background image

HANBAY Inc 

 

             User Manual MDx-xxxDT-10.31 

Page 1 of 8 

www.hanbayinc.com                       

  

     

Rev: 2 

– July, 2019

 

1 800 315 4461 

 

[email protected]

       

 

MDx-xxxDT-10.31   

  

     

 

 

Contents

 

 
Installation 

 

 

pg. 1-3 

 

Mounting  

 

 

pg 1 

 

Wiring    

 

 

pg 2 

 

Connecting power and signal  

pg 2-3 

 
Operation 

 

 

pg. 3-5 

 

DIP Switch settings  

 

pg 3-4 

 

Functionality  

 

 

pg 4 

Torque Settings   

  

pg 5 

 

Setting the type of actuator 

pg 6 

Calibration  

 

 

pg 6 

 

Troubleshooting  

 

pg 6 

 
Appendix 

     

 

pg. 6-7 

 

Dimensions  

 

 

pg 7 

 

Cable Installation  

 

pg 7 

 
Part Number Breakdown 

pg. 8 

 
 

Installation 

 
 
 

Mounting: 

 

Usually, the actuator has to be mounted and supported as 
shown in the picture to the left. 
Exceptionally, and only if the application is vibration free and 
the tubing is minimum ¼” dia. stainless, the actuator may be 
suspended on the tubing itself. 

 
 
 
 
 
 
 
 

 
 

 
 

Mounting 
Bracket 

Attachment Screws 
8-

32 x 1/2” 

User’s mounting 
surface

 

Valve fluid 
connections 

Cable 
Entry 

Summary of Contents for MD DT-10.31 Series

Page 1: ...ting the type of actuator pg 6 Calibration pg 6 Troubleshooting pg 6 Appendix pg 6 7 Dimensions pg 7 Cable Installation pg 7 Part Number Breakdown pg 8 Installation Mounting Usually the actuator has t...

Page 2: ...color schematic for Turck6 cable Otherwise if the Turck cable is not included in your actuator see pg 8 for more detailed wiring instructions Pin Colour Function 6 White 24VDC 5 Black Power Gnd 4 Pin...

Page 3: ...to use a fast settling setting on a high torque valve will increase current consumption when holding position and cause heating of the motor DIP 1 DIP 2 Off Off Fastest settling Use only for low torq...

Page 4: ...Off On Medium low 33 1A On Off Medium high 66 2A On On High torque 100 3A Approximate stall torque DIP 10 DIP 11 MDL MDM MDH MDF Off Off 55 in lbs 120 in lbs 405 in lbs 756 in lbs Off On 82 in lbs 16...

Page 5: ...e input is used to operate the valve When the actuator is operated using input 1 an automatic calibration is done every time the valve is actuated This does not happen on input 2 Torque Settings Effec...

Page 6: ...he actuators output gear gets manually rotated while the actuator is powered down and can t properly realign to the center by itself Troubleshooting Upon noticing a problem your first step should almo...

Page 7: ...ight fitting from the actuator casing and insert the cable into it 4 Carefully insert the cable into the actuator base Mind the red motor cable and its plug into the board Moving the plug out of its f...

Page 8: ...HANBAY Inc User Manual MDx xxxDT 10 31 Page 8 of 8 www hanbayinc com Rev 2 July 2019 1 800 315 4461 hanbaysales hanbayinc com Part Number Breakdown Serial Number Full Hanbay Part Number...