halstrup-walcher KAL 84 Instruction Manual Download Page 1

 

KAL 84 Instruction Manual 

Document 7100.003554 

12/2015 

 

 

 

 

Instruction Manual 

KAL 84 Calibration Device 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

halstrup-walcher GmbH 

 

Stegener Straße 10 

D-79199 Kirchzarten 

Germany 

 

Phone: +49 (0) 76 61/39 63–0 

Fax:  +49 (0) 76 61/39 63–99 

 

E-Mail:  [email protected] 

Internet: www.halstrup-walcher.com 

 

 

Summary of Contents for KAL 84

Page 1: ...3554 12 2015 Instruction Manual KAL 84 Calibration Device halstrup walcher GmbH Stegener Stra e 10 D 79199 Kirchzarten Germany Phone 49 0 76 61 39 63 0 Fax 49 0 76 61 39 63 99 E Mail info halstrup wal...

Page 2: ...6 2 2 User interfaces 6 2 2 1 The 4 digit LCD 7 2 2 2 ON OFF 7 2 2 3 Backlighting 7 2 2 4 Analog output 7 2 2 5 Units of pressure 7 2 2 6 Pressure ports 7 2 2 7 Purge valves 7 2 2 8 Automatic zero po...

Page 3: ...le throughout the lifecycle of the instrument It must be provided to any individuals who assume responsibility for operating the instrument at a later date It must include any supplementary materials...

Page 4: ...y technical personnel who are appropriately trained and authorized by the operator of the facility may assemble the instrument and set up its electrical connections The instrument may only be operated...

Page 5: ...Symbols The symbols given below are used throughout this manual to indicate instances when improper operation could result in the following hazards WARNING This warns you of a potential hazard that c...

Page 6: ...strument ideal for use in assembling pressure transducers as it allows the transducers to be calibrated on site Use of the KAL 84 for quality assurance purposes e g as a transfer standard for test equ...

Page 7: ...e This feature allows the operator to toggle between 2 units of pressure e g Pa and mmHg A red LED indicates the units used 2 2 6 Pressure ports These ports are for connecting the test object to the K...

Page 8: ...strument is run from the power adapter even if the KAL 84 is not turned on Because the battery may or may not be fully charged upon delivery we recommend charging the battery before start up The KAL 8...

Page 9: ...A manual pump can quickly generate high levels of pressure which can destroy the instrument Caution is particularly advised when using instruments with low measurement ranges 5 Replacing the battery...

Page 10: ...t least once a year A halstrup walcher certificate of linearity or a calibration certificate from a testing facility accredited by Germany s National Accreditation Body DAkkS is available upon request...

Page 11: ...arting point setting 0 2 1 Digit for 1kPa measurement range 50kPa or 0 5 1 Digit Ambient conditions medium air all non aggressive gases operating temperature 10 C to 40 C storage temperature 10 C to 7...

Page 12: ...ontact with measurement medium beryllium bronze CuBe2 Araldite CY236 HY988 Mu metal nickel alloy Loctite 242e Brass CuZn39Pb3 Carbonyl iron Aluminum AlCuMgPb AlMg3 KEL FPM fluorinated rubber Silicon t...

Page 13: ...KAL 84 Instruction Manual 13 KAL 84 Instruction Manual 9 Dimension drawing 7100 003554_KAL84 doc 14 12 2015 Me...