: