background image

9

8

TEMPERATURE PROBES & ACCESSORIES

HANNA instruments

®

 offers a wide range of temperature probes for measure-

ments in air, surface, liquid and for penetration applications.
These probes use highly sensitive thermistor sensors to provide greater accuracy,
faster response and a temperature range that is superior to conventional
thermistor probes.

HI 765

 series of temperature probes are supplied pre-calibrated at the factory

and ready to use, making it possible to switch from one to another without
needing time-consuming and tedious calibration procedures.

Different handle colors are available to avoid cross contamination during testing.

HI 765A

Air/gas probe with 1 m (3.3') cable and white handle

HI 765A/10

Air/gas probe with 10 m (33') cable and white handle

HI 765BL

General purpose/liquid probe, 1 m (3.3') cable & black

 

handle

HI 765BL/10

General purpose/liquid probe, 10 m (33') cable & black handle

HI 765L

General purpose/liquid probe, 1 m (3.3') cable & white handle

HI 765L/10

General purpose/liquid probe, 10 m (33') cable & white handle

HI 765PBL

Penetration probe with 1 m (3.3') cable and blue handle

HI 765PBL/10

Penetration probe with 10 m (33') cable and blue handle

HI 765PG

Penetration probe with 1 m (3.3') cable and green handle

HI 765PG/10

Penetration probe with 10 m (33') cable and green handle

HI 765PR

Penetration probe with 1 m (3.3') cable and red handle

HI 765PR/10

Penetration probe with 10 m (33') cable and red handle

HI 765PW

Penetration probe with 1 m (3.3') cable and white handle

HI 765PW/10

Penetration probe with 10 m (33') cable and white handle

HI 765W

Wire probe without handle for hard-to-reach places, 1 m (3.3')
cable

HI 765W/10

Wire probe without handle for hard-to-reach places, 10 m (33')
cable

BATTERY REPLACEMENT

These instruments are powered by a 9V battery.

When the battery level is too low to ensure reliable readings, the Battery Error
Prevention System (BEPS) automatically shuts down the LCD.

For a correct functioning of the instrument, replace the battery.

To access the battery, remove the battery cover
on the rear of the meter by applying pressure
in the indicated direction.

Replace the battery with a new one and
reattach the cover.

Battery replacement must only take place in a
safe area and using a 9V alkaline battery.

BATTERY

OTHER ACCESSORIES

HI 710002

Soft carrying case

HI 710009

Shockproof rubber boot, blue

HI 710010

Shockproof rubber boot, orange

HI 721316

Rugged carrying case

Summary of Contents for HI 8752

Page 1: ...Instruction Manual HI 8751 HI 8752 HI 8753 Electronic Thermometers for Education w w w h a n n a i n s t c o m ...

Page 2: ...nt functions correctly Any defective item must be returned in the original packing with the supplied accessories TABLE OF CONTENTS PRELIMINARY EXAMINATION 3 GENERAL DESCRIPTION 3 FUNCTIONAL DESCRIPTION SPECIFICATIONS OF HI 8751 4 FUNCTIONAL DESCRIPTION SPECIFICATIONS OF HI 8752 5 FUNCTIONAL DESCRIPTION SPECIFICATIONS OF HI 8753 6 OPERATIONAL GUIDE 7 CALIBRATION 7 BATTERY REPLACEMENT 8 TEMPERATURE ...

Page 3: ...PW probe Probe HI 765PW stainless steel 1 m 3 3 cable included Battery Type Life 1 x 9V IEC 6LR61 approx 300 hours of continuous use Environment 0 to 50 C 32 to 122 F RH max 95 non condensing Dimensions 180 x 83 x 40 mm 7 1x3 3x1 6 Weight 265 g 9 3 oz Range 58 to 338 F Resolution 1 F Accuracy 0 5 F S for one year excluding probe error Typical EMC Deviation 2 F with HI 765BL probe Probe HI 765BL st...

Page 4: ... KEYS to be connected to the probe socket on the thermometer If the reading differs more than 0 4 C 0 8 F from the test key value the unit is due for recalibration Choose the test key that better fits your application needs HI 765 18C Calibration test key at 18 0 C HI 765000C Calibration test key at 0 0 C HI 765070C Calibration test key at 70 0 C HI 765 004F Calibration test key at 0 4 F HI 765032...

Page 5: ...BL 10 Penetration probe with 10 m 33 cable and blue handle HI 765PG Penetration probe with 1 m 3 3 cable and green handle HI 765PG 10 Penetration probe with 10 m 33 cable and green handle HI 765PR Penetration probe with 1 m 3 3 cable and red handle HI 765PR 10 Penetration probe with 10 m 33 cable and red handle HI 765PW Penetration probe with 1 m 3 3 cable and white handle HI 765PW 10 Penetration ...

Page 6: ...struments in residential areas could cause unacceptable interference to radio and TV equipment Any variation introduced by the user to the supplied equipment may degrade the instruments EMC performance To avoid electrical shock do not use these instruments when voltage at the measurement surface exceeds 24 Vac or 60 Vdc To avoid damages or burns do not perform any measurement in microwave ovens ...

Page 7: ...58 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 011 615 8582 Taiwan Tel 886 2 2739 3014 Fax 886 2 2739 2983 Thailand Tel 662 619 0708 11 Fax 662 619 0061 UnitedKingdom Tel 01525 850 855 Fax 01525 853 668 USA Tel 401 765 7500 Fax 401 765 7575 For e mail contacts and c...

Reviews: