SAFETY LABEL

NOTE: Hampton

®

 units are constantly being 

improved. Check the label on the unit and if 
there is a difference, the label on the unit is 
the correct one.

COPY OF SAFETY LABEL

                         

                    

                         

Listed: VENTED GAS FIREPLACE HEATER /
FOYER AU GAZ À ÉVACUATION

Certifi ed for/Certifi ée pour: CANADA and U.S.A.
WN# 16478 
Tested to: CGA 2-17-M91, ANSIZ21.88a-2007/CSA 2.33a-2007

MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE

DO NOT REMOVE THIS LABEL / NE 
PAS ENLEVER CETTE ÉTIQUETTE 

Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifi ce size
Altitude

Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifi ce size
Altitude

5"    WC/C.E. (1.25 kPa)
3.8" WC/C.E. (0.94 kPa)
1.1" WC/C.E. (0.27 kPa)
36,000 Btu/h (10.55 Kw/h)
18,000 Btu/h (5.28 Kw/h)
#33 DMS        (2.87mm)
0-4500 ft/pi   (0-1372m)

Pression d'allimentation minimum
Pression à la tubulure d'échappement élevée
Pression à la tubulure d'échappement basse
Débit Calorifi que maximum
Débit Calorifi que minimum
Dimensions de l’orifi ce
L’altitude

Pression d'allimentation minimum
Pression à la tubulure d'échappement élevée
Pression à la tubulure d'échappement basse
Débit Calorifi que maximum
Débit Calorifi que minimum
Dimensions de l’orifi ce
L’altitude

FACTORY EQUIPPED FOR NATURAL GAS 

Model:H35-NG2

Convertible to 30,000
Orifi ce Size
Maximum Input
Minimum Input
Altitude

#37 DMS
30,000 Btu/h (8.78 Kw/h)
14,300 Btu/h (4.19 Kw/h)
0-4500 ft/pi (0-1372m)

Dimensions de l'orifi ce
Débit Calorifi que maximum selon
Débit Calorifi que minimum selon
L’altitude

Dimensions de l'orifi ce
Débit Calorifi que maximum selon
Débit Calorifi que minimum selon
L’altitude

FACTORY EQUIPPED FOR PROPANE GAS 

Model:H35-LP2

12"    WC/C.E. (3.00 kPa)
11" WC/C.E.    (2.74 kPa)
2.9" WC/C.E.   (0.72 kPa)
34,000 Btu/h (9.97 Kw/h)
17,500 Btu/h (5.13 Kw/h)
#51 DMS        (1.70mm)
0-4500 ft/pi   (0-1372m)

Convertible to 28,500 Btu

Orifi ce Size
Maximum Input
Minimum Input
Altitude

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas 
and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured 
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCS-
BCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, 
manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. 
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, Na-
tional Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 
CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCS-
BCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational 

Vehicles.

Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison 
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de 
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifi ée est fournie. 
This vented gas fi replace heater is not for use with air fi lters.          Ne pas utiliser de fi ltre à air avec ce foyer au gaz à évacuation.                                                                                          
For use with glass doors certifi ed with the appliance only                Pour utilisation uniquement avec les portes en verre certifi ées avec l'appareil

Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.    

  NOT FOR USE WITH SOLID FUELS. / NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE

FPI Fireplace Products International Ltd. Delta, BC, Canada            Made in Canada/Fabrique au Canada                  918-840

Minimum Clearances to Combustibles/Degagement 
Minimum De Materiaux Combustibles
Minimum ceiling height from top of unit:36”/914mm
Minimum plafond hauteur en haut de l’appareil: 

A  6-1/2”/165mm
B  6”/152mm

Minimum clearance of Vent Terminal to Outside Corner & Inside Corner: 
with AstroCap 6"/150mm with Dura-Vent Cap 12"/300mm

C  2" / 50mm
E  2"/50mm

Serial No./ No de serie

E

E

A

A

Left Side Wall

Right Side Wall

Vertical

Pipe

A

A

B

C

Left Side Wall

Right Side Wall

Horizontal

Pipe

Model/Modele:

 

H35-NG2

Model/Modele:

 

H35-LP2

355

355

#52 DMS
28,500 Btu/h (8.35 Kw/h)
15,000 Btu/h (4.39 Kw/h)
0-4500 ft/pi (0-1372m)

ÉQUIPÉ A L'UISINE POUR GAZ NATURAL

ÉQUIPÉ A L'UISINE POUR GAZ PROPANE

DUPLICATE SERIAL NO.

For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of 
Massachusetts.

For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with 
battery back up in the same room where the gas appliance is installed.

Summary of Contents for H35-NG2

Page 1: ...supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from...

Page 2: ...VER WILL CAUSE BURNS GLASS UNTIL COOLED ALLOW CHILDREN TO TOUCH GLASS CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES ESPECIALLY THE FIREPLACE GLASS AND SHOULD STAYAW...

Page 3: ...n designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model H35 2 has been approved by Warnock Hersey for both safety and efficiency As it also bears...

Page 4: ...allation Checklist 7 Clearances to Combustibles 7 Locating Your Gas Stove 8 Manufactured Mobile Home Requirements 8 Combustion and Ventilation Air 8 Optional Fan Installation 8 Venting Introduction 9...

Page 5: ...e is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes See owner s...

Page 6: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Page 7: ...r use with other gases unless a certified kit is used INSTALLATION AND REPAIRS SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THIS APPLIANCE SHOULD BE INSTALLED REPAIRED INSPECTED BE FORE USE AND AT LEA...

Page 8: ...c DV Stove Horizontal Vent Kit d Dura Vent Termination Kit 5 Make gas connections Refer to the Gas Connection section Test the pilot Must be as per diagram in the Maintenance Instruction section If co...

Page 9: ...e cut or remove the 3 aluminum air intake pipes Hint for pushing fan down onto pins rub a bit of dish soap on the pins so the grommets will slide down more easily Check to make sure the fan is seated...

Page 10: ...Kit and the rigid pipe venting systems in combination with the DirectVentFreestandingGasStoves H35 NG2 and H35 LP2 have been tested and listed as direct vent heater systems by Warnock Hersey These uni...

Page 11: ...f center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air in...

Page 12: ...A N A N A Adjustable Length 3 10 Galvanized N A N A N A 4DAL N A TC 4DLT Adjustable Length 3 10 Black N A N A N A 4DALB N A TC 4DLTB Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A Adjustable...

Page 13: ...TM 4ST14 Snorkel Termination 36 46DVA HC N A N A N A N A TM 4ST36 Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK N A Horizontal Termination Kit B 46DVA KHA Changed Components 4DT...

Page 14: ...AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent Pro are registered and or proprietary trademarks of Simpson Dura Vent Co Inc This product h...

Page 15: ...ecombinationsofverticalrunswith horizontal terminations Maximum one 90O elbow two 45o elbows equal one 90o elbow All approved caps listed on page 12 may be used Propane and Natural Gas Residential Man...

Page 16: ...osition A Refer to the Conversion Kit to Lower BTU Rating section for de rating instructions Note If venting this appliance as per the diagrams shown in the two diagrams the unit must be derated using...

Page 17: ...et total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 8 feet total vertical a...

Page 18: ...etween 90o elbows is required Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Withtheseoptions max total pipelengthis30feetwithmin of6feettotalverticalandmax 6 feet...

Page 19: ...flex running the full length of the chimney See the Venting Arrangements chart below for minimum and maximum flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent...

Page 20: ...the 45o elbow willseatontoboththestartercollarand the 90o elbow Crimped section of rigid pipe seats into the 90o elbow Onlycuttheuncrimpedsideofpipe Dismantle all pipe sections including vent terminal...

Page 21: ...enter ing and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia flex liner out fully and get a trial fit of the liner onto the 4 dia starter collar 8 Cut the 4 dia flex liner...

Page 22: ...of the unit to the wall It is also important to note the wall thickness The wall thimble is suitable for 2 x 4 or 2 x 6 wall construc tion Selecttheamountofverticalrisedesiredfor vertical to horizont...

Page 23: ...pliance adaptor is installedontheunitatthefactory Assemble the desired combination of pipe and elbows to the appliance adaptor with pipe seams orientedtowardsthewallorceiling asmuch out of view as pos...

Page 24: ...re the connection between the vent pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe Use the two sheet metal screw...

Page 25: ...or performance issues not covered under warranty Silicone red RTV is optional INSTALLATION 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adaptor up tho...

Page 26: ...out doors and caps or plugs for cleanout tee fittings and ash dumps shall be secured in place and sealed before installing a Direct Vent system within the chimney If the appliance shuts off during ope...

Page 27: ...Orifice Size 33 DMS Convertible to Max Input Rating 30 000 Btu h Min Input Rating 14 300 Btu h Orifice Size 37 DMS Propane Max Input Rating 34 000 Btu h Min Input Rating 17 500 Btu h Orifice Size 51 D...

Page 28: ...ote Any damage due to carboning re sulting from improperly setting the aeration controls is NOT covered under warranty Note Aeration Adjustment should only be performed by an authorized Hamp ton Insta...

Page 29: ...ilot cap to expose the pilot orifice Remove the 2 screws push Burner Assembly to the left and lift out Burner Orifice Installation of LPG Conversion Kit 1 Shut off the gas supply 2 H35 2 Lift off the...

Page 30: ...d with the red o ring visible Fig 5 16 Reassemble the black protection cap Fig 6 WARNING Also check that the pilot and main burner injectors are appropriate for the gas type LPG Configuration Red o ri...

Page 31: ...e or place this in a convenient location away from the heat source 14 Tie up the loose wire with the wire clip Installation of the DC Sparker for the P90 Units Only 1 Locate the Piezo Ignitor situated...

Page 32: ...wire from kit 9 Plug the DC spark generator wires to the DC Sparker 10 Connect the ground wire to the DC Sparker mounting bracket 12 Mount the heat shield to the DC Sparker Secure into place with the...

Page 33: ...tu 1 918 148 Instruction Sheet 1 Shut off the gas supply 2 Open the front door Carefully remove the logs and lava rock Refer to manual for more detailed instructions 3 Remove burner by removing 2 scre...

Page 34: ...n the screws Vent Restrictor setting at Low Btu for Straight Horizontal Venting 13 Attach the label This unit has been con verted to on top of the Serial decal over the higher Btu information 14 Check...

Page 35: ...ure proper light off make sure flame flows smoothly from one end of burner to the other If there is any flame hesitation check that area for any blockage of the burner port F 0 2 4 7 E 02 45 A 02 43 G...

Page 36: ...lf and cast top can be adjusted by sliding it in or out Once in final position tighten 2 screws shown in step 2b as shown below 8 Repeat on other side 1 Lift off the Cast Top 3 Flip assembled shelf ov...

Page 37: ...power failure theburnerswitchandtheoptionalremotecontrol thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Caution Ensure that the wires do no...

Page 38: ...maximum wire length Note Preferableifthethermostatisinstalled on an interior wall Hampton offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat tha...

Page 39: ...unit the logs have been incorrectly positioned 7 The unit should never be turned off and on again without a minimum of a 60 second wait 1 Choose a convenient location on the wall to install the recei...

Page 40: ...air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplie...

Page 41: ...Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process WARNING CH...

Page 42: ...The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone...

Page 43: ...11 mm wrench 16 Remove valve to orifice nut with a 13 16 wrench 17 Remove inlet pipe with pipe wrench Note orientation of 90o elbow 18 Remove two 2 phillips head M5 screws on each side of the valve 1...

Page 44: ...xchanger Assy 47 Transition Box Assy Top Relief Door Assembly 50 W260260 Top Relief Frame Gasket 51 942 117 Top Relief Frame 52 W260280 Top Relief Plate Gasket 53 290 021 Top Relief Plate 54 Capscrew...

Page 45: ...470 Pilot Assembly Gasket 69 Valve Shield 70 Valve Bracket 71 Valve Gasket 72 Front Support 73 730 528 Rear Log Bracket Assy 75 402 935 Log Set 740 572 Ember Package 78 730 550 Burner Assy 740 546 Bas...

Page 46: ...Hampton H35 2 Direct Vent Freestanding Gas Stove 45 NOTES...

Page 47: ...46 Hampton H35 2 Direct Vent Freestanding Gas Stove NOTES...

Page 48: ...requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer d...

Page 49: ...__________________________________________ Printed in Canada Hampton is a trademark of FPI Fireplace Products International Ltd Hampton fireplace products are designed with reliability and simplicity...

Reviews: