background image

PAGE 5

96812C (Rev. B - 6/04)

4590FR-FTN

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

2222 CAMDEN COURT

OAK BROOK, IL 60523

630.574.3500

PRINTED IN U.S.A.

* Includes items 28, 29, 30

30

29

28

Single Valve

Assy. (Item 27)

100147140560

100322740560

101449542550

101570540560

15013C

110544942550

110868642550

160270508640

170705042830

400942308640

45403C

45845C

50986C

55960C

56082C

56121C

600985451640

61313C

66346C

66461C

66719C

70683C

75565C

75588C

75589C

97243C

45787C

45788C

45789C

45790C

56092C

56123C

75539C

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

*27

28

29

30

NS

NS

NS

Drain Gasket

Gasket

Clamp - Hose

Drain Gasket

Bubbler Tube Assy.

Set Screw #8-32 x .125

Socket Head Screw #10-24 x .75

Strainer Plate

Basin

Bubbler

Push Button Actuator

Drain Tube

Regulator Holder

Pressure Fitting 1-1/4" To 3/4"

Regulator Nut

Drain Elbow 1-1/4"

Drain Plug Assy.

Regulator

Drain Tube

Fitting 1-1/4" x 1-1/4"

Tube Assy.

Union 1/4

Fitting - Double Male Connector

Slip Joint Nut 1-1/4"

Gasket

Single Control Valve System Complete

Single Control Valve Assy.

Rainbird Check Valve

Acorn Valve Assy.

Flow Control Fitting

Poly Tubing - 1/4" 

(Cut To Length) -To Bubbler

Poly Tubing - 1/8" 

(Cut To Length) -To Actuator

Allen Wrench

ITEM NO.

PART NO.

PARTS LIST

DESCRIPTION

The following items are included with

the 4590FR Fountain

Stream Height

Adjustment

Detail

15

21

Stream Height

Adjustment

13, 18

3

20

19

2

2

6, 10

11

12

1

9

16

24

25

7

8

17

22

4

14

23

26

20

5

Summary of Contents for 4590

Page 1: ...OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRIC...

Page 2: ...cap may be removed for servicing the valve 5 We recommend that the top of the column be flush or slightly above the top height of the concrete pad 6 You should test the unit before you backfill Simply...

Page 3: ...E BOTTOM COVER C 1 PVC DRAIN D PRESSURE FITTING 1 1 4 x 3 4 E CONNECTOR 1 1 4 TO 1 1 4 F 1 1 4 DRAIN TUBE G AIR CONTROL LINE H 1 4 WATER LINE J CONNECTOR FOR AIR CONTROL LINE SITE PREPARATION DETAIL F...

Page 4: ...STALLING 97243C SINGLE VALVE CONTROL ASSY 1 Prepare trench for water supply and waste drain lines if required by local codes The hole should be deep enough to accommodate the PVC column and 5 cubic fe...

Page 5: ...Gasket Clamp Hose Drain Gasket Bubbler Tube Assy Set Screw 8 32 x 125 Socket Head Screw 10 24 x 75 Strainer Plate Basin Bubbler Push Button Actuator Drain Tube Regulator Holder Pressure Fitting 1 1 4...

Page 6: ...column to fit desired bury depth Set PVC column in excavating pit 2 Lay drain lines and water supply lines Provide service shut off valve for maintenance Flush the water supply line before attaching t...

Page 7: ...PAGE 7 96812C Rev B 6 04 4590FR FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4590FR FTN WHEN USING THE SANITARYFR1 VALVE FIG 1...

Page 8: ...TED SITE PREPARATION DETAIL FOR THE 4590FR FTN WHEN USING THE SANITARYFR1 VALVE 1 1 4 DRAIN TUBE SUPPLIEDWITHFTN 1 1 2 DRAIN TUBE SUPPLIEDBYINSTALLER Detail A LEGEND A ACCESS PANEL B REMOVABLE BOTTOM...

Page 9: ...ert the 1 4 O D tube Label E into the 1 4 union provided with valve assembly Insert the 1 4 O D water line coming from the fountain into union Trim any excess length Step 4 Insert the 1 4 O D tube Lab...

Page 10: ...PAGE 10 96812C Rev B 6 04 4590FR FTN Detail B 13 15 2 14 5 3 11 4 12 5 6 6 5 13 15 10 See Detail B FIG 4 FIG 5 Stream Height Adjustment...

Page 11: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 NS PARTNO Hex Nut 3 8 16 Single Valve Regulator Holder Regulator Nut Poly Tubing 1 4 Cut To Length To Bubbler Poly Tubing 1 8 Cut To Length To Actuator Canist...

Page 12: ...ly hose coils into the bottom of the PVC column without any kinks and double check that the valve is positioned fully at the bottom of the PVC column Cap the PVC column Continuous Bubbler Flow Insure...

Reviews: