22
Hampton
®
H35-2 Direct Vent Freestanding Gas Stove
Diagram 2a
Diagram 3
Below Grade Snorkel Installation
If the Snorkel Termination must be installed
below grade, i.e. basement application,
proper drainage must be provided to prevent
water from entering the Snorkel Termina-
tion. Refer to Vent Manufacturer Installation
instructions for details. Do not attempt to
enclose the Snorkel within the wall, or any
other type of enclosure.
3)
With the pipe attached to the stove, slide
the stove into its correct location, and mark
the wall for a 10" x 10" (inside dimensions)
square hole. The center of the square hole
should line up with the center line of the
horizontal pipe, as shown in diagram 3.
Cut and frame the 10 inch square hole
in the exterior wall where the vent will be
terminated. If the wall being penetrated is
constructed of non-combustible material, i.e.
masonry block or concrete, a 7" diameter
hole is acceptable.
*As specifi ed in CAN/
CSA B149.1 Installation
Code. Local codes or
regulations may require
different clearances.
Diagram 2
INSTALLATION
Diagram 1:
Hint: Apply
silicone to
female end.
HORIZONTAL
INSTALLATIONS
RIGID VENT SYSTEM
1)
Set the unit in its desired location. Check
to determine if wall studs or roof rafters
are in the way when the venting system is
attached. If this is the case, you may want
to adjust the location of the unit.
2)
Direct Vent pipe and fi ttings are designed
with special twist-lock connections to con-
nect the venting system to the appliance
fl ue outlet. A twist-lock appliance adaptor is
installed on the unit at the factory. Assemble
the desired combination of pipe and elbows
to the appliance adaptor with pipe seams
oriented towards the wall or ceiling, as much
out of view as possible. The fi nal position-
ing of the pipe and 90
o
elbow assembly is
determined by the mounting orientation of
the adaptor on the stove and twist-locked
for a solid connection.
b)
Horizontal runs of vent must be sup-
ported every three feet. Wall straps are
available for this purpose.
c)
Snorkel Terminations:
For installations requiring a vertical rise
on the exterior of the building, 14-inch
and 36-inch tall Snorkel Terminations
and the Riser Vent as shown in Diagrams
2 & 2a are available. Follow the same
installation procedures as used for stand-
ard Horizontal Termination. NEVER
install the snorkel upside down.
Note:
a)
Twist-lock procedure: Four indentations,
located on the female ends of pipes and
fi ttings, are designed to slide straight
onto the male ends of adjacent pipes
and fi ttings, by orienting the four pipe
indentations so they match and slide in
to the four entry slots on the male ends
(Diagram 1). Push the pipe sections
completely together, then twist-lock
one section clockwise approximately
one-quarter turn, until the two sections
are fully locked. The female locking lugs
will not be visible from the outside on
the Black Pipe or fi ttings. They may be
located by examining the inside of the
female ends.
NOTE: For best results and optimum per-
formance with each approved venting
system, it is highly recommended to
apply “Mill-Pac” sealant (supplied) to
every inner pipe connection. Failure
to do so may result in drafting or
performance issues not covered
under warranty. Silicone (red RTV)
is optional.