Hanna Instruments HI 83746 Instruction Manual Download Page 4

4

The 

HI 83746 

is an auto-diagnostic portable microprocessor meter that benefits from Hanna’s

years of experience as a manufacturer of analytical instruments. It has an advanced optical system
based on a special tungsten lamp and a narrow band interference filter that allows most accurate
and repeatable readings. All instruments are factory calibrated.
The auto-diagnostic feature of this meter ensures always optimal measurement conditions to
ensure most precise readings. The light level is automatically adjusted each time a zero-measurement
is made, and the temperature of the lamp is controlled to avoid overheating.

GENERAL DESCRIPTION

The determination of concentration of reducing sugars (RS) is one of the most important parameters
that need to be measured during the wine making process.
Following the increase of RS during maturation of grapes can help to decide when to start harvest.
Having the highest possible sugar content is important because this is the main parameter that
defines the commercial value of grapes.
During the alcoholic fermentation instead, the decrease of sugars can be followed to decide when
fermentation is completed, or allows making corrective actions if the content of RS is too low to
obtain the desired alcohol degree or sweetness.

The predominant RS in grape products are glucose and fructose (hexoses). After reaction with excess
alkaline cupric tartrate (Fehling reagents), the RS content can be determined colorimetricly. The
Fehling method is not an exact determination but an index of the reducing sugar concentration,
because the reaction depends upon the amount and kind of RS present. When the reducing sugar
content is known at the beginning of fermentation, the potential alcohol degree can be estimated
multiplying the sugar concentration (in g/L) by 0.06.

Phenols interfere in the Fehling reaction and therefore red wine must be decolorized prior to analysis.
Wine also contains non-fermentable reducing sugars like pentose which will also be analysed by this
method.

Typical content of reducing sugars in must and wine

Must

Must

Must

Must

Must

sweet must

20-25 %

200-250 g/L

normal

10-20 %

100-200 g/L

in fermentation

4-12.5 %

40-125 g/L

Wine

Wine

Wine

Wine

Wine

Sweet

2.5-12.5 %

25-125 g/L

Semi sweet

0.8-2.5 %

8-25 g/L

Almost dry

0.2-0.8 %

2-8 g/L

Dry

0-0.2 %

0-2 g/L

SIGNIFICANCE OF USE

17

Battery replacement must only take place in a non-

hazardous area.
The blinking “ ” will appear when the batteries
power gets low.
When batteries are completely discharged, “0% bAtt”
will appear and after two seconds the instrument is
switched off.
Remove the battery cover from the bottom of the
instrument and change the old batteries with 4 fresh
1.5V batteries, paying attention to the correct polarity.
Replace the cover.

BATTERIES REPLACEMENT

REAGENT SETS
HI 83746-20

Reducing Sugars reagents set (ca. 20 tests)

HI 93703-59

Charcoal for decoloration of Red Wine (about 100 tests)

OTHER ACCESSORIES
HI 839800

Reactor

HI 740216

Test tube cooling rack (for 25 vials)

HI 740217

Laboratory bench safety shield

HI 731331

Glass cuvets (4 pcs)

HI 731340

200 

µ

L automatic pipette

HI 731350

Plastic tips for 200 

µ

L automatic pipette (25 pcs)

HI 731341

1000 

µ

L automatic pipette

HI 731351

Plastic tips for 1000 

µ

L automatic pipette (25 pcs)

HI 740232

Filter paper type I (100 pcs)

HI 731325W

Caps for cuvets (4 pcs)

HI 93703-50

Cuvets cleaning solution (230 mL)

HI 740027P

1.5V AA batteries (10 pcs)

HI 710005

Voltage adapter from 115V to 12 VDC (USA plug)

HI 710006

Voltage adapter from 230V to 12 VDC (European plug)

ACCESSORIES

Summary of Contents for HI 83746

Page 1: ...Instruction Manual HI 83746 REDUCING SUGARS ISM for wine analysis w w w h a n n a i n s t c o m This Instrument is in Compliance with the CE Directives 20 MAN83746R2 03 06 w w w h a n n a i n s t c o...

Page 2: ...necessary information for the correct use of the instrument Please read it carefully before using the meter If you need additional technical information do not hesitate to e mail us at tech hannainst...

Page 3: ...ariation introduced by the user to the supplied equipment may degrade the instruments EMC performance To avoid damages or burns do not put the instrument in microwave ovens For yours and the instrumen...

Page 4: ...ontent is known at the beginning of fermentation the potential alcohol degree can be estimated multiplying the sugar concentration in g L by 0 06 Phenols interfere in the Fehling reaction and therefor...

Page 5: ...presentativelotofreagent an operator obtained with a single instrument a standard deviation of 0 50 g L PRECISION AND ACCURACY 16 IftheexpectedRSconcentrationislessthan5 00g Lpleaserefertotheinstructi...

Page 6: ...ted as well as a proper central wavelength to optimize measurements The optical system of Hanna s HI 83000 series colorimeters is based on special subminiature tungsten lamps and narrow band interfere...

Page 7: ...absorption of light It is recommended not to touch the cuvet walls with hands Furthermore in order to maintain the same conditions during the zeroing and the measuring phases it is necessary to close...

Page 8: ...ftheexpectedRSconcentrationisabove50 00g L forexampleformustanalysis itisrecommended todilutethesample4or5timeswithwater ii IftheexpectedRSconcentrationisbelow5 00g Lpleaserefertoinstructionsonpage16...

Page 9: ...t the meter is making a measurement Batteries voltage is getting low and the batteries need to be replaced Indicates that the meter is performing a zero measurement The light intensity is automaticall...

Page 10: ...t 11 The instructions listed below should be carefully followed during testing to ensure best accuracy For dosing the wine sample and the reagent we recommend to use the supplied Hanna automatic pipet...

Reviews: