Intercharacter, Interfunction, and Intermessage Delays
Some terminals drop information (characters) if data comes through too quickly.
Intercharacter, interfunction, and intermessage delays slow the transmission of
data, increasing data integrity.
Each delay is composed of a 5 millisecond step. You can program up to 99 steps
(of 5 ms each) for a range of 0-495 ms.
Intercharacter Delay
An intercharacter delay of up to 495 milliseconds may be placed between the
transmission of each character of scanned data. Scan the
Intercharacter Delay
bar code below, then scan the number of milliseconds and the
SAVE
bar code
using the
Programming Chart
inside the back cover of this manual.
To remove this delay, scan the
Intercharacter Delay
bar code, then set the
number of steps to 0. Scan the
SAVE
bar code using the
Programming Chart
inside the back cover of this manual.
Note: Intercharacter delays are not supported in USB serial emulation.
1
2
3
4
5
Intercharacter Delay
Prefix
Scanned Data
Suffix
Intercharacter Delay
Summary of Contents for 2020
Page 1: ...IMAGETEAM 2020 4620 Area Imager Cordless System System Manual...
Page 7: ...Required Safety Labels www handheld com B IT4620...
Page 20: ...xii...
Page 56: ...2 26 IMAGETEAM 2020 4620 System Manual...
Page 70: ...3 14 IMAGETEAM 2020 4620 System Manual...
Page 90: ...4 20 IMAGETEAM 2020 4620 System Manual...
Page 98: ...5 8 IMAGETEAM 2020 4620 System Manual...
Page 154: ...7 50 IMAGETEAM 2020 4620 System Manual...
Page 164: ...8 10 IMAGETEAM 2020 4620 System Manual...
Page 179: ...IMAGETEAM 2020 4620 System Manual 9 15 Exit Selections Save OCR Template Discard OCR Template...
Page 180: ...9 16 IMAGETEAM 2020 4620 System Manual...
Page 239: ......
Page 240: ......
Page 241: ......
Page 245: ...OCR Programming Chart a e d g c h t l Discard Save r...