INSTALLATION

You will require the following components with 
your new  Direct Vent Freestanding Gas Stove. 
Please review your product to make sure you 
have everything you need. In the event that 
you are missing any part, contact your dealer. 

Note:  These are the minimum pieces re-

quired. Other parts may be required 
for your particular installation. See 
above for a list of vent parts.

If installing termination on a siding covered wall, 
a vinyl siding standoff or furring strips can be 
used in order to ensure that the termination is 
not recessed into siding.

The vinyl siding standoff is required for walls 
with vinyl siding.

Minimum components for a Dura-Vent
Horizontal Installation:

A) Dura-Vent Horizontal Termination Kit
B)  Wall Thimble (required for combustible 

walls)

Minimum components for a Dura-Vent
Vertical Termination:

D) Dura-Vent Vertical Termination Kit. See 

above for pipe lengths.

 

Diagram 2a

HORIZONTAL 

TERMINATIONS

1)

  Set the unit in its desired location. Check to 

determine if wall studs are in the way when 
the venting system is attached. If this is the 
case, you may want to adjust the location 
of the unit.

2)

  Assemble the desired combination of pipe 

and elbow to the appliance adapter with 
pipe seams oriented down. Offset the pipe 
seams as double seams in one place will 
cause the outer pipe to take an oval shape. 
Kit comes complete with 18" of straight vent 
- 6-5/8" dia. black outer pipe and 4" dia. inner 
vent. 

3)

  With the pipe attached to the stove, slide the 

stove into its correct location, and mark the 
wall for a   9-1/2" (inside dimensions) round 
hole. The center of the round hole should line 
up with the centerline of the horizontal pipe, 
as shown in diagram 1. Cut and frame the 
9-1/2 round hole in the exterior wall where 
the vent will be terminated. If the wall being 
penetrated is constructed of non-combusti-
ble material, i.e. masonry block or concrete, 
a  7" diameter hole is acceptable.

Note:

a)

  The horizontal run of vent should have a            

1/4 inch rise for every 1 foot of run towards 
the termination. Never allow the vent to run 
downward. This could cause high tempera-
tures and may present the possibility of a 
fi re.

b)

  The location of the horizontal vent termination 

on an exterior wall must meet all local and 
national building codes, and must not be 
blocked or obstructed. Refer to the "Exterior 
Vent Terminal Locations" section.

c)

 

Snorkel Terminations:

 

For installations requiring a vertical rise 
on the exterior of the building, 14-inch and 
36-inch tall Snorkel Terminations as shown 
in Diagram 2 are available, as well as the 
standard Riser Vent. Follow the same in-
stallation procedures as used for standard 
Horizontal Termination. NEVER install the 
snorkel upside down.

 

Diagram 1

*Diagram 2a: As specifi ed in CGA B149 Instal-
lation Code. Local codes or regulations may 
require different clearances.

Diagram 2b

NOTE: For Snorkel terminations  in ABOVE  

grade installations, follow national or 
local code requirements.

 

Below Grade Snorkel Installation

 

If the Snorkel Termination must be installed 
below grade, i.e. basement application, 
proper drainage must be provided to prevent 
water from entering the Snorkel Termination. 
Refer to Dura-Vent Installation instructions 
for details.. Do not attempt to enclose the 
Snorkel within the wall, or any other type of 
enclosure.

4)

  Install wall penetration heat shield in the 

center of the 9-1/2" round hole and attach 
with wood screws. The four wood screws 
provided should be replaced with appropri-
ate fasteners for stucco, brick, concrete, or 
other types of sidings. Diagram 3.

5)

   If installing termination on a siding covered 

wall, a vinyl siding standoff or furring strips 
must be used to ensure that the termination 
is not recessed into the siding.  Diagram 
3.

6)

  Take the Riser Vent terminal and separate 

the Backing Plate from the Riser Vent Front 
by removing 8 screws as shown in diagram 
4.

Diagram  3

Summary of Contents for H25-LP1

Page 1: ...Y What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Fol...

Page 2: ...a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood replace at the ick of a switch The model H25 has been approved by Warnock Hersey for both safety a...

Page 3: ...Residential and Manufactured Homes Mobile Homes 21 Minimum Horizontal Termination Installations 21 Dura Vent Termination Kit 22 Horizontal Terminations 23 Vertical Terminations 24 Converting Class A...

Page 4: ...abel on the unit is the correct one For the State of Massachusetts installation and repair must be done by a plumber or gas tter licensed in the Commonwealth of Massachusetts For the State of Massachu...

Page 5: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Page 6: ...d manufactured USA only or mobile home where not prohibited by local codes This appliance is only for use with thetypeofgasindicatedontherating plate This appliance is not convert ible for use with ot...

Page 7: ...ction 3 Setventrestrictor Refertothe VentRestric tor Position section 4 Install venting a Check all venting requirements See Vent Restrictor Position to Rigid Pipe Venting Systems sections b Vertical...

Page 8: ...ction INSTALLATION OPTIONAL FAN INSTALLATION Fan Kit Contains Qty Description 1 Fan Assembly c w green wire attached 1 Thermodisc 1 power cord 2 2 1 4 x 20 hex nut 1 Fan Speed Control 1 Remove the rea...

Page 9: ...stove and secure with the 2 supplied bolts 2 1 4 20 hex head 12 Before re attaching the rear access panel the valve wires and the fan wires need to be connected Re connect the red and grey valve wires...

Page 10: ...Warnock Hersey Theseunitsusethe balanced ue technology Co Axial system The inner liner vents products ofcombustiontotheoutsidewhiletheouterpipe draws outside combustion air into the combus tion chambe...

Page 11: ...ap min 12 30cm with Riser Vent min 6 15cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent o...

Page 12: ...4DT AJB N A N A N A Adjustable Length 17 24 Galvanized Disc See 46DV 16A 917 N A from FPI N A N A N A N A Adjustable Length 17 24 Black Disc See 46DV 16AB 917B N A N A N A SV4LBA24 Adjustable Length 7...

Page 13: ...N A N A N A Mansonry Chimney Conversion Kit includes Cap Adapter 18 x18 Flashing 46DVA KCT 935 N A N A N A N A Wall Firestop 46DVA WFS 947 N A N A N A N A Colinear Flex Connectors 46DVA ADF 923F N A N...

Page 14: ...ll as Simpson Dura Vent Direct Vent GS American Metal Products Ameri Vent Direct Vent Security Secure Vent Selkirk Direct Temp AstroCapTM is a proprietary trademark of FPI Fireplace Products Internati...

Page 15: ...If the vent is ENCLOSED in a chase min size 9 x 9 maintain a 1 1 4 clearance to combustibles May be installed in Manufactured Mobile Homes after rst sale Horizontal Terminations for All Venting System...

Page 16: ...feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 feet total vertical...

Page 17: ...tween 90o elbows is re quired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Withtheseoptions max total pipelengthis30feetwithmin of6feettotalverticalandmax 6 feet...

Page 18: ...the Venting Arrangements chart below for minimum and maximum ue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various...

Page 19: ...Attachthe 45o elbowtotherigid pipe and ensure that the pipe length when cut with the 45o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats into the 90o elb...

Page 20: ...to prevent water from entering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia ex liner out fully and get a trial t of the liner onto the 4 dia starter collar 8 Cut the...

Page 21: ...ular requirements Determine the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the wall thickness Before cutting the vent hole through the wall en...

Page 22: ...through a wall ceiling or at the ter mination where the use of a restop or wall thimble reduces the required clearance to 1 Be sure to check the vent termination clearance requirements from decks win...

Page 23: ...s constructed of non combusti ble material i e masonry block or concrete a 7 diameter hole is acceptable Note a The horizontal run of vent should have a 1 4 inch rise for every 1 foot of run towards t...

Page 24: ...stallation NOTE For best results and optimum performance with each approved vent ing system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so...

Page 25: ...ing or performance issues not covered under warranty Silicone red RTV is optional 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Ro...

Page 26: ...secured in place and sealed before installing a Direct Vent system within the chimney If the appliance shuts off during operation contact a quali ed service person to de termine if a negative pressur...

Page 27: ...o the support using the eight metal screws provided Be sure there is at least a 2 inch overlap where the extension joins the support HIGH ELEVATION This unit is approved in Canada for altitude to 4500...

Page 28: ...mits speci ed on the safety label 6 When nished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 at screwdriver Note Screw should be snug but do...

Page 29: ...und 30 in 904 781 Velcro Hook Black Remove the 2 screws push Burner Assembly to the left and lift out 3 Pull off the pilot cap to expose the pilot ori ce Installation of the LPG Conversion Kit 1 Shut...

Page 30: ...wn in Fig 4 rotate the screw clockwise until snug do not overtighten 13 Verify that if the conversion is from NG to LPG the screw must be re assembled with the red o ring visible Fig 5 14 Re assemble...

Page 31: ...generator wire through the hole of the DC spark heat shield 2 First remove the Piezo Ignition Wire from the Piezo Ignitor Then remove the Piezo Ignitor from the control panel 7 Attach the ground wire...

Page 32: ...r to the diagrams If the logs are broken do not use the unit until they are replaced Broken logs can interfere with the pilot operation The gas log kit contains the following a Rear Log b Left Side Fr...

Page 33: ...ace at the front of the burner in and around where the embers are placed Avoid stacking platinum embers 7 Place the center cross log on the locating pin in the top of the rear log and position as show...

Page 34: ...ximum wire length Note Preferableifthethermostatisinstalled on an interior wall Hampton offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that...

Page 35: ...needed for the fan blower operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges INSTALLATION FINAL CHECK Before leaving this unit with the customer the in...

Page 36: ...ding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug INSTALLATION F...

Page 37: ...the glass while it is hot located at the top right hand corner rear of the stove 2 Turn gas control knob so indicator points to OFF position and allow 5 minutes for any gas in the combustion chamber t...

Page 38: ...e knob will not push in or turn by hand don t try to repair it call a quali ed service technician Force or attempted repair may result in a re or explosion D Do not use this appliance if any part has...

Page 39: ...t Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process WARNING C...

Page 40: ...ngs have been disturbed and conse quently loosened Also check mechanical supports such as Wall Straps or plumbers tape for rigidity 5 Verify proper operation after servicing LOG REPLACEMENT The unit s...

Page 41: ...alve assembly continue 14 Remove two 2 thermopile wires 15 Remove thermocouple with a 9 mm metric wrench 16 Remove pilot nut with an 11 mm wrench 17 Remove valve to ori ce nut with a 13 16 wrench 18 R...

Page 42: ...ption Part Description Part Description 50 W260260 Top Relief Frame Gasket 51 942 117 Top Relief Frame 52 W260280 Top Relief Plate Gasket 53 770 066F Top Relief Plate 54 Capscrew 1 4 x 1 3 4 NC 55 Sid...

Page 43: ...910 038 Pilot Assy S I T 3 ame NG 910 039 Pilot Assy S I T 3 ame LP 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 69 Valve Shield 70 Valve Bracket 71 260 042 Valve Gasket 73 Valve Cover Plate 74 V...

Page 44: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Page 45: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Page 46: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Page 47: ...requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer d...

Page 48: ...Serial No __________________________________________________________ Printed in Canada Hampton is a trademark of FPI Fireplace Products International Ltd Hampton replace products are designed with rel...

Reviews: