24
Subject to change without notice
C o n t r o l s a n d R e a d o u t
Menu items
Depending on the operating mode (Yt or XY) this menu will offer
various cursor measuring functions which will affect the cursor
lines and their positions.
4.1 Meas.(uring) Type
If this function is activated, the INTENS knob
2
can be used
for measurement selection. In most cases the corresponding
unit will be automatically displayed. The measuring modes are
self explanatory.
4.2 Unit
In the modes ”Ratio X“ and ”Ratio Y“ the INTENS knob symbol
will be shown in addition to a unit, as it may then be used to
change the unit.
4.2.1
” rat ” (ratio), display of ratios
In this mode the ratios of duty cycles or amplitudes may be
determined with the CURSORS. The distance between the long
CURSOR lines is equal to 1.
4.2.2
” % ” (percent), display of percentages
The distance between the long CURSOR lines is equal to 100%.
The result will be determined by the distance of the short
auxiliary cursor line to the long reference line (lower, left re-
spectively), with a negative sign if appropriate.
4.2.3
” ° ” (degree), measurement of degrees
The distance between the long CURSOR lines is equal to 360
degrees and must be exactly as long as a signal period. The
measurement result will be determined from the distance
between the reference line to the short auxiliary cursor line,
with a negative sign If appropriate. For further information
please consult ”Measurements of phase differences in dual
channel mode (Yt)“ in the section ”First time operation and
pre settings“.
4.2.4
”
π
”
One period of a sine wave is equal to 2
π
, hence the distance
between the two long CURSOR lines must be set to one peri-
od. If the distance between the reference line and the short
CURSOR line equals 1.5 periods, ”3
π
“ will be displayed. If the
short cursor line is to the left of the reference line a negative
sign will be shown.
4.3 Respect
It may be necessary to determine for which signal channel the
CURSOR measurements are valid. This is done by showing the
INTENS knob signal next to the channel number. After selection
of the signal source, the CURSOR lines must then be positioned
to the signal displayed by this channel.
4.4 Off (Cursors Off)
Pressing the function key “Off” switches the “Cursors” menu,
the cursor lines and the cursor measurement results off.
If only the displayed “Cursors” menu is to be switched off, press
the MENU OFF pushbutton
37
.
5
SAVE/RECALL
(pushbutton)
This pushbutton will open up a menu.
Under SAVE/RECALL the current instrument settings may be
saved or settings saved earlier recalled. There are 9 non volatile
memories available.
5.1 Saving the actual settings
Upon pressing the pushbutton the menu ”Front Panel“ will be
accessed. Pressing the function key “Save” shows one func-
tion key for page selection and numbered memories allocated
to function keys. Pressing a memory function key stores the
current instrument settings in the selected memory location
number .
5.2 Recall the actual settings
The menu ”Front Panel“ will be displayed after pressing the
SAVE/RECALL pushbutton. Pressing the function key “Recall”
shows one function key for page selection and numbered me-
mories allocated to function keys. Pressing a memory function
key causes loading of the stored settings.
VAR
VAR
VAR
x10
FOCUS
TRACE
VOLTS / DIV
VAR
VOLTS / DIV
VAR
TIME / DIV
VAR
X-POS
INTENS
!
LEVEL A/B
MENU
AUX
AUXILIARY INPUT
HORIZONTAL
INPUTS
1M
Ω
II13pF
max
250 Vp
CAT I
!
CAT I
!
DELAY
TRACE
SEP
CH 1/2
CURSOR
SAVE/
RECALL
AUTOSET
SETTINGS
HELP
POSITION 1
POSITION 2
VERT/XY
HM2005-2
ANALOG
OSCILLOSCOPE
200 MHz
TRIGGER
MODE
FILTER
SOURCE
TRIG
’
d
NORM
HOLD OFF
AUTO
MEASURE
CURSOR
MEASURE
TRIG. EXT. / Z-INP.
CH 1
CH 2
X-INP
CH 1
CH 2
HOR
MAG
1M
Ω
II
13pF
max
100 Vp
5 V
1 mV
5V
1 mV
0.5s
20ns
CH I MENU
AC/DC/50
Ω
GND
50
Ω
/ 1 M
Ω
INVERT
ON / OFF
VARIABLE
ON / OFF
PROBE
1 : 1 / 10 / 100
CH I: 500 mV
POWER
POWER
PROBE
ADJ
A N A L O G S C O P E
Instruments
MENU
MENU
OFF
OFF
COMP.
TESTER
1
2
3
4
5
6
7
8
15
22
23
19
20
16
17
24
18
21
25
26
9
11
10
13
12
14
37
27
30
28
29 31
32
33
36
35
34