Instruction Manual PSx3xxPL
6
Solid shaft:
The PSx3xxPL is mounted on the machine by fixing the solid shaft with coupling and
intermediate flange to the axis of the machine.
Never apply force to the housing cover, e.g., for supporting weight.
Driving the PSx3xxPL rearward is prohibited
(e.g. it’s not allowed to turn
the output shaft by an external force).
2.3
Pin assignment
For the supply voltage either a Binder series 713/763 (A-coded) round, 5-pin plug for
PSE and PSS devices or a 5-pin Harting plug with protective sleeve (HAN4A) for the
PSE34xx devices is located in the housing cover of the PSx3xxPL.
Two round 4-pin sockets, Binder series 825 (D-coded) are provided for connection to
the bus.
Supply voltage connector::
Round socket for bus:
Round plugr
Harting plug
(extrenal top view)
(extrenal top view)
(extrenal top view)
1
+24V motor
2
GND motor
3
+24V control unit
4 GND control unit
5 housing/pressure balance
1 TD+ (WH/GN, white/green)
2 RD+ (WH/OG, white/orange)
3 TD- (GN, green)
4 RD (OG, orange)
Due to the use of 4-pin sockets,
only four-wire cables should be
used.
To prevent the ingression of fluids into the PSW-housing during cooldown,
use a special cable with an airtube for pressure balancing of your PSW
Electrical grounding:
Next to the connecting plugs there is a M4 stud bolt. It is recommended to connect
the positioning system with a cable as short as possible to the machine base. The
minimum wire cross section therefor is 1.5mm².