background image

25

24

MAINTENANCE

Your BlackStone Pump is designed to give
you years of trouble-free service. Mainte-
nance should be the preventative type, that
is, periodic cleaning and inspecting for any
damage or leakage.

Cleaning the Suction, Discharge and In-
jection Valves

Remove the valves from the pumphead,
the injection  fitting and the feed.

Keep the suction and discharge valves sepa-
rated as they are not interchangeable.

Disassemble each valve and clean it with a
neutral liquid. Inspect the PVDF springs.

After cleaning the glass balls, inspect them
for any excessive wear due to abrasion from
the chemical. Replace if necessary with parts
from HI 721102HI 721103HI 721104 and
HI 721105.

When reinstalling the valves into the
pumphead, tighten by hand first and then
with a wrench ¼ to ½ turn.

Inspecting the hose  (if used as supplied
with the pump)

Inspect to see if the hose has worn out or
weakened due to the chemicals. Pay par-
ticular attention for any signs of abrasion or
discoloration. Also check the connectors to
ensure they are tight.

Replace if necessary with parts from HI
720032
.

exceed 1.5 meters (5 feet). Either lower the
pump or raise the feed tank.

• Check  the  pumphead,  suction  and

discharge valves for blockage.

Pump flow rate is reduced:

• Check the pumphead, discharge and injec-

tion valve assembly for any clogging. Clean
and reassemble.

• Check for any additional back pressure cre-

ated since the last flow rate was conducted.

• Check for any changes in the viscosity of

the chemicals being used. Increase the %
flow by adjusting the Flow Rate control to a
higher setting and run a Flow Rate test.

• Be sure that valves have been properly in-

stalled in the pumphead.

Leakage at the connections:

 Be sure that the hose is fully seated and

hose connectors are tight.

 Be sure that valves are tight and O-rings

are in place.

Leakage around the pumphead:

• Be sure that the valves are tight and O-

rings are in place and the head screws
(hex bolts) are tight.

Summary of Contents for BL Series Pumps

Page 1: ...Instruction Manual BL1 5 BL3 BL5 BL7 BL10 BL15 BL20 Dosing Pumps w w w h a n n a i n s t c o m...

Page 2: ...itch Dear Customer Thank you for choosing a Hanna product Please read this instruction manual carefully before using the pump If you need additional technical information do not hesitate to e mail us...

Page 3: ...mp Always wear protective clothing gloves and safety glasses when working near chemical dosing pumps When pumping chemicals make sure all tubes are securely attached to the fittings It is recommended...

Page 4: ...45 12 176 4 1 6 0 42 The ball valves are constructed in glass The body is made of fiber reinforced polypropy lene for strength and durability Reliability through simplicity All BlackStone pumps use t...

Page 5: ...ph 0 5 7 4 18 3 4 84 1 14 7 15 2 4 02 2 29 4 13 6 3 60 3 44 1 10 8 2 86 BL20 bar psi lph gph 0 5 7 4 18 3 4 84 1 14 7 15 2 4 02 2 29 4 13 6 3 60 BL7 Pump output with 120 strokes minute 0 0 2 0 4 0 6 0...

Page 6: ...i BL20 18 3 lph 4 8 gph 0 5 bar 7 4 psi Adjustable from 0 to 100 of maximum pump capacity MATERIAL PUMP CASING fiber reinforced polypropylene VALVES glass balls O rings in FPM FKM PUMPHEAD PVDF DIAPHR...

Page 7: ...e sure it is strong enough to support the weight of the entire system The ambient temperature of the pump when in operation should be between 0 and 50 C 32 to 122 F and should be protected from direct...

Page 8: ...ad from UNION CONNECTION ADAPTER DISCHARGE VALVE PUMP SUCTION VALVE ADAPTER FOOT VALVE FILTER Diagram for Rigid Pipe Hose The pump should be placed in a conven tional location that will allow easy acc...

Page 9: ...leakage the feed tank Allow some slack in the hose and be sure it is not kinked or twisted Slip a hose connector onto the hose over the head valve and up to the bottom of the threads ensuring it is f...

Page 10: ...nd pressures The maximum self priming height is 1 5 m 5 ft It is advisable to install a level con troller in order to stop the pump when feed tank liquid level is low Assembling the Hose to the Valve...

Page 11: ...Control potentiometer on the face of the pump al lows to adjust the flow up to 100 of the pump s rated capacity A LED indicator will light up each time a stroke begins Uphill Installation Suggested i...

Page 12: ...ssure is a combination of back pressure plus all of the other resistances to flow present in your system BlackStone Pumps are designed to dose their rated output at the operating rated pressure Theref...

Page 13: ...worn out or weakened due to the chemicals Pay par ticular attention for any signs of abrasion or discoloration Also check the connectors to ensure they are tight Replace if necessary with parts from...

Page 14: ...ormaldehyde Fruit Juice Pulp Fuel Oil Gallic Acid Gasoline Refined Glucose Glycerine or Glycerol Glycolic Acid 30 Hexane Hydrazine Hydrobromic Acid 20 Hydrochloric Acid Con centrated Partial Listing o...

Page 15: ...cid Photographic Solutions Plating Solutions Potassium Carbonate Potassium Bromide Potassium Chlorate Potassium Chloride Potassium Cyanide Potassium Ferrocyanide Potassium Hydroxide Potassium Nitrate...

Page 16: ...erferences Any variation introduced by the user to the supplied equipment may degrade the instruments EMC performance HI721008 Ceramic Weights 4 pcs HI721101 Pumphead O Ring 6screwsand washers HI72110...

Page 17: ...Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 011...

Reviews: