Instruction Manual PSx3xxSE
12
Name,
designation
IDN
Function
Byte
/
Type
Address
S-0-1040 sercosIII address
Min.: 1
Max.: 511
Default setting: 1
2 /
ud
Extended scale
for positional
data
P-0-0079 Used in combination with S-0-0079 to set "unlevel"
resolutions
Min.: 1
Max.: 10000
Default setting: 400
Changes only possible when at a standstill
4 /
ud
Drag error
correction factor
P-0-0159 Drag error correction is deactivated with the value 0.
Min.: 0
Max.: 10
Default setting: 0
Changes only possible when at a standstill
2 /
ud
Holding torque
at completion of
run
P-0-0822 Holding torque at completion of run
Unit: cNm
Min.: 0
Max.: **
Default setting: **
2 /
ud
Time for holding
torque at
completion of
run
P-0-0823 Time for holding torque at completion of run
Unit: cNm
Min.: 0
Max.: **
Default setting: **
2 /
ud
Adjustment
release
P-0-0900 Adjustment with value = 1 (only for PSE without brake)
Min.: 0
Max.: 1
Default setting: 0
2 /
ud
*
* The units and/or values are dependent on the scale (S-0-0079 and P-0-0079).
**
The value depends on the type of device (see following table).