ACCESSORIES

pH CALIBRATION SOLUTIONS

HI 70004P

pH 4.01 buffer solution, 20 mL sachet, 25 pcs

HI 7004M

pH 4.01 buffer solution, 230 mL bottle

HI 7004L

pH 4.01 buffer solution, 500 mL bottle

HI 7006M

pH 6.86 buffer solution, 230 mL bottle

HI 7006L

pH 6.86 buffer solution, 500 mL bottle

HI 70007P

pH 7.01 buffer solution, 20 mL sachet, 25 pcs

HI 7007M

pH 7.01 buffer solution, 230 mL bottle

HI 7007L

pH 7.01 buffer solution, 500 mL bottle

HI 7009M

pH 9.18 buffer solution, 230 mL bottle

HI 7009L

pH 9.18 buffer solution, 500 mL bottle

HI 70010P

pH 10.01 buffer solution, 20 mL sachet, 25 pcs

HI 7010M

pH 10.01 buffer solution, 230 mL bottle

HI 7010L

pH 10.01 buffer solution, 500 mL bottle

ELECTRODE STORAGE SOLUTIONS

HI 70300M

Storage solution, 230 mL bottle

HI 70300L

Storage solution, 500 mL bottle

ELECTRODE CLEANING SOLUTIONS

HI 70000P

Electrode rinsing solution, 20 mL sachet, 25 pcs

HI 7061M

General cleaning solution, 230 mL bottle

HI 7061L

General cleaning solution, 500 mL bottle

HI 7073M

Protein cleaning solution, 230 mL bottle

HI 7073L

Protein cleaning solution, 500 mL bottle

HI 7074M

Inorganic cleaning solution, 230 mL bottle

HI 7074L

Inorganic cleaning solution, 500 mL bottle

HI 7077M

Oil & Fat cleaning solution, 230 mL bottle

HI 7077L

Oil & Fat cleaning solution, 500 mL bottle

REFILLING ELECTROLYTE SOLUTIONS

HI 7071

3.5M KCl + AgCl electrolyte, 4 x 50 mL, for single
junction electrodes

HI 7072

1M KNO

3

 electrolyte, 4 x 50 mL

HI 7082

3.5M KCl electrolyte, 4 x 50 mL, for double junction
electrodes

ORP SOLUTIONS

HI 7020M

Test solution, 200-275 mV, 230 mL bottle

HI 7020L

Test solution, 200-275 mV, 500 mL bottle

HI 7091M

Reducing pretreatment solution, 230 mL bottle

HI 7091L

Reducing pretreatment solution, 500 mL bottle

HI 7092M

Oxidizing pretreatment solution, 230 mL bottle

HI 7092L

Oxidizing pretreatment solution, 500 mL bottle

pH ELECTRODES

HI1043B / HI1040S

Glass body, double junction, refillable,

combination 

pH

 electrode. Use: strong acid/alkali.

HI1053B / HI1050S

Glass body, triple ceramic, conic shape,

refillable, combination 

pH

 electrode. Use: emulsions.

HI1083B

Glass body, micro, Viscolene, non-refillable, combi-

nation 

pH

 electrode. Use: biotechnology, micro titration.

HI1131B / HI1111S

Glass body, single junction, refillable,

combination 

pH

 electrode. Use: general purpose.

HI1330B / HI1310S

Glass body, semimicro, single junction,

refillable, combination 

pH 

electrode. Use: laboratory.

HI1331B / HI1311S

Glass body, semimicro, single junction,

refillable, combination 

pH 

electrode. Use: flasks.

HI1230B / HI1210S

Plastic body, double junction, gel-filled,

combination 

pH 

electrode. Use: general purpose.

HI2031B / HI2020S

Glass body, semimicro, conic, refillable,

combination 

pH

 electrode. Use: semisolid products.

HI1332B / HI1312S

Plastic body, double junction, refillable,

combination 

pH 

electrode. Use: general purpose.

FC100B

PVDF body, double junction, refillable, combina-

tion 

pH 

electrode. Use: food industry, general.

FC200B

 

/ FC200S

PVDF body, single junction, conic,

Viscolene, non-refillable, combination 

pH 

electrode. Use:

meat & cheese.

B = BNC  CONNECTION PLUG + 1 m (3.3’) CABLE

S = SCREW-TYPE CONNECTOR

Summary of Contents for HI 8915

Page 1: ...1 Instruction Manual HI 8014 HI 8915 HI 931000 Portable pH Meters w w w h a n n a i n s t c o m...

Page 2: ...end it with shipping costs prepaid When shipping any instrument make sureitisproperlypackagedforcompleteprotection PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine i...

Page 3: ...temperature manually mV pH For SLOPE calibration of pH AP For OFFSET calibration of pH SPECIFICATIONS HI8014 HI 8014 Range pH 0 00 to 14 00 mV 1999 Resolution pH 0 01 mV 1 Accuracy pH 0 01 20 C 68 F m...

Page 4: ...ected the LCD will show 25 C 11 SLOPE trimmer for SLOPE calibration of pH 12 recorder output mV output negative connection SPECIFICATIONS HI8915 HI 8915 Range pH 0 00 to 14 00 mV 1999 C 0 0 to 100 0 R...

Page 5: ...H 0 00 to 14 00 C 0 0 to 70 0 Resolution pH 0 01 C 0 1 Accuracy pH 0 01 20 C 68 F C 0 5 Typical EMC pH 0 30 Deviation C 1 pH Calibration Automatic 2 point with 3 memorized standard buffers pH 7 01 4 0...

Page 6: ...n the meter on by pressing ON OFF ON OFF TOP VIEW BNC electrode connector OFF mV C pH TOPVIEWOFHI8915 ins rum ns CFM C CAL OFF ON pH HI 931000 ON OFF pH MEASUREMENTS For HI 8014 To take a pH measureme...

Page 7: ...014 HI 8915 Connect an ORP electrode to the BNC socket on the top of the meter To enter the mV mode ORP Oxidation Reduction Potential turn the instrument ON and select the mV mode To measure the mV of...

Page 8: ...the temperature of the buffer solu tion with a ChecktempC or another accurate thermometer e g 20 C Note The electrode should be submerged approximately 4 cm 1 into the solution The ChecktempC should...

Page 9: ...Note The indicator blinks when the reading is not stable Press CAL and the display will flash 7 01 Remove the electrode protective cap rinse the electrode tip with some pH 7 01 solution then immerse t...

Page 10: ...n use the tip of the electrode should be kept moist and safe from any mechanical stress which might cause damage to the glass platinum junction TEMPERATURE CALIBRATION HI 8915 and HI 931000 have been...

Page 11: ...ectrode and the cable The cable used for the connection to the meter must be intact and there must be no points of broken insulation on the cable or cracks on the electrode stem or bulb Connectors mus...

Page 12: ...Response Excessive Drift Soak the tip in Hanna Solu tion HI7061 for 30 minutes rinse thoroughly in distilled water and then follow the Cleaning Procedure above For ORP Electrodes polish the metal tip...

Page 13: ...50 mL HI 7082 3 5M KCl electrolyte 4 x 50 mL for double junction electrodes ORP SOLUTIONS HI 7020M Test solution 200 275 mV 230 mL bottle HI 7020L Test solution 200 275 mV 500 mL bottle HI 7091M Redu...

Page 14: ...and HI8915 HI 710031 General purpose rugged carrying case HI 721311 Rugged carrying case for HI 8014 and HI 8915 with pH 4 01 and pH 7 01 solutions and screwdriver HI 731326 Calibration screwdriver 2...

Page 15: ...42 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 0...

Reviews: