background image

27

26

Adipic Acid
Alcohol Amyl
Alcohol, Diacetone
Alcohol, Isopropyl
Alcohol, Methyl
Aluminium, Ammonium Sul-
fate
Aluminium Chloride
Aluminium Sulfate
Alums
Ammonium Carbonate
Ammonium Chloride
Ammonium Fluoride
Ammonium Hydroxide
Ammonium Nitrate
Ammonium Phosphate
Ammonium Sulfate
Aqua Ammonia
Arsenic Acid
Barium Carbonate
Barium Chloride
Barium Hydroxide
Barium Sulfate
Beer
Beet Sugar Liquors
Bismuth Carbonate
Back Liquor
Bleach
Borax
Boric Acid
Bromic Acid
Butyric Acid
Calcium Bisulfite
Calcium Carbonate
Calcium Chlorate
Calcium Chloride
Calcium Hydroxide
Calcium
Hypochlorite
Calcium Nitrate
Calcium Sulfate
Carbonic Acid

Castor Oil
Caustic Soda
Chloral Hydrate
Chromic Acid 50%
Citric Acid
Copper Chloride
Copper Cyanide
Copper Nitrate
Copper Sulfate
Corn Oil
Cottonseed Oil
Cresylic Acid
Crude Oil
Dextrose
Detergents (general)
Diesel Fuel
Dictyl Phthalate
Disodium Phosphate
Ethanol (1-95%)
Ethylene Dichloride
Ethylene Glycol
Fatty Acids
Ferric Chloride
Ferric Nitrate
Ferric Sulfate
Ferrous Chloride
Ferrous Sulfate
Fluoboric Acid
Fluosilicic Acid
Formaldehyde
Fruit Juice Pulp
Fuel Oil
Gallic Acid
Gasoline, Refined
Glucose
Glycerine or Glycerol
Glycolic Acid 30%
Hexane
Hydrazine
Hydrobromic Acid 20%
Hydrochloric Acid (Con-
centrated)

Partial Listing of Chemicals that can be
used with BlackStone Pumps

(Rated for 45°C. For higher temperatures
consult your dealer or nearest Hanna Ser-
vice Center)

CHEMICAL COMPATIBILITY GUIDE

Cleaning the Pumphead

The pumphead should be cleaned at regular
intervals and at least once a year. Remove
the deposits that form in the cavities with a
solution that is neutral to the chemical the
pump has been dosing.  Inspect the head
for any cracks or worn areas.

Replace if necessary with parts from the
pumphead spare part HI 721106 (for BL7,
BL10, BL15 and BL20) or HI 721107 (for
BL1.5, BL3 and BL5).

SCHEDULED MAINTENANCE

After 50 hours

Tight the pumphead screws with a torque
force of 2.5 Nm (22" lbf).

After 12 months

It is recommended to replace HI 721102, HI
721103
 (suction and discharge valves as-
semblies) as well as the O-rings.  The LDPE
hose can also deteriorate over time and, for
safety reasons, should also be changed
with  HI 720032.

After 24 months

It is recommended to replace HI 721102, HI
721103, HI 720032
 and HI 721106 (for BL7,
BL10, BL15 and BL20) or HI 721107 (for
BL1.5, BL3 and BL5).

Summary of Contents for BL Series Pumps

Page 1: ...Instruction Manual BL1 5 BL3 BL5 BL7 BL10 BL15 BL20 Dosing Pumps w w w h a n n a i n s t c o m...

Page 2: ...itch Dear Customer Thank you for choosing a Hanna product Please read this instruction manual carefully before using the pump If you need additional technical information do not hesitate to e mail us...

Page 3: ...mp Always wear protective clothing gloves and safety glasses when working near chemical dosing pumps When pumping chemicals make sure all tubes are securely attached to the fittings It is recommended...

Page 4: ...45 12 176 4 1 6 0 42 The ball valves are constructed in glass The body is made of fiber reinforced polypropy lene for strength and durability Reliability through simplicity All BlackStone pumps use t...

Page 5: ...ph 0 5 7 4 18 3 4 84 1 14 7 15 2 4 02 2 29 4 13 6 3 60 3 44 1 10 8 2 86 BL20 bar psi lph gph 0 5 7 4 18 3 4 84 1 14 7 15 2 4 02 2 29 4 13 6 3 60 BL7 Pump output with 120 strokes minute 0 0 2 0 4 0 6 0...

Page 6: ...i BL20 18 3 lph 4 8 gph 0 5 bar 7 4 psi Adjustable from 0 to 100 of maximum pump capacity MATERIAL PUMP CASING fiber reinforced polypropylene VALVES glass balls O rings in FPM FKM PUMPHEAD PVDF DIAPHR...

Page 7: ...e sure it is strong enough to support the weight of the entire system The ambient temperature of the pump when in operation should be between 0 and 50 C 32 to 122 F and should be protected from direct...

Page 8: ...ad from UNION CONNECTION ADAPTER DISCHARGE VALVE PUMP SUCTION VALVE ADAPTER FOOT VALVE FILTER Diagram for Rigid Pipe Hose The pump should be placed in a conven tional location that will allow easy acc...

Page 9: ...leakage the feed tank Allow some slack in the hose and be sure it is not kinked or twisted Slip a hose connector onto the hose over the head valve and up to the bottom of the threads ensuring it is f...

Page 10: ...nd pressures The maximum self priming height is 1 5 m 5 ft It is advisable to install a level con troller in order to stop the pump when feed tank liquid level is low Assembling the Hose to the Valve...

Page 11: ...Control potentiometer on the face of the pump al lows to adjust the flow up to 100 of the pump s rated capacity A LED indicator will light up each time a stroke begins Uphill Installation Suggested i...

Page 12: ...ssure is a combination of back pressure plus all of the other resistances to flow present in your system BlackStone Pumps are designed to dose their rated output at the operating rated pressure Theref...

Page 13: ...worn out or weakened due to the chemicals Pay par ticular attention for any signs of abrasion or discoloration Also check the connectors to ensure they are tight Replace if necessary with parts from...

Page 14: ...ormaldehyde Fruit Juice Pulp Fuel Oil Gallic Acid Gasoline Refined Glucose Glycerine or Glycerol Glycolic Acid 30 Hexane Hydrazine Hydrobromic Acid 20 Hydrochloric Acid Con centrated Partial Listing o...

Page 15: ...cid Photographic Solutions Plating Solutions Potassium Carbonate Potassium Bromide Potassium Chlorate Potassium Chloride Potassium Cyanide Potassium Ferrocyanide Potassium Hydroxide Potassium Nitrate...

Page 16: ...erferences Any variation introduced by the user to the supplied equipment may degrade the instruments EMC performance HI721008 Ceramic Weights 4 pcs HI721101 Pumphead O Ring 6screwsand washers HI72110...

Page 17: ...Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 011...

Reviews: