Only the Center section is transmitted
Example: When the decoding information is "12345678900123ABC", the middle four bytes "0123"
1. Check the character table to get the decimal data "10", "3" corresponds to the hexadecimal characters were
"0A", "03"
2. Check whether the setting code is on. If it is not on, please scan the setting code "On" (see section 1.5.2)
3. Scan "Modified cut length N" setting code
4. Scan data setting code "0", "3"
5. Scan "Save" setting code
6. Scan "Modify before cut length M" setting code
7. Scan the data setting code "0", "A"
8. Scan the "Save" setting code
9. Scan the "Center section only" setting code
7.6 RF information
RF (Read Fail) message refers to the reader in some modes, you want to read the code is unsuccessful,
the user output some information freely defined, the user or program detects this information and make the
appropriate adjustments or operations.
Send RF information
* Not send RF information
Modify RF information
Scan the "Modify RF Information" setting code, and combine the scan data setting code. The user can
modify the RF information content, use two hexadecimal values for each RF character, RF up to 15 characters,
hexadecimal Conversion table can refer to the appendix.
Modify RF information
Example: Modify User Defined RF Information to "FAIL"
1. Check the character table to get "FAIL" four characters hexadecimal value: "46", "41", "49", "4C"
2. Check whether the setting code is on. If it is not on, please scan the setting code "on" (see section 1.5.2)
3. Scan "modify RF information" setting code
4. Scan the data setting codes "4", "6", "4", "1", "4", "9", "4", "C"
5. Scan "Save" setting code
Summary of Contents for HBCS2D100US