Keyboard shortcut or operation
IF YOU DO NOT HAVE AN AVAILABLE COM PORT: STOP!
For computers with USB and parallel ports (no serial ports) you can use a USB to
serial converter (USB on PC end, male serial on end that connects to the
QCDB09F female 9-pin serial port or a PC Card (PCMCIA) with a male serial
adapter.
You may not connect the Quick Check
®
PC device to your mouse serial port
unless you have a Windows
®
keyboard with the additional Windows function
keys. A mouse is required for optimal Quick Check
®
PC software operation.
•
Do not connect the Quick Check
®
PC interface module to COM 3 unless
the port uses a different interrupt (IRQ) than COM 1. COM 1 and COM
3 typically share the same interrupts and erratic performance of both the
mouse and the Quick Check
®
PC software will result if there is an IRQ
conflict.
Note
: You can install the Quick Check
®
PC software on a PC that does not
have an available COM port if you do not intend to connect the interface unit.
Installing the Quick Check
®
PC software allows supervisory or quality personnel
to review results (files) at a location other than where symbols are verified. If you
choose this option, an advisory message in the lower left corner of the Quick
Check
®
PC screen will indicate “No Port Selected.” This is the default setting for
the software.
IF YOU DO HAVE AN AVAILABLE COM PORT:
Insert the 4 AA NiCad batteries into the back (base) of the interface module. You
must insert the batteries before connecting the AC charger.
•
Make sure the batteries are installed correctly. Incorrect installation
could damage the device.
•
Use only NiCad rechargeable batteries. Do not use alkaline or
other types of batteries. Do not mix old and new batteries.
FAILURE TO FOLLOW THESE PROCEDURES MAY RESULT IN
EXPLOSION OF BATTERIES, DAMAGE TO THE EQUIPMENT, AND/OR
PERSONAL INJURY.
2. Select the cable that has an RJ-45 plug on one end and the proper serial
connection for your communications port on the other.
•
Plug the “phone jack” into the Quick Check
®
interface module.
•
Connect the serial connector to your communications port.
•
If your serial port has a 25 pin connector, a 9 to 25 pin adapter should
be used.
3. Plug the power adapter into a working outlet and into the interface module.
4. Connect the Pen Wand or Mouse Wand to the interface module
7