Care and Maintenance (continued) 

Preventing Mosquitos 

□  If mosquitoes are a problem in your area, it is recommended to run the fountain as much as possible to prevent 

standing water, where mosquitoes breed. You may also add a few drops of anti-mosquito water treatment, available at 
your local home and garden store, to the fountain water. 

Preventing Water Damage 

□  To eliminate water damage to floors and/or surrounding fountain areas, check for leaks and excessive splashing after 

initial installation and on a regular basis. 

Repairing Leaks 

□  If your fountain develops a leak and a visible crack is detected, seal the crack with plastic epoxy or Clear Silicone II 

sealant. If the fountain leaks without a visible crack, turn the pump off, fill the fountain and let the fountain sit for one 
week. If there is a crack, it will appear white. Remember to keep the water ¾ full as water evaporates over time. 

CLEANING THE FOUNTAIN 

□  Do not use bleach as it may be harmful to pets and wildlife and may also damage the finish of the fountain. 
□  Clean the fountain monthly to prevent mineral deposits and contamination which may clog the pump. 
□  Disconnect the pump from the power source and empty the water from the fountain. Use any gentle household 

cleanser and a soft brush or cloth to clean the fountain. Avoid using any harsh chemicals, abrasives or rough 
scrubbing., as this could damage the finish on your fountain. The frequency of cleaning may vary depending on the 
location of your fountain. 

MAINTAINING THE PUMP 

□  Use a pre-filter on your pump, if available, to prevent it from clogging with leaves or other debris. 
□  Regular cleaning of the pump is necessary depending upon the environment in which it is operated. Clean the pump 

when it is visibly soiled or when a noticeable decrease in performance is detected. Failure to clean the pump will 
result in overheating of the pump. 

□  Although it is not required, pumps generally last longer if left running continuously as it reduces the wear from 

starting and stopping. 

CLEANING THE PUMP 

 

WARNING: 

Before cleaning, always disconnect the 

pump from the power source.

 

□  Disassemble the pump by removing the filter (1), flow regulator (2), and gland (3). Remove the impeller/rotor 

assembly (4) by gently pulling on the impeller blades. Use a soft cloth or brush to clean the area inside of the pump 
housing (5). Clean the flow regulator (2), filter (1), and impeller assembly (4) in warm soapy water. Reassemble the 
pump and inspect for proper operation.  

                                      

            

Summary of Contents for F10013AB

Page 1: ...hance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay Item 1000 527 851 Model F10013AB USE AND CARE GUIDE KIDS O...

Page 2: ...ump must be completely submerged for proper operation and cooling CAUTION Keep the plug dry Do not expose the plug to water or steam CAUTION Do not use the pump in water exceeding 86 F 30 C CAUTION Do...

Page 3: ...ther than normal application use or service including but not limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of r...

Page 4: ...missing or damaged parts If any parts are missing or damaged do not attempt to assemble or use the product Contact the Customer Service Team at 1 855 HD HAMPTON or visit www HAMPTONBAY com PACKAGE CON...

Page 5: ...the top of the fountain body Make sure the water outlet is facing away from the bucket of the fountain body and insert the top fountain B into the base A until the pieces are secured together Lead the...

Page 6: ...is is necessary to ensure proper cooling of the pump and prevent overheating In summmer months or dry hot climates water evaporates very quickly so it may be necessary to check the water level every d...

Page 7: ...ination which may clog the pump Disconnect the pump from the power source and empty the water from the fountain Use any gentle household cleanser and a soft brush or cloth to clean the fountain Avoid...

Page 8: ...o decrease water flow The pump operates but the water flow is uneven or non existent and the pump makes noise Check the impeller assembly for wear Remove the front cover and regulator impeller plate a...

Page 9: ...Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for future use...