background image

When the HaloLog App is started, the Halo List screen will appear. The the top of the screen will show 
Found HaloFoggers” listed by the fogger’s individual serial number. Only HaloFoggers that are within 
range to the HaloLog App will be displayed. 

 

ACTION:

 Tap on a specific HaloFogger serial number to connect or ‘handshake’ to that fogger. 

 

You will automatically be taken to the Run Events Screen.

The bottom of screen displays “HaloLogs Stored on iDevice.”  This is a list of previously downloaded data 
logs identified by a fogger’s serial number. 

 

ACTION:

 Tap on specific HaloFogger serial number to view a previously downloaded run cycle 

 

log for review, editing or sharing. You will automatically be taken to the Run Events Screen to see   

 

this data.

Halo List Screen

The Run Events Screen shows a list of all Run ID’s that have been downloaded to the iDevice.

When a HaloFogger is connected to the iDevice the top row of the screen will display the Serial Number and 
total Run Time for that HaloFogger highlighted in GREEN.

The HaloLog data stored on the selected HaloFogger will download automatically after the Bluetooth® 
“handshake” has been established, which is indicated when the top row turns 

GREEN

.

Each Run Event is listed with specific information including: Run ID, Room, Building, Operator, Date, Cycle 
Start and Stop Time, and duration of run event.

The very bottom row of the screen (highlighted in light 

BLUE

) depicts how many records are kept on the 

HaloFogger and how many have been downloaded to the iDevice. 

 

ACTION

: Tapping on any run event will open the Run ID Screen where information on that run    

 

cycle can be edited. 

Run Events Screen

Button selections at the bottom of screen:

1.  

 

 

Tap to go to Email Screen to send data file by e-mail. 

2. 

 

  

Tap to return to Halo List Screen.

3.  

 

 

Tap to go to Utilities Screen to monitor data exchange between iDevice 

 

 

 

and HaloFogger. 

NOTE: Downloading of data will be interrupted if, during downloading, any input to the iDevice screen is 
initiated (tapping to select). Data downloading will resume the next time you re-connect.

Email

Utils

Halo List

HaloFogger®  Operation Manual_1911

Summary of Contents for HaloFogger STD 1911

Page 1: ...READ AND SAVE THESE INSTRUCTIONS Operation Manual 110V 220V STD 1911...

Page 2: ...treatment process Reservoir Door Funnel Port Status Indicator Light Walk Around Tour of the HaloFogger Status Indicator Light Displays the operational status of the Halo device Solid Green Indicates t...

Page 3: ...s when pouring disinfectant fluid into the device Avoid splashing or overfilling which could harm the user and or the device 12 Halosil International is not responsible for any injury or damage caused...

Page 4: ...pen a gallon 3 8 liters bottle of HaloMist Disinfectant and SLOWLY pour the contents into the funnel area AVOID SPLASHING 5 The fluid level indicator lights will illuminate as you pour to show how muc...

Page 5: ...ensor assume a waiting time of AT LEAST 110 MINUTES AFTER FOGGING 110 minutes is the minimum wait time Length of wait time increases with room size See time chart below Minimum Wait Times Fog Time Rec...

Page 6: ...om is not blocked c Position the dehumidifier if one is being used outside the smaller interior room centered in the doorway facing towards the fogger d Use Chemical Indicator Strips to ensure that th...

Page 7: ...d can be connected to the HaloFogger data logger via Bluetooth The HaloLog App does not need to be connected to a fogger before a treatment run is started The on board data logger captures all of the...

Page 8: ...will be displayed 4 To initiate a connection tap on any HaloFogger serial number displayed on the Halo List Screen When the connection is made the Run Events Screen will appear The top row of the scre...

Page 9: ...er and total Run Time for that HaloFogger highlighted in GREEN The HaloLog data stored on the selected HaloFogger will download automatically after the Bluetooth handshake has been established which i...

Page 10: ...vents will identified BILLABLE as a default Events that are not treatments a test run for example can be identified as NON BILLABLE These events will not appear in the downloadable CSV file but will b...

Page 11: ...address A keyboard will appear to enter address ACTION Tap to email data The iDevice s email screen will open to confirm message ACTION Tap SEND in upper right corner of screen to send message Back u...

Page 12: ...me to a HaloFogger 2 In the event that HaloLogs of the same HaloFogger have been downloaded to multiple devices If one user has made changes to the HaloLog for example added room building or operator...

Page 13: ...remove Step 3 Separate Parts Remove Main Bolt from Nozzle Insert Soak both parts in soap and water Rinse parts thoroughly with water Step 4 Reassemble Nozzle Carefully insert the Main Bolt back into...

Page 14: ...Reservoir Door is not in place Call Customer Service No power The power cord is not plugged in or the power source is not on Check to make sure that the power cord is plugged into both the fogger and...

Page 15: ...Nozzle Assembly 0750 000 includes retainer cap nozzle insert main bolt and O ring Re Order Number Part Part Number 110V HaloFogger US and Canada 0753 110 220V HaloFogger 0753 220 HaloMist All Purpose...

Page 16: ...of room being treated CAUTION PRECAUCION DO NOT ENTER ENTERINO Room Fogging in Progress Treatment Date Start Time Estimated Room Re entry Time Refer to HaloMist Use Instructions to determine room re...

Page 17: ...ion phone and email address purchase date from which HaloFogger was purchased and the unit s serial number Proof of purchase may be required If Halosil International determines that the fogger qualifi...

Page 18: ...uce infection rates at your facility by visiting www halosil com There you can find out more about the Halo Disinfection System download literature and case studies and find a distributor near you 91...

Reviews: