PAGE 12
96812C (Rev. B - 6/04)
4590FR-FTN
The Following Items are included with
the 4590FR Fountain
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
Trouble Shooting
Insufficient Bubbler Flow:
Check that the shut-off valve is wide open. Verify
minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body.
Clean rubber orifice in flow control located below frost line in bushing between barb
fitting and valve.
No Flow:
Check for leaks in the air tubing going from the push button to the valve.
Make sure the air tubing compression nut is hand tight. Disconnect air tube from push
button. Place finger over air outlet. Push button to test diaphragm. Tighten diaphragm
cap screws. Replace diaphragm if necessary.
Continued Insufficient or Varied Height of Bubbler Flow:
Replace flow control.
Check for kinks in the tubing.
Remove the cleanout plug from the PVC column. Remove the valve assembly from
the PVC column by carefully pulling up on the strap and connecting tubing at the same
time. Pressure test the valve assembly for leaks. Check stream height from the
bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly from
this, adjust the screw on the regulator (Item 11, Page 10, Fig. 4). Clockwise adjustment
will raise stream and counter-clockwise adjustment will lower stream. For best
adjustment stream height should be approx. 1-1/2" (38mm) above the bubbler guard.
Replace the valve into the PVC column. Make sure the supply hose coils into the
bottom of the PVC column without any kinks and double check that the valve is
positioned fully at the bottom of the PVC column. Cap the PVC column.
Continuous Bubbler Flow:
Insure that push button is not obstructed and springs
back to normal position. Remove four screws which secure plastic diaphragm block to
valve body. Pull plastic and rubber diaphragm assembly out of valve body. Locate
tiny hole in rubber diaphragm just under lip of plastic part. Clean debris from this hole.
Inspect valve seat for grooves. If valve seat was OK and diaphragm hole was free
from debris, inspect rubber button located at center of floating steel disc in valve
diaphragm block assembly. If button is worn, turn disc over or replace it. If diaphragm
and seats are in good condition, stretch spring slightly. Spring is located behind floating
stainless steel plate. Insure that air bleed port on valve plastic block assembly is not
plugged.
100147140560
100322740560
101570540560
15013C
110544942550
110868642550
160270508640
170705042830
400942308640
45403C
45845C
56121C
600985451640
66346C
66461C
70683C
75588C
75589C
75565C
56092C
56123C
75539C
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
NS
NS
NS
NS
Drain Gasket
Gasket
Drain Gasket
Bubbler Tube Assy.
Set Screw #8-32 x .125
Socket Head Screw #10-24 x .75
Strainer Plate
Basin
Bubbler
Push Button Actuator
Drain Tube
Drain Elbow 1-1/4"
Drain Plug Assy.
Drain Tube
Fitting 1-1/4" x 1-1/4"
Union 1/4
Slip Joint Nut 1-1/4"
Gasket
Fitting - Double Male Connector
Poly Tubing - 1/4"
(Cut To Length) -To Bubbler
Poly Tubing - 1/8"
(Cut To Length) -To Actuator
Allen Wrench
ITEM NO.
PART NO.
PARTS LIST
DESCRIPTION
Included with
SanitaryFR1
Valve
32
31
28
34
35
29
27
22, 26
19
23
24
25
30
19
21
33
20
18