Replacing Meter
1.
Unplug electrical cord from outlet.
2.
Turn off water supply to system.
3.
Relieve water pressure in the system by putting the valve in the Backwash position
momentarily.
4.
Return the valve to the In Service position.
5.
Pull cable out of meter cover.
6.
Remove two screws and clips at bypass valve or yoke.
7.
Pull resin tank away from plumbing connections.
8.
Remove two screws and clips at control valve.
9.
Pull meter module out of control valve.
10.
Apply silicone lubricant to four new O-rings and assemble to four ports on new meter module.
11.
Assemble meter to control valve.
Meter portion of module must be assembled at valve outlet.
12.
Attach two clips and screws at control valve. Be sure clip legs are firmly engaged with lugs.
13.
Push resin tank back to the plumbing connections and engage meter ports with bypass valve or
yoke.
14.
Attach two clips and screws at bypass valve or yoke. Be sure clip legs are firmly engaged with
lugs.
15.