INSTALLATION AND ADJUSTMENT
9
§3 Installation and Adjustment
§3.1 Parameters
Model
Parameters
HSG200 (220VAC)
Input Voltage
(
V
)
1~208-240
±5%
Input Current
(
A
)
20 (max.)
Input Power
(
KW
)
5.7
Welding Current
(
A
)
50~200
No-load Voltage
(
V
)
57
Duty cycle
(
4
0℃)
25%200A
100%120A
Diameter(mm)
Fe
:
0.6/0.8/0.9 SS: 0.6/0.8/0.9 Flux-Cored
:
0.8/0.9/1.0
Protection class
IP23
Insulation class
H
Dimensions
(
mm
)
465*214*395
Weight
(
Kg
)
12.5 Kg.
Note: The above parameters are subject to chan.
§3.2 Duty cycle and Over-temp
The CSA/UL rated duty cycle is defined as the proportion of the time that a machine can work
continuously over a 10 minute cycle when set at 100% of rated output welding current in 40C
(104F) ambient environment.
When the transformer reaches an over-heat condition, the heat sensor inside it will open and
will output an instruction to circuit board to cut AC relay and the output welding current while
illuminating the over-heat pilot lamp in the front panel. At this time, all welding operations should
cease for 15 minutes allowing the cooling fan to reduce the temperature. The unit will auto-reset
when correct temperature has been achieved and pilot light will go out. If the machine reached
the over-temp capacity again, the welding output current or the arc cycle should be reduced.