- 15 -
2.2.4 Components Position
1-Pasteurizer cover
2-Rinse spigo 3-Valve wrench
4-Inlet cover
5-Emergency stop button
6-Cylinder door
7-Output wrench
8-Door latch
9-Output groove 10-Water tap
11-Pan holder 12-Pasteurizer tank
13-Beating motor of pasteurizer 14-Driving wheel
15-Bearing holder
16-Cylinder
17-Dasher motor 18-Inverter (optional installed) 19-Electrical component box
20-Compressor
21-
Thermal expansion valve 22-
Condenser 23-
Reservoir
24-Filter
25-Wheel
2.3 Working Conditions
The following conditions are requested to ensure long term and steady operation:
◇
Voltage
Fluctuation: ≤ ±10%
◇
Min ambient temperature: 10°C
◇
Max ambient temperature: 43°C
◇
Min cooling water temperature: 10°C
◇
Max cooling water temperature: 30°C
◇
Min water pressure: 1 bar
◇
Max water pressure: 8 bar
◇
Max relative humidity: 85% ( without moisture condensation)
The machine is not designed with anti-explosion standards.
Thus make sure the working place is out of explosive danger.
_________________________________________________________________
WARNING
H&M is NOT responsible for any accident happened to people or machine in case
the machine is used out of the designed condition.
_________________________________________________________________