background image

2

3

Dear Customer,
Thank you for choosing a Hanna product. Please read this instruction
manual carefully before using the meter. This manual will provide you
with the necessary information for a correct use of the instrument.
If you need additional technical information, do not hesitate to e-mail
us at 

[email protected]

.

These instruments are in compliance with the 

 directives.

TABLE OF CONTENTS

PRELIMINARY EXAMINATION ........................................................ 3
GENERAL DESCRIPTION ................................................................ 3
FUNCTIONAL DESCRIPTION HI8014 .............................................. 4
SPECIFICATIONS HI8014 ............................................................. 5
FUNCTIONAL DESCRIPTION HI8915 .............................................. 6
SPECIFICATIONS HI8915 ............................................................. 7
FUNCTIONAL DESCRIPTION HI931000 .......................................... 8
SPECIFICATIONS HI931000 .......................................................... 9
OPERATIONAL GUIDE ................................................................. 10
pH CALIBRATION ....................................................................... 14
pH VALUES AT VARIOUS TEMPERATURES ................................... 18
TAKING REDOX MEASUREMENTS ................................................. 18
TEMPERATURE CALIBRATION ...................................................... 19
mV OUTPUT .............................................................................. 19
DISPLAY CODES GUIDE ............................................................... 19
ELECTRODE CONDITIONING AND MAINTENANCE ........................... 20
BATTERY REPLACEMENT .............................................................. 23
ACCESSORIES ............................................................................. 24
CE DECLARATION OF CONFORMITY .............................................. 27

WARRANTY

All Hanna Instruments

 meters are warranted for two years 

against defects in

workmanship and materials when used for their intended purpose and maintained
according to instructions. 

Electrodes and probes are warranted for six months.

This warranty is limited to repair or replacement free of charge. Damages due to
accident, misuse, tampering or lack of prescribed maintenance are not covered. If
service is required, contact the dealer from whom you purchased the instrument. If
under warranty, report the model number, date of purchase, serial number and the
nature of the failure. If the repair is not covered by the warranty, you will be notified of
the charges incurred. If the instrument is to be returned to Hanna Instruments, first
obtain a Returned Goods Authorization number from the Customer Service department
and then send it with shipping costs prepaid. When shipping any instrument, make
sure it is properly packaged for complete protection.

PRELIMINARY EXAMINATION

Remove the instrument from the packing material and examine it
carefully to make sure that no damage has occurred during ship-
ment. If noticeable damage is found, notify your Dealer or the nearest
Hanna Customer Service Center.

Note:

 Save all packing material until you are sure that the

instrument functions correctly. Any defective item must be
returned in the original packing together with the supplied
accessories.

GENERAL DESCRIPTION

HI 8014, HI 8915

 and 

HI 931000 

are hand-held pH/mV meters

with interchangeable plastic-body electrodes, simple controls on the
front panel, low battery detector, large easy-to-read display, simple
calibration procedure and lightweight ABS plastic housing.

HI 8014

 is an affordable portable 

pH/mV meter

. The pH or mV

ranges are easily selected with a rotary knob, as well as the °C
range for manual temperature compensation. 

HI 8014

 comes

supplied with: 

HI 1230B

 combination, double-junction,  gel pH

electrode, one 9V battery and calibration screwdriver.

HI 8915

 is a portable 

pH/mV/°C meter

 that combines accurate

pH measurements with a recorder output capability and auto-
matic temperature compensation. Two recorder output terminals
make it possible to attach a plotter or recorder directly to the
meter for a hard copy of the measurements. Pressing the HOLD
key will freeze the reading on the display. Calibration is per-
formed using the two trimmers on the front panel. 

HI 8915

comes supplied with: 

HI 1230B 

combination, double-junction,

gel pH electrode, 

HI 7669AW

 temperature probe, one 9V bat-

tery and calibration screwdriver.

HI 931000

 is a compact, microprocessor-based 

pH/°C

 

meter

,

which comes supplied with: 

HI 1217D 

combination gel pH/°C

electrode with built-in temperature sensor and signal amplifier,
one 9V battery and 

HI 710004

 soft carrying case.

Summary of Contents for HI 8915

Page 1: ...1 Instruction Manual HI 8014 HI 8915 HI 931000 Portable pH Meters w w w h a n n a i n s t c o m...

Page 2: ...end it with shipping costs prepaid When shipping any instrument make sureitisproperlypackagedforcompleteprotection PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine i...

Page 3: ...temperature manually mV pH For SLOPE calibration of pH AP For OFFSET calibration of pH SPECIFICATIONS HI8014 HI 8014 Range pH 0 00 to 14 00 mV 1999 Resolution pH 0 01 mV 1 Accuracy pH 0 01 20 C 68 F m...

Page 4: ...ected the LCD will show 25 C 11 SLOPE trimmer for SLOPE calibration of pH 12 recorder output mV output negative connection SPECIFICATIONS HI8915 HI 8915 Range pH 0 00 to 14 00 mV 1999 C 0 0 to 100 0 R...

Page 5: ...H 0 00 to 14 00 C 0 0 to 70 0 Resolution pH 0 01 C 0 1 Accuracy pH 0 01 20 C 68 F C 0 5 Typical EMC pH 0 30 Deviation C 1 pH Calibration Automatic 2 point with 3 memorized standard buffers pH 7 01 4 0...

Page 6: ...n the meter on by pressing ON OFF ON OFF TOP VIEW BNC electrode connector OFF mV C pH TOPVIEWOFHI8915 ins rum ns CFM C CAL OFF ON pH HI 931000 ON OFF pH MEASUREMENTS For HI 8014 To take a pH measureme...

Page 7: ...014 HI 8915 Connect an ORP electrode to the BNC socket on the top of the meter To enter the mV mode ORP Oxidation Reduction Potential turn the instrument ON and select the mV mode To measure the mV of...

Page 8: ...the temperature of the buffer solu tion with a ChecktempC or another accurate thermometer e g 20 C Note The electrode should be submerged approximately 4 cm 1 into the solution The ChecktempC should...

Page 9: ...Note The indicator blinks when the reading is not stable Press CAL and the display will flash 7 01 Remove the electrode protective cap rinse the electrode tip with some pH 7 01 solution then immerse t...

Page 10: ...n use the tip of the electrode should be kept moist and safe from any mechanical stress which might cause damage to the glass platinum junction TEMPERATURE CALIBRATION HI 8915 and HI 931000 have been...

Page 11: ...ectrode and the cable The cable used for the connection to the meter must be intact and there must be no points of broken insulation on the cable or cracks on the electrode stem or bulb Connectors mus...

Page 12: ...Response Excessive Drift Soak the tip in Hanna Solu tion HI7061 for 30 minutes rinse thoroughly in distilled water and then follow the Cleaning Procedure above For ORP Electrodes polish the metal tip...

Page 13: ...50 mL HI 7082 3 5M KCl electrolyte 4 x 50 mL for double junction electrodes ORP SOLUTIONS HI 7020M Test solution 200 275 mV 230 mL bottle HI 7020L Test solution 200 275 mV 500 mL bottle HI 7091M Redu...

Page 14: ...and HI8915 HI 710031 General purpose rugged carrying case HI 721311 Rugged carrying case for HI 8014 and HI 8915 with pH 4 01 and pH 7 01 solutions and screwdriver HI 731326 Calibration screwdriver 2...

Page 15: ...42 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 0...

Reviews: