: Code 39
: Interleaved 2-of-5 (ITF, I 2/5)
: Codabar
•
Average Bar Error
•
Numeric measure of bar width deviation as a multiple of the X
dimension
•
Pass/Fail indicator
•
Visual Pass/Fail indicator (Pass/Fail background displays green or
red)
•
Bar Width “LED” display
•
Five LEDs indicates bar width growth or reduction as a percentage
of traditional bar width tolerance:
: “Reject -” (red), FAILED, bars too narrow
: “-” (yellow), CAUTION, bar width reduction evident
: “In Spec” (green), PASSED, bar width okay
: “+”(yellow), CAUTION, bar growth evident
: “+ Reject “ (red), FAILED, excessive bar growth
Note
: LED indicators may be displayed in pairs, such as a yellow and
green, to indicate intermediate levels of bar growth or reduction is evident.
Note
:
The table below shows the bar width variances corresponding to
the “LED” displays.
Red:
more than -100% of tolerance
Red+Yellow: -75% to -100 % of tolerance
Yellow: -50% to -75% of tolerance
Green:
-25% to -50% of tolerance
Green: -25% to +25% of tolerance
Green+Yellow:
+25% to +50% of tolerance
Yellow: +50% to +75% of tolerance
Red: +75% to +100 % of tolerance
Red:
more than +100% of tolerance
Additional Data
The lower right-hand portion of the screen provides two lines of display for
information not displayed elsewhere. The scroll arrows allow you to step through
multiple messages.