HAMPTON BAY H25-LP1 Owners & Installation Manual Download Page 6

6

Hampton

®

 H25-1 Direct Vent Freestanding Gas Stove

IMPORTANT MESSAGE  

SAVE THESE 

INSTRUCTIONS

The  Direct Vent Freestanding Gas Stove must 
be installed in accordance with these instruc-
tions. Carefully read all the instructions in this 
manual fi rst. Consult the building authority 
having jurisdiction to determine the need for a 
permit prior to starting the installation.

Note:  Failure to follow the instructions 

could cause a malfunction of the 
heater which could result in death, 
serious bodily injury, and/or prop-
erty damage.  Failure to follow these 
instructions may also void your fi re 
insurance and/or warranty.

Note: These instructions take precedence 

over Simpson Dura-Vent instruc-
tions.

SPECIFICATIONS

Fuels: 

H25-NG1 is approved for use with 
natural gas.

 

H25-LP1 is approved for use with liq-
uefi ed petroleum gases (propane).

Electrical:

  120V  A.C. system.

Optional Circulation Fan: 

 

 Variable 

speed, 

125/75.

Log Sets: 

 Ceramic fi bre, 4 per set.

Vent System:

 Coaxial (6-5/8" outer / 4" inner 

liner) rigid fl ue and termination cap.

INFORMATION FOR 

MOBILE / 

MANUFACTURED 

HOMES 

AFTER FIRST SALE

This Hampton

®

 product has been tested and 

listed by ITS Testing Services as a Direct Vent 
Wall Furnace to the following standards:  
CGA-2.17-M91, and ANS Z21.88b-2003/CSA 
2.33b-2003.

This Direct Vent System Appliance must be 
installed in accordance with the manufacturer's 
installation instructions and the Manufactured 
Home Construction and Safety Standard, Title 
24 CFR, Part 3280, or the current Standard of 
Fire Safety Criteria for Manufactured Home In-
stallations, Sites, and Communities ANSI/NFPA 
501A, and with CAN/CSA Z240-MH Mobile 
Home Standard in Canada.

INSTALLATION

This appliance installation must comply with the 
manufacturer's installation instructions and local 
codes, if any. In the absence of local codes fol-
low the current National Fuel Gas Code, ANSI 
Z223.1 and the current National Electrical Code 
ANSI/NFPA 70 in the U.S.A., and the current 
CAN/CGA B149 Gas Installation Code and the 
current Canadian Electrical Code CSA C22.1 
in Canada.

This Hampton

®

 Mobile/Manufactured 

Home Listed appliance comes factory 
equipped with a means to secure the 
unit.

This Hampton

®

 Mobile/Manufactured 

Home listed appliance comes equipped 
with a dedicated #8 ground lug to which 
an 18 gauge copper wire from the steel 
chassis ground must be attached.

This appliance may only be installed in 
an aftermarket permanently located, 
manufactured (USA only) or mobile 
home, where not prohibited by local 
codes.

This appliance is only for use with 
the type of gas indicated on the rating 
plate. This appliance is not convert-
ible for use with other gases, unless 
a certifi ed kit is used.

INSTALLATION AND REPAIRS 
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON. THIS AP-
PLIANCE SHOULD BE INSTALLED, 
REPAIRED, INSPECTED BEFORE 
USE AND AT LEAST ANNUALLY 
BY A QUALIFIED SERVICE PER-
SON.  MORE FREQUENT CLEAN-
ING MAY BE REQUIRED DUE TO 
EXCESSIVE LINT FROM CARPET-
ING, ETC.  IT IS IMPERATIVE THAT 
THE CONTROL COMPARTMENT, 
BURNERS AND CIRCULATING 
AIR PASSAGEWAYS OF THE AP-
PLIANCE BE KEPT CLEAN.

BEFORE YOU START

Safe installation and operation of this appli-
ance requires common sense, however, we 
are required by the Canadian Safety Standards 
and ANSI Standards to make you aware of the 
following:

1)

  Provide adequate clearances for servicing, 

proper operation and around the air openings 
into the combustion chamber. 

2)

  The appliance must be installed on a fl at, 

solid, continuous surface (e.g. wood, metal, 
concrete). This may be the fl oor, or it can be 
raised up on a platform to enhance its visual 
impact. The appliance may be installed on 
carpeting, tile, wood fl ooring or other com-
bustible material, because the appliance's 
base extends the full width and depth of the 
appliance. The  Direct Vent Freestanding 
Gas Stove can be installed in a wide variety 
of ways and will fi t nearly any room layout. 
It may be installed in a recessed position, 
framed out into the room, or across a cor-
ner.

3)

  The  Direct Vent Freestanding Gas Stove  is 

approved for alcove installations, which meet 
the clearances listed on in the "Clearance 
to Combustibles" section.  This unit is ap-
proved for manufactured home installations, 
see the "Manufactured Mobile Home Addi-
tional Requirements" section and "Venting 
Arrangments" section for the required vent 
arrangements. If installed into a manufac-
tured home the unit must be bolted down 
to the fl oor. 

4)

  This appliance is Listed for bedroom  instal-

lations when used with a Listed Millivolt 

DUE TO HIGH TEMPERATURES, 
THE APPLIANCE SHOULD BE 
LOCATED OUT OF TRAFFIC AND 
AWAY FROM FURNITURE AND 
DRAPERIES.

WARNING: FAILURE TO INSTALL 
THIS APPLIANCE CORRECTLY 
WILL VOID YOUR WARRANTY 
AND MAY CAUSE A SERIOUS 
HOUSE FIRE.

CHILDREN AND ADULTS SHOULD 
BE ALERTED TO THE HAZARDS 
OF HIGH SURFACE TEMPERA-
TURES, ESPECIALLY THE FIRE-
PLACE GLASS, AND SHOULD 
STAY AWAY TO AVOID BURNS 
OR CLOTHING IGNITION.  

YOUNG CHILDREN SHOULD 
BE CAREFULLY  SUPERVISED 
WHEN THEY ARE IN THE SAME 
ROOM AS THE APPLIANCE.  

CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT 
BE PLACED ON OR NEAR THE 
APPLIANCE. 

Summary of Contents for H25-LP1

Page 1: ...Y What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Fol...

Page 2: ...a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood replace at the ick of a switch The model H25 has been approved by Warnock Hersey for both safety a...

Page 3: ...Residential and Manufactured Homes Mobile Homes 21 Minimum Horizontal Termination Installations 21 Dura Vent Termination Kit 22 Horizontal Terminations 23 Vertical Terminations 24 Converting Class A...

Page 4: ...abel on the unit is the correct one For the State of Massachusetts installation and repair must be done by a plumber or gas tter licensed in the Commonwealth of Massachusetts For the State of Massachu...

Page 5: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Page 6: ...d manufactured USA only or mobile home where not prohibited by local codes This appliance is only for use with thetypeofgasindicatedontherating plate This appliance is not convert ible for use with ot...

Page 7: ...ction 3 Setventrestrictor Refertothe VentRestric tor Position section 4 Install venting a Check all venting requirements See Vent Restrictor Position to Rigid Pipe Venting Systems sections b Vertical...

Page 8: ...ction INSTALLATION OPTIONAL FAN INSTALLATION Fan Kit Contains Qty Description 1 Fan Assembly c w green wire attached 1 Thermodisc 1 power cord 2 2 1 4 x 20 hex nut 1 Fan Speed Control 1 Remove the rea...

Page 9: ...stove and secure with the 2 supplied bolts 2 1 4 20 hex head 12 Before re attaching the rear access panel the valve wires and the fan wires need to be connected Re connect the red and grey valve wires...

Page 10: ...Warnock Hersey Theseunitsusethe balanced ue technology Co Axial system The inner liner vents products ofcombustiontotheoutsidewhiletheouterpipe draws outside combustion air into the combus tion chambe...

Page 11: ...ap min 12 30cm with Riser Vent min 6 15cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent o...

Page 12: ...4DT AJB N A N A N A Adjustable Length 17 24 Galvanized Disc See 46DV 16A 917 N A from FPI N A N A N A N A Adjustable Length 17 24 Black Disc See 46DV 16AB 917B N A N A N A SV4LBA24 Adjustable Length 7...

Page 13: ...N A N A N A Mansonry Chimney Conversion Kit includes Cap Adapter 18 x18 Flashing 46DVA KCT 935 N A N A N A N A Wall Firestop 46DVA WFS 947 N A N A N A N A Colinear Flex Connectors 46DVA ADF 923F N A N...

Page 14: ...ll as Simpson Dura Vent Direct Vent GS American Metal Products Ameri Vent Direct Vent Security Secure Vent Selkirk Direct Temp AstroCapTM is a proprietary trademark of FPI Fireplace Products Internati...

Page 15: ...If the vent is ENCLOSED in a chase min size 9 x 9 maintain a 1 1 4 clearance to combustibles May be installed in Manufactured Mobile Homes after rst sale Horizontal Terminations for All Venting System...

Page 16: ...feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 feet total vertical...

Page 17: ...tween 90o elbows is re quired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Withtheseoptions max total pipelengthis30feetwithmin of6feettotalverticalandmax 6 feet...

Page 18: ...the Venting Arrangements chart below for minimum and maximum ue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various...

Page 19: ...Attachthe 45o elbowtotherigid pipe and ensure that the pipe length when cut with the 45o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats into the 90o elb...

Page 20: ...to prevent water from entering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia ex liner out fully and get a trial t of the liner onto the 4 dia starter collar 8 Cut the...

Page 21: ...ular requirements Determine the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the wall thickness Before cutting the vent hole through the wall en...

Page 22: ...through a wall ceiling or at the ter mination where the use of a restop or wall thimble reduces the required clearance to 1 Be sure to check the vent termination clearance requirements from decks win...

Page 23: ...s constructed of non combusti ble material i e masonry block or concrete a 7 diameter hole is acceptable Note a The horizontal run of vent should have a 1 4 inch rise for every 1 foot of run towards t...

Page 24: ...stallation NOTE For best results and optimum performance with each approved vent ing system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so...

Page 25: ...ing or performance issues not covered under warranty Silicone red RTV is optional 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Ro...

Page 26: ...secured in place and sealed before installing a Direct Vent system within the chimney If the appliance shuts off during operation contact a quali ed service person to de termine if a negative pressur...

Page 27: ...o the support using the eight metal screws provided Be sure there is at least a 2 inch overlap where the extension joins the support HIGH ELEVATION This unit is approved in Canada for altitude to 4500...

Page 28: ...mits speci ed on the safety label 6 When nished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 at screwdriver Note Screw should be snug but do...

Page 29: ...und 30 in 904 781 Velcro Hook Black Remove the 2 screws push Burner Assembly to the left and lift out 3 Pull off the pilot cap to expose the pilot ori ce Installation of the LPG Conversion Kit 1 Shut...

Page 30: ...wn in Fig 4 rotate the screw clockwise until snug do not overtighten 13 Verify that if the conversion is from NG to LPG the screw must be re assembled with the red o ring visible Fig 5 14 Re assemble...

Page 31: ...generator wire through the hole of the DC spark heat shield 2 First remove the Piezo Ignition Wire from the Piezo Ignitor Then remove the Piezo Ignitor from the control panel 7 Attach the ground wire...

Page 32: ...r to the diagrams If the logs are broken do not use the unit until they are replaced Broken logs can interfere with the pilot operation The gas log kit contains the following a Rear Log b Left Side Fr...

Page 33: ...ace at the front of the burner in and around where the embers are placed Avoid stacking platinum embers 7 Place the center cross log on the locating pin in the top of the rear log and position as show...

Page 34: ...ximum wire length Note Preferableifthethermostatisinstalled on an interior wall Hampton offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that...

Page 35: ...needed for the fan blower operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges INSTALLATION FINAL CHECK Before leaving this unit with the customer the in...

Page 36: ...ding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug INSTALLATION F...

Page 37: ...the glass while it is hot located at the top right hand corner rear of the stove 2 Turn gas control knob so indicator points to OFF position and allow 5 minutes for any gas in the combustion chamber t...

Page 38: ...e knob will not push in or turn by hand don t try to repair it call a quali ed service technician Force or attempted repair may result in a re or explosion D Do not use this appliance if any part has...

Page 39: ...t Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process WARNING C...

Page 40: ...ngs have been disturbed and conse quently loosened Also check mechanical supports such as Wall Straps or plumbers tape for rigidity 5 Verify proper operation after servicing LOG REPLACEMENT The unit s...

Page 41: ...alve assembly continue 14 Remove two 2 thermopile wires 15 Remove thermocouple with a 9 mm metric wrench 16 Remove pilot nut with an 11 mm wrench 17 Remove valve to ori ce nut with a 13 16 wrench 18 R...

Page 42: ...ption Part Description Part Description 50 W260260 Top Relief Frame Gasket 51 942 117 Top Relief Frame 52 W260280 Top Relief Plate Gasket 53 770 066F Top Relief Plate 54 Capscrew 1 4 x 1 3 4 NC 55 Sid...

Page 43: ...910 038 Pilot Assy S I T 3 ame NG 910 039 Pilot Assy S I T 3 ame LP 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 69 Valve Shield 70 Valve Bracket 71 260 042 Valve Gasket 73 Valve Cover Plate 74 V...

Page 44: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Page 45: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Page 46: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Page 47: ...requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer d...

Page 48: ...Serial No __________________________________________________________ Printed in Canada Hampton is a trademark of FPI Fireplace Products International Ltd Hampton replace products are designed with rel...

Reviews: