Instruction Manual PSx3xxEIP
8
2.3. Disassembly
To remove the PSx3xx from the shaft, release the clamp (for versions with hollow
shaft the clamping ring) and pull the PSx3xx off the shaft. If possible, the PSx3xx
should only be pulled axially. Excessive bending back and forth can damage the
output shaft!
For versions with brake, it is essential to observe the instructions in sections 4.9 and
4.10!
2.4. Powering the device
For motor power use a single fuse with max. 3,5 A for each PSx3xx.
For motor power use a single fuse with max. 10 A for each PSE34xx.
For control power you can use a fuse with max. 2,0 A, so it is
possible to power up to 10 units parallel with one fuse.
It is strongly recommended to separate power cables to the PSx3xx
from other power cables that might have dangerous voltage.
It is strongly recommended to separate power cables to the
PSx3xxEI from other power cables that might have dangerous
voltage.
2.5. Pin assignment
Please take care that the mating connectors and the used cables
match the connectors in the PSx3xx and are mounted correctly,
in order to achieve the protection class.
2.5.1. Supply voltage connector
connector pattern
(external top view)
assignment
type
1. +24V motor
2. GND motor
3. +24V control unit
4. GND control unit
5. housing/pressure balance
PSE/PSS:
M12 (A-cod.); 5-pol.
PSW:
M12 (A-cod.);
4-pol. with airtube
1. +24V motor
2. GND motor
3. +24V control unit
4. GND control unit
5. housing/pressure balance
PSE34xx:
HAN4A, Harting
To prevent the ingression of fluids into the PSW-housing during
cooldown, use a special cable with an airtube for pressure
balancing of your PSW
In the special version with two M12 supply plugs, a maximum of 3
drives may be connected in series. Due to the maximum current
load of the connectors, the drives must not be positioned
synchronously.