Power Requirements

BlackStone pumps  are designed to operate
to specifications within the following voltage
ranges:

100 - 130 Volts for -1 models

200 - 240 Volts for -2 models

To ensure maximum performance, check the
voltage at the point of supply to verify that it
is sufficient. It is recommended that you in-
stall a 1 Amp circuit breaker between the
pump and the power supply. This will give
additional protection to the internal circuit
and provide a convenient way to disconnect
the power supply prior to servicing the pump,
if needed.

Injection Point

• Choose an injection point that allows you

to mount the injection valve assembly ver-
tically.

• The spring in the injection valve assembly

(HI 721004) adds approximately 1.5 bar of
back pressure. If pumping into a high back
pressure, the spring should be removed.

Other Considerations

• If you are mounting the system to a wall,

column, etc., be sure it is strong enough
to support the weight of the entire system.

• The ambient temperature of the pump,

when in operation, should be between 0
and 50°C (32 to 122°F) and should be
protected from direct exposure to outdoor
elements (direct sunlight, rain, extreme tem-
peratures, high humidity, etc.).

• Generally speaking, the shorter the suction

distance, the more efficient the pump oper-
ates.

INSTALLATION

Materials Needed

• LDPE hose (7 meter / 22 feet) (included)

or other type of tubing (PTFE, for example)
more suitable for a specific application (op-
tional)

Optional Accessories

• 4 each, ceramic weights (HI 721008)

• 1 each, foot valve assembly (HI 721005)

• 1 each, injection valve assembly (HI 721004)

Location

A suitable location should:

 be near to a power source
 be conveniently close to the injection point
 allow easy access to the flow rate control

and pipe or hose connections

 be no more than 1.5 meters (5 feet) above

the operating position of the suction valve
assembly.

Dimensions for Installation

BlackStone pumps are designed for perma-
nent installation.

The pump can be mounted directly on a wall
or tank.

Summary of Contents for BL Series Pumps

Page 1: ...Instruction Manual BL1 5 BL3 BL5 BL7 BL10 BL15 BL20 Dosing Pumps w w w h a n n a i n s t c o m...

Page 2: ...itch Dear Customer Thank you for choosing a Hanna product Please read this instruction manual carefully before using the pump If you need additional technical information do not hesitate to e mail us...

Page 3: ...mp Always wear protective clothing gloves and safety glasses when working near chemical dosing pumps When pumping chemicals make sure all tubes are securely attached to the fittings It is recommended...

Page 4: ...45 12 176 4 1 6 0 42 The ball valves are constructed in glass The body is made of fiber reinforced polypropy lene for strength and durability Reliability through simplicity All BlackStone pumps use t...

Page 5: ...ph 0 5 7 4 18 3 4 84 1 14 7 15 2 4 02 2 29 4 13 6 3 60 3 44 1 10 8 2 86 BL20 bar psi lph gph 0 5 7 4 18 3 4 84 1 14 7 15 2 4 02 2 29 4 13 6 3 60 BL7 Pump output with 120 strokes minute 0 0 2 0 4 0 6 0...

Page 6: ...i BL20 18 3 lph 4 8 gph 0 5 bar 7 4 psi Adjustable from 0 to 100 of maximum pump capacity MATERIAL PUMP CASING fiber reinforced polypropylene VALVES glass balls O rings in FPM FKM PUMPHEAD PVDF DIAPHR...

Page 7: ...e sure it is strong enough to support the weight of the entire system The ambient temperature of the pump when in operation should be between 0 and 50 C 32 to 122 F and should be protected from direct...

Page 8: ...ad from UNION CONNECTION ADAPTER DISCHARGE VALVE PUMP SUCTION VALVE ADAPTER FOOT VALVE FILTER Diagram for Rigid Pipe Hose The pump should be placed in a conven tional location that will allow easy acc...

Page 9: ...leakage the feed tank Allow some slack in the hose and be sure it is not kinked or twisted Slip a hose connector onto the hose over the head valve and up to the bottom of the threads ensuring it is f...

Page 10: ...nd pressures The maximum self priming height is 1 5 m 5 ft It is advisable to install a level con troller in order to stop the pump when feed tank liquid level is low Assembling the Hose to the Valve...

Page 11: ...Control potentiometer on the face of the pump al lows to adjust the flow up to 100 of the pump s rated capacity A LED indicator will light up each time a stroke begins Uphill Installation Suggested i...

Page 12: ...ssure is a combination of back pressure plus all of the other resistances to flow present in your system BlackStone Pumps are designed to dose their rated output at the operating rated pressure Theref...

Page 13: ...worn out or weakened due to the chemicals Pay par ticular attention for any signs of abrasion or discoloration Also check the connectors to ensure they are tight Replace if necessary with parts from...

Page 14: ...ormaldehyde Fruit Juice Pulp Fuel Oil Gallic Acid Gasoline Refined Glucose Glycerine or Glycerol Glycolic Acid 30 Hexane Hydrazine Hydrobromic Acid 20 Hydrochloric Acid Con centrated Partial Listing o...

Page 15: ...cid Photographic Solutions Plating Solutions Potassium Carbonate Potassium Bromide Potassium Chlorate Potassium Chloride Potassium Cyanide Potassium Ferrocyanide Potassium Hydroxide Potassium Nitrate...

Page 16: ...erferences Any variation introduced by the user to the supplied equipment may degrade the instruments EMC performance HI721008 Ceramic Weights 4 pcs HI721101 Pumphead O Ring 6screwsand washers HI72110...

Page 17: ...Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 011...

Reviews: