HD / HDL Valves & Systems Service Manual
Hankscraft Runxin, LLC 300 Wengel Drive 608.524.9465 hrh2o.com [email protected]
41
3.
Relieve water pressure in the system by putting the valve in the Backwash position momentarily.
4.
Return the valve to the In Service position.
5.
Pull cable out of meter cover.
6.
Remove the valve back cover.
7.
Remove screw and washer at drive yoke.
8.
Remove timer mounting screws. The entire timer assembly should lift off easily.
9.
Put new timer on top of valve. Be sure drive pin on main gear engages slot in drive yoke (rotate
control know if necessary).
10.
Replace timer mounting screws
11.
Replace screw and washer at drive yoke.
12.
Return bypass to normal In Service position. Water pressure automatically builds in the system.
Be sure to shut off any bypass line.
13.
Plug electrical cord into outlet.
14.
Set time of day.
15.
Return the control valve to the In Service position.
16.
Replace the control valve back cover. Be sure grommet at cable hole is in place.
Make sure there is enough brine in the brine tank.
17.
Rotate program wheel counterclockwise until it stops at Regeneration position.
18.
Start regeneration cycle manually if water is hard.
19.
Plug cable into meter cover. Rotate cable to align drive flat if necessary.