3.4 Command Trigger mode
In this mode, the reader starts to read the code when it receives the scan command sent by the host (ie
bit0 of flag 0x0002 is written to "1"), and stops reading after the reading succeeds in outputting the message or
the reading time of single reading.
Command trigger mode
Note: In the command triggering mode, the serial port triggering the scan command is: 7E 00 08 01 00 02
01 AB CD; Upon receiving the trigger command, the reader will output seven bytes of response message and
start the scan synchronously Information content: 02 00 00 01 00 33 31).
Single reading time
In command triggered reading mode, this parameter refers to the maximum length of time that the reader
is allowed to continue acquisition recognition before the reading is successful. Single reading time length setting
range of 0.1 ~ 25.5 seconds, step 0.1 seconds. When set to 0, the reading time is infinite. The default duration
is 5.0 seconds.
1000ms
3000ms
* 5000ms
Infinitely long