8.3 Ethernet interface parameters at the host (PC)

8.3.1 Parameters under Windows XP

Reference! In order to be able to accomplish the following 
parameters, you have to be announced at the host concerned 
(PC) as “administrator“, or you have to be member of the user 
group “administrators“ (e.g. in the network).

To preset the interface parameters of the Ethernet LAN inter-
face at the host PC please go to “Start“ menu and select under 
the menus “Control Panel“ 

>

 „Network connections“ the menu 

“Local Area Connection“. In the new opened window to “Local 
Area Connection Properties“ please click on “Internet Protocol 
(TCP/IP)“ and click on “Properties“.

 

In the new opened window “Internet Protocol (TCP/IP) Proper-
ties“ please click on “Alternative Confi guration“ and select the 
option “User confi gured“ for the manual preset of the network 
parameters. In the input fi eld „IP address:“ please enter from 
your (or from a network administrator specifi ed) IP address 
for the PC (e.g. 192.168.10.2). In the input fi eld “Subnet mask“ 
please enter from your (or from a network administrator spe-
cifi ed) subnet mask for the PC (e.g. 255.255.255.0). In the input 
fi eld “Default gateway“ please enter your (or from a network 
administrator specifi ed) IP address of the gateway (e.g. the IP 
address of the router of its LAN network). With a direct con-
nection of oscilloscope and host (PC) over a network cable this 
input is optional.

Reference! The preset IP addresses at the oscilloscope and at 
the host (PC) have to be different and be in the same subnet (ex.: 
oscilloscope 192.168.010.010, PC 192.168.010.002, with subnet 
mask 255.255.255.000).

 

If you attached the oscilloscope and the host (PC) to a network 
with existing DHCP server (with activated DHCP function), 
the presets for IP address, subnet mask and gateway of the 
existing DHCP server are assigned dynamically automatically. 
In this case you don’t need the described manual presets of 
IP address, subnet mask and gateway. In the opened window 
“Internet Protocol (TCP/IP) Properties“ please click on „Alter-
nate Confi guration“ and select the option „Automatic private 
IP address“.

 

After the presets you confi rm the inputs please click „OK“.

          E t h e r n e t  c o n f i g u r a t i o n

Summary of Contents for HO730

Page 1: ...E T H E R N E T U S B I N T E R F A C E H O 7 3 0 Installation guidelines English...

Page 2: ...nditions in individual cases HAMEG Instruments GmbH KONFORMIT TSERKL RUNG DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE DECLARACI N DE CONFORMIDAD Hersteller Manufacturer Fabricant Fabricante HA...

Page 3: ...ruction 5 5 1 Removing the existing interface 5 5 2 Fitting the interface HO730 5 6 Interface Selection 6 7 USB Driver Installation 7 7 1 Installation under Windows XP 7 8 Ethernet con guration 9 8 1...

Page 4: ...e is equipped with a Type A USB female connector For direct connection with a host controller or an indirect con nection via a USB hub a USB cable is required equipped with Type B male connector one e...

Page 5: ...of the oscilloscope to equalise potentials between oscilloscope and your body Maintain this connection during the tting removing Only touch the interface at its mounting panel 5 1 Removing the existi...

Page 6: ...activated With the activating of Ethernet the menu option Parameter also ap pears additional in the Readout which the Ethernet interface parameter settings made possible see section 8 Reference The ho...

Page 7: ...splayed Only in this case the USB Driver must be installed The USB Driver is located in the directory HO730_D2xx_Dri ver 7 1 Installation under Windows XP 7 1 1 Please choose No not this time and clic...

Page 8: ...7 1 3 4 After the selected path is displayed click Next 7 1 4 Thereafter the Hardware Installation window is displa yed showing a warning to continue the installation procedure As this warning is irr...

Page 9: ...s is used as network IP address and the last IP address is used as Broadcast IP address in each case two IP addresses have to be taken off from the number of possible host addresses see table 1 Privat...

Page 10: ...on control to the desired value The menu option Save in the Readout saves the preset interface parameters by the oscilloscope and or determined automatically after press the menu option Save with acti...

Page 11: ...he input eld Subnet mask please enter from your or from a network administrator spe ci ed subnet mask for the PC e g 255 255 255 0 In the input eld Default gateway please enter your or from a network...

Page 12: ...the host PC If the connection over further network elements e g switches routers network servers etc is used examine if necessary these further connections as well as the presets of the appropriate n...

Page 13: ...e found in the Internet www hameg com for downloading and updating your PC The path of the software is Products Oscilloscopes oscilloscope type Software Firmware below the oscilloscope picture Softwar...

Page 14: ...14 Subject to change without notice...

Page 15: ...15 nderungen vorbehalten A p p l i c a t i o n...

Page 16: ...riestra e 6 A Rohde Schwarz Company D 63533 Mainhausen registered trademark Tel 49 0 61 82 800 0 DQS Certi cation DIN EN ISO 9001 2000 Fax 49 0 61 82 800 100 Reg Nr 071040 QM sales hameg de authorized...

Reviews: