Hama 104989 Operating Instruction Download Page 7

12

13

Remove back cover

Step 4:

You will hear a long beep and the zone LED stops fl ashing. The sensor
is now programmed to the Control Panel.

Note: 

You may program up to 4 sensors to one zone.

Zone 4 is an alert zone, sensors in this zone is for alert purpose ONLY
and will not trigger the alarm.

3. PROGRAMMING

Set the temperature unit (Fahrenheit / Celsius)

The temperature sensor can operate and display temperature in Fahrenheit 
or Celsius. To select the desire unit, open the back cover you will see a 
jumper connector for “C/F” as shown below. To select Fahrenheit, place a 
jumper on this “C/F” connector. To select Celsius, remove the jumper from 
this connector.

Note: 

The temperature sensor can monitor the temperature within this

range: 157°F (69°C) to -3°F(-19°C).

In order for the temperature sensor to monitor specifi c temperatures, you 
can program the upper and lower limits. When the actual temperature 
exceeds either limit, it will send a signal to the control panel. To program the 
temperature limits, follow the instructions below:

To set the upper temperature limit:

1.  Press and hold the “HI” button.
2.  While holding on to the “HI” button, press “UP” or “DOWN” to select the  
  upper temperature limit.
3.  Release all buttons after setting the upper temperature limit. 

To set the lower temperature limit:

1.  Press and hold the “LO” button.
2.  While holding on to the “LO” button, press “UP” or “DOWN” to select  the  
  lower temperature limit.
3.  Release all buttons after setting the lower temperature limit.

After programming the temperature limits, you may test its function.

You must enable either the upper limit, or lower limit, or both limits in order 
for the temperature to alert the control panel.

To enable the Upper Limit, press „HI”, the display will show „HI”, that 
indicates the Upper Limit is enabled. To enable the Lower Limit, press „LO”, 
the display will show „LO”, that indicates the Lower Limit is enabled. If both 
„HI” and „LO” are shown, that means both limits are enabled. When „HI” or 
„LO” button is pressed, it will also display the current setting or the upper or 
lower limit. When the actual temperature is above the upper limit or below 
the lower limit, the temperature sensor will send a
signal to the control panel.

00104989man_de_en_fr.indd   12-13

00104989man_de_en_fr.indd   12-13

02.06.10   08:14

02.06.10   08:14

Summary of Contents for 104989

Page 1: ...00104989man_de_en_fr indd 2 3 00104989man_de_en_fr indd 2 3 02 06 10 08 14 02 06 10 08 14 ...

Page 2: ...ör Zur Einrichtung des Temperaturmelders folgen Sie den nachstehenden Anweisungen 2 Koppeln des melders mit dem Bedienfeld der AS 200 Serie Damit der Melder ordnungsgemäß mit dem Bedienfeld kommunizieren kann muss der Melder für das Bedienfeld programmiert sein Folgen Sie den nachstehenden Kurzanweisungen oder den ausführlichen Anweisungen in der Benutzeranleitung der AS 200 Series um den Melder f...

Page 3: ...rte über bzw unterschreitet wird ein Signal an das Bedienfeld gesendet Um die Grenztemperaturen festzulegen folgen Sie den nachstehenden Anweisungen So legen Sie den oberen Temperaturgrenzwert fest 1 Halten Sie die Taste HI Höchstwert gedrückt 2 Drücken Sie bei gedrückter HI Taste die Taste UP oder DOWN um den oberen Temperaturgrenzwert auszuwählen 3 Nachdem Sie den oberen Temperaturgrenzwert fest...

Page 4: ...ustisches Warnsignal Das Bedienfeld hört auf zu piepen und zu blinken sobald die Temperatur auf einen zulässigen Wert zurückgekehrt ist Wenn z B als oberer Grenzwert 40 C programmiert sind wird ein Signal an das Bedienfeld gesendet sobald die Temperatur 40 C überschreitet Auch wenn die Temperatur unter 40 C zurückgeht wird dies jedoch nicht sofort gemeldet sondern erst wenn sie diesen Wert mindest...

Page 5: ...t auf eine Aktivierungsprüfung bei verringertem Abstand reagieren tauschen Sie die Batterie des Melders aus Wenn sich mehrere Melder in der betreffenden Zone befinden müssen Sie eventuell die Funktionsfähigkeit der Melder einzeln testen um herauszufinden wo die Störung liegt Austauschen der Batterien Der Temperaturmelder wird mit zwei Lithiumbatterien vom Typ CR 2032 betrieben Bei niedrigem Ladest...

Page 6: ... mounting accessories Please follow the instructions below to set up the temperature sensor 2 Learn Sensor to AS 200 Series Control Panel In order for the sensor to communicate with the control panel properly the sensor must be programmed to the control panel Follow the brief instructions below or refer to the detail instructions from the AS 200 Series User s Instructions to program the sensor to ...

Page 7: ...upper temperature limit 1 Press and hold the HI button 2 While holding on to the HI button press UP or DOWN to select the upper temperature limit 3 Release all buttons after setting the upper temperature limit To set the lower temperature limit 1 Press and hold the LO button 2 While holding on to the LO button press UP or DOWN to select the lower temperature limit 3 Release all buttons after setti...

Page 8: ... built in temperature sensor An external probe can be used to measure outdoor temperature Temperature sensor must still be mounted indoor Refer to 5 INSTALLATION for further information 5 Installation The temperature sensor should be mounted onto the wall by 2 screws Follow the procedures below 1 Use a template to mark the location for the 2 screws correctly 2 Tighten the screws onto the wall half...

Page 9: ... condition the low battery LED indicator will flash When you see the low battery indication replace the batteries following the procedures below 1 Remove the screw on the back of the temperature sensor as shown 2 Rotate the battery compartment the batteries can be removed 3 Place the new batteries into the compartment pay attention on the polarity as indicated on the diagram 4 Tighten the screw Re...

Page 10: ...soires de montage Pour configurer l avertisseur de température suivez les instructions suivantes 2 Couplage du détecteur avec le panneau de commande série AS 200 L avertisseur doit être programmé pour le panneau de commande afin de pouvoir communiquer correctement avec ce dernier Suivez les instruction brèves suivantes ou les consignes complètes figurant dans le mode d emploi de la série AS 200 po...

Page 11: ...aleurs limites un signal est envoyé au panneau de commande Pour définir les températures limites suivez les instructions suivantes Définition de la valeur limite de température supérieure 1 Maintenez la touche HI valeur maximale appuyée 2 Tout en maintenant la touche HI appuyez sur la touche UP ou DOWN pour sélectionner la valeur limite de température supérieure 3 Lorsque vous avez défini la valeu...

Page 12: ...avertisseur est réinitialisé ou lorsque la température revient à une valeur autorisée Remarque si le commutateur d avertissement se trouve sur la position Clo che Chime un son de cloche unique retentit lors de chaque activation de signal Si le commutateur d avertissement se trouve sur OFF ARRET aucun signal d avertissement sonore ne retentit Le panneau de commande n émet plus aucun bip et cesse de...

Page 13: ...sseur du panneau de commande et essayez à nouveau de l activer Il est possible que l avertisseur soit installé trop loin du panneau de commande de sorte que la communication avec ce dernier soit perturbée Dans ce cas installez l avertisseur plus près du panneau de commande 4 Si malgré le rapprochement le panneau de commande ne réagit pas au contrôle de l activation remplacez la pile de l avertisse...