1. This fire table comes equipped with a standard LP gas hose and regulator including the appliance side connection for a CGA

No. 791 Cylinder Connection Device. The LP gas hose and regulator supplied with this fire table must be used. Only a hose and
regulator specified by manufacturer can be used for replacement.

a. The CGA No. 791 connection incorporates a magnetic flow limiting device that acts to limit the flow of gas if a leak is

detected between the regulator and the burner valve.

b. If the burner valve is open prior to the LP gas cylinder service valve being opened, the connection will interpret this

free flow of gas to be a leak.

c. The connection safety feature will reduce gas flow from the regulator to the appliance to a minimal level.
d. Be sure that the burner control valve is closed prior to opening the LP gas cylinder service valve to ensure that the

connection flow limiting device is not triggered mistakenly.

e. If the connection flow limiting device is triggered mistakenly, close the LP gas cylinder service valve and the burner

valve, wait 10 seconds to allow the device to reset, open the cylinder service valve, then open the burner valve and light
the fire table as per lighting instructions.

2. Be sure to protect the hose from any hot surfaces. Serious danger may result if the hose contacts any hot surface.
3. Regular maintenance of the hose and regulator:

a. Inspect the hose before each use of the fire table. If the hose shows signs of cracks, abrasions, cuts or damage of any

kind, do not operate the appliance. Fix or replace the hose as required before using the appliance. For assistance with
repair or replacement of the hose, call the service center at 1-855-HD-HAMPTON. Use only replacement parts from the
manufacturer.

b. Inspect the seal inside the CGA No. 791 service valve on the LP gas cylinder when replacing the cylinder or at least once

per year. If there is any indication of damage, have the seal replaced by a certified gas dealer before operating
the appliance.

4. Do not use tools to tighten the CGA No. 791 connection nut onto the LP gas cylinder service valve. Hand tighten only.
5. Be careful to not cross the threads on the connection when tightening the CGA No. 791 connection onto the LP gas cylinder

service valve.

6. “Leak Test” should always be performed after attaching the connection to the LP gas cylinder service valve. See “Checking

for Leaks” section of this manual in Step 6, page 21.

7. Connection instructions are on pages 17-18 (Steps 2–3 in the “Operation” section).

LAVA ROCKS WARNING

1. Lava rocks may have sharp edges. Wear safety glasses and gloves when handling.
2. If changing or substituting the lava rocks with other media, use lava rocks/pumice stones/glass shards/glass beads available

from your local authorized dealer/distributor.

3. Pour the lava rocks evenly into the burner area (with the exception of the screen, if applicable). The lava rocks should be 1/2 to

1 in. (1.2 to 2.5 cm) above the burner.

4. IMPORTANT: Do not exceed a height of 1 in. (2.5 cm) above the burner when placing lava rocks or other media. Ensure no media

covers the igniter screen. Store any excess lava rocks in a safe location.

5. Keep away from the unit for the first 20 minutes after igniting your unit for the first time, as lava rocks/pumice stones/glass

beads could pop out and cause injury. Should any rocks pop out, discard them.

6. Always ensure that lava rocks/pumice stones/glass shards/glass beads are completely dry before use. Failure to do so will

cause them to crack or pop.

Important Safety Information (continued)

Summary of Contents for 1005 045 453

Page 1: ...ucts designed to enhance your home Visit us online to see our full line of products available for your home improvements needs Thank you for choosing Hampton Bay BOWBRIDGE STEEL LP FIRTPIT Questions p...

Page 2: ...on and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference If you are asse...

Page 3: ...te gas supply to this unit Only use propane gas for this unit Converting this unit to natural gas is dangerous This conversion kit shall be installed by a qualified service agency in accordance with t...

Page 4: ...e table when in use will become too hot to touch Do not touch hot surfaces until the unit has cooled unless you are wearing protective gear such as insulated pot holders or heat resistant gloves or mi...

Page 5: ...NOT store in a building garage or any other enclosed area Never store your LP gas tank where temperatures can reach over 125 F 52 C Do not store the LP gas cylinder in direct sunlight or near a source...

Page 6: ...replacement of the hose call the service center at 1 855 HD HAMPTON Use only replacement parts from the manufacturer b Inspect the seal inside the CGA No 791 service valve on the LP gas cylinder when...

Page 7: ...oard HARDWARE INCLUDED NOTE More than one person may be required to assemble this product NOTE Hardware not shown to actual size M6X15 Combination bolt M6X12 Countersunk bolt 22 1 1 1 AA AA BB BB Plas...

Page 8: ...ort Lava Rocks Burner Bowl 1 1 1 I I J J K K Burner ring 1 L L Pilot housing Manual Electric lgniter Control Knob 1 1 1 M M N N O O Regulator Hose 1 P P Part Description Quantity WARNING Failure to po...

Page 9: ...table top B using M6X15 combination bolts AA Do not tighten the bolts at this step NOTE Pay attention to the direction of control knob it must place as below direction shown HAMPTONBAY COM Please con...

Page 10: ...inued 2 CONNECTING THE SIDE PANEL Attach the side panel F to the table top B using M6X15 combination bolts AA Do not tighten the bolts at this step C D E E F AA NOTE Loosely tighten all the bolts usin...

Page 11: ...BE Attach the limit tube H to the leg C D using M6X15 combination bolts AA Do not tighten the bolts at this step HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance NOTE Loosely tigh...

Page 12: ...Attach the tank support I to the leg C D E using M6X15 combination bolts AA Do not tighten the bolts at this step HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance NOTE Loosely tig...

Page 13: ...ttach the door G to the leg C using an M6X12 countersunk bolt BB and plastic washers CC as shown below HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance NOTE Tighten all the bolts...

Page 14: ...14 Assembly continued 6 ATTACH THE KNOB TO THE DOOR Attach the knob DD to the door C shown below HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance C DD...

Page 15: ...n place fully tighten all the bolts using the hex wrench EE Place the lava rocks J into the burner bowl K HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance CAUTION To ensure proper...

Page 16: ...to burner bowl until it has cooled down HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance A B Make sure to remove the burner lid before lighting WARNING Surfaces on the fire table...

Page 17: ...D CONTROL KNOB Insert the AAA battery FF and control knob N into the manual electric igniter N and twist the button cover on to igniter housing Do not over tighten HAMPTONBAY COM Please contact 1 855...

Page 18: ...etainer bolt by turning counter clockwise on CAUTION LP gas tank must be properly disconnected and removed prior to moving this Secure tank by turning LP gas tank retainer bolt clockwise until tight H...

Page 19: ...there is no debris caught in the head of the LP gas tank head of the regulator valve or in the head of the burner ports Connect the regulator hose assembly to tank by turning knob clockwise until it s...

Page 20: ...ve is CLOSED Disconnect regulator hose assembly from LP gas by turning knob conter clockwise until it is loose Place the protective cap cover on the LP gas tank and store it outdoors in a well ventila...

Page 21: ...proper installation Make sure the regulator hose and valve connections are securely fastened to the burner and the tank Failure to follow those instructions can serious injury or property cause death...

Page 22: ...ANK SECTION Turn LP gas tank valve to OPEN a If any bubbles appear turn LP gas tank valve to CLOSED reconnect and re test b If you continue to see bubbles after several attempts turn LP gas tank valve...

Page 23: ...23 Operation continued 7 CLOSE THE DOOR Close the door Now the fire table is complete and ready to use HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance...

Page 24: ...3 Control knob must be in the OFF position 4 To ensure proper function the screen on the pilot housing should not be covered by lava rocks 5 Connect LP gas tank per steps 1 and 2 in the Operation sec...

Page 25: ...ble Before Each Use 1 Ensure the outdoor fire table area is clear and free from any combustible materials gasoline and other flammable vapors and liquids 2 Do not obstruct the flow of the combustion o...

Page 26: ...remains the customer s responsibility for freight and packaging charges to and from our service center This warranty does not cover commercial use hardware acts of nature fire freezing and abusive us...

Page 27: ...5 minutes for gas to clear 3 Follow Checking for Leaks section There is no gas flow The coupling nut and regulator are not fully connected An obstruction of the gas flow 1 Clear the burner venturi tub...

Page 28: ...en burning in cold weather temperature below 50 F 10 C Ice has built up on the outside of the LP gas tank because the vaporization process is too slow 1 Turn off per Turning Off section 2 Replace with...

Page 29: ...problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for fu...

Reviews: