High intensity” red or green indicates the achieved grade
Right-click the “LED” area to select the minimum passing ISO/IEC
grade.
Format Parameters
•
Check Digit
•
Pass/Fail/Not Applicable Indicator (P, F, or N/A) and visual indicator
(red, green, gray)
Right-click the Check Digit “circle” to turn on or off optional check
digit validation (for Code 39, Interleaved 2-of-5, Codabar).Message
Length
•
Number of characters in the message
•
Pass/Fail Indicator (P or F) and visual indicator (red or green) for
message length check.
Right-click the Message Length display to select fixed or variable
messages.
Dimensional Parameters
•
Decodability (ISO/IEC)
•
Visual reference for pass/fail levels (red and green bars within
display window)
•
Measured parameter level (blue indicator within display window)
•
Measured parameter numeric value
•
Alphabetic grade A-F
•
Visual Pass/Fail indicator (Alphabetic Grade background displays
green or red)
•
Intercharacter Gap (ICG)
•
Displays ICG as a multiple of the X dimension
•
Pass/Fail indicator
•
Visual Pass/Fail indicator (Pass/Fail background displays green or
red)
•
Wide-to-Narrow Ratio (W/N Ratio)
•
Displays Wide-to-Narrow Ratio
•
Pass/Fail indicator
•
Visual Pass/Fail indicator (Pass/Fail background displays green or
red)
Right-click the W/N Ratio area to select the allowable ratio for the
following two-width symbologies
16