CAUTION:

 Keep outdoor gas appliance area 

clear and free from combustible materials,
gasoline and other flammable vapors and liquids.

CAUTION:

 

Do NOT obstruct the flow of combustion 

and ventilation air.

CAUTION:

 

Check and clean burner/venturi tubes for

insects and insect nests. A clogged tube can lead to a fire.

LIGHTING

1. Make sure all labels, packaging and protective films have been removed from the out

2. Remove cover and burner lid (if applicable) before opera

for obstructions of airflow to the burner. 

    Spiders, insects and webs can clog the burner/venturi tube. A clogged burner tube can lead to a fire.

3. Control knob must be in the “OFF” position.

4. To ensure proper function, the screen on the pilot housing should not be covered by lava rocks.

5. Connect LP gas tank per steps 1 and 2 in the "Operation" section.

6. Turn LP gas tank valve to “OPEN”.

7. Push and hold the flame ignitor to create sparks within the electrode; and continue to hold.

8. Push in the control knob and turn to the “ON” position. Keep holding down the control knob to allow gas to flow for 20 seconds.

9. After 20 seconds, release and turn control knob counterclockwise to adjust flame to desired height.

10. If ignition does not occur in 20 seconds turn burner control knob to “OFF”, wait five minutes, fan with a newspaper or 

      magazine, and repeat lighting procedure.

CAUTION:

WARNING: 

NEVER light the burner with 

CAUTION:

 

Failure to follow these instructions   

could cause a fire or an explosion which can cause
death, serious bodily injury or damage to property.

OFF

ON

 

Summary of Contents for 1005 045 453

Page 1: ...ucts designed to enhance your home Visit us online to see our full line of products available for your home improvements needs Thank you for choosing Hampton Bay BOWBRIDGE STEEL LP FIRTPIT Questions p...

Page 2: ...on and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference If you are asse...

Page 3: ...te gas supply to this unit Only use propane gas for this unit Converting this unit to natural gas is dangerous This conversion kit shall be installed by a qualified service agency in accordance with t...

Page 4: ...e table when in use will become too hot to touch Do not touch hot surfaces until the unit has cooled unless you are wearing protective gear such as insulated pot holders or heat resistant gloves or mi...

Page 5: ...NOT store in a building garage or any other enclosed area Never store your LP gas tank where temperatures can reach over 125 F 52 C Do not store the LP gas cylinder in direct sunlight or near a source...

Page 6: ...replacement of the hose call the service center at 1 855 HD HAMPTON Use only replacement parts from the manufacturer b Inspect the seal inside the CGA No 791 service valve on the LP gas cylinder when...

Page 7: ...oard HARDWARE INCLUDED NOTE More than one person may be required to assemble this product NOTE Hardware not shown to actual size M6X15 Combination bolt M6X12 Countersunk bolt 22 1 1 1 AA AA BB BB Plas...

Page 8: ...ort Lava Rocks Burner Bowl 1 1 1 I I J J K K Burner ring 1 L L Pilot housing Manual Electric lgniter Control Knob 1 1 1 M M N N O O Regulator Hose 1 P P Part Description Quantity WARNING Failure to po...

Page 9: ...table top B using M6X15 combination bolts AA Do not tighten the bolts at this step NOTE Pay attention to the direction of control knob it must place as below direction shown HAMPTONBAY COM Please con...

Page 10: ...inued 2 CONNECTING THE SIDE PANEL Attach the side panel F to the table top B using M6X15 combination bolts AA Do not tighten the bolts at this step C D E E F AA NOTE Loosely tighten all the bolts usin...

Page 11: ...BE Attach the limit tube H to the leg C D using M6X15 combination bolts AA Do not tighten the bolts at this step HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance NOTE Loosely tigh...

Page 12: ...Attach the tank support I to the leg C D E using M6X15 combination bolts AA Do not tighten the bolts at this step HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance NOTE Loosely tig...

Page 13: ...ttach the door G to the leg C using an M6X12 countersunk bolt BB and plastic washers CC as shown below HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance NOTE Tighten all the bolts...

Page 14: ...14 Assembly continued 6 ATTACH THE KNOB TO THE DOOR Attach the knob DD to the door C shown below HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance C DD...

Page 15: ...n place fully tighten all the bolts using the hex wrench EE Place the lava rocks J into the burner bowl K HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance CAUTION To ensure proper...

Page 16: ...to burner bowl until it has cooled down HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance A B Make sure to remove the burner lid before lighting WARNING Surfaces on the fire table...

Page 17: ...D CONTROL KNOB Insert the AAA battery FF and control knob N into the manual electric igniter N and twist the button cover on to igniter housing Do not over tighten HAMPTONBAY COM Please contact 1 855...

Page 18: ...etainer bolt by turning counter clockwise on CAUTION LP gas tank must be properly disconnected and removed prior to moving this Secure tank by turning LP gas tank retainer bolt clockwise until tight H...

Page 19: ...there is no debris caught in the head of the LP gas tank head of the regulator valve or in the head of the burner ports Connect the regulator hose assembly to tank by turning knob clockwise until it s...

Page 20: ...ve is CLOSED Disconnect regulator hose assembly from LP gas by turning knob conter clockwise until it is loose Place the protective cap cover on the LP gas tank and store it outdoors in a well ventila...

Page 21: ...proper installation Make sure the regulator hose and valve connections are securely fastened to the burner and the tank Failure to follow those instructions can serious injury or property cause death...

Page 22: ...ANK SECTION Turn LP gas tank valve to OPEN a If any bubbles appear turn LP gas tank valve to CLOSED reconnect and re test b If you continue to see bubbles after several attempts turn LP gas tank valve...

Page 23: ...23 Operation continued 7 CLOSE THE DOOR Close the door Now the fire table is complete and ready to use HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance...

Page 24: ...3 Control knob must be in the OFF position 4 To ensure proper function the screen on the pilot housing should not be covered by lava rocks 5 Connect LP gas tank per steps 1 and 2 in the Operation sec...

Page 25: ...ble Before Each Use 1 Ensure the outdoor fire table area is clear and free from any combustible materials gasoline and other flammable vapors and liquids 2 Do not obstruct the flow of the combustion o...

Page 26: ...remains the customer s responsibility for freight and packaging charges to and from our service center This warranty does not cover commercial use hardware acts of nature fire freezing and abusive us...

Page 27: ...5 minutes for gas to clear 3 Follow Checking for Leaks section There is no gas flow The coupling nut and regulator are not fully connected An obstruction of the gas flow 1 Clear the burner venturi tub...

Page 28: ...en burning in cold weather temperature below 50 F 10 C Ice has built up on the outside of the LP gas tank because the vaporization process is too slow 1 Turn off per Turning Off section 2 Replace with...

Page 29: ...problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for fu...

Reviews: