39
B
Emergency measures
The operator in the basket getting ill or losing control ability
In the event that the operator becomes ill or loses control ability, the person on the
ground can gain control of the lift through the ground control panel. Follow the
instructions below:
-Call the medical emergency station. Then, turn the key switch 1 on the control panel to
position C (Figure A) to gain control of the lift.
-Operate the AWP to lower it.
An accident or a fault occurring to the lift
-Open the right cover.
-Evacuate the operators under the basket.
-When you are unable to operate by using the control box due to a fault occurring on
the lift, all movements can be made by manual release.
-Open the right cover.
-When you need the lift to move, loosen the electromagnetic valve associated with the
movement on the main hydraulic valve (Figure B) and simultaneously operate the hand
pump up and down (Figure D).
Notice: For emergency lowering, retract the telescopic boom first and then lower the upper boom.